420
>
2300 - Underground Storage Tank Program
>
PR0231458
>
COMPLIANCE INFO_2023
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/5/2023 4:17:28 PM
Creation date
3/29/2023 10:21:47 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2023
RECORD_ID
PR0231458
PE
2361
FACILITY_ID
FA0001196
FACILITY_NAME
SAVE ON FUEL
STREET_NUMBER
420
Direction
W
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95337
APN
219-312-06
CURRENT_STATUS
01
SITE_LOCATION
420 W YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
51
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Underground Storage Tank <br />Overfill Prevention Equipment Inspection Report <br />Additional copies of this page may be attached. <br />Attach tank chart(s), measurements, calculations, and In-Tank Setup report(s) <br />Page 2 of 2 <br />6. OVERFILL PREVENTION EQUIPMENT DETAILS <br />Tank ID (one OPE per column) <br />Are both vent and tank riser piping <br />secondarily contained? <br />Yes <br />No <br />Yes <br />No <br />Yes <br />No <br />Yes <br />No <br />OPE Model <br />What is the OPE response when activated? <br />(Check all that apply.) <br />Shut off <br />Flow <br />Restricts <br />Flow <br />Audible <br />Alarm <br />Visual <br />Alarm <br />Shut off <br />Flow <br />Restricts <br />Flow <br />Audible <br />Alarm <br />Visual <br />Alarm <br />Shut off <br />Flow <br />Restricts <br />Flow <br />Audible <br />Alarm <br />Visual <br />Alarm <br />Shut off <br />Flow <br />Restricts <br />Flow <br />Audible <br />Alarm <br />Visual <br />Alarm <br />Are flow restrictors installed on vent piping <br />that may interfere with the OPE operation? <br />Yes* <br />No <br />Yes* <br />No <br />Yes* <br />No <br />Yes* <br />No <br />At what level in the tank is the OPE set to <br />activate? (Inches from bottom of tank) <br />What is the percent capacity of the tank at <br />which the OPE activates? <br />Is the OPE in proper operating condition to <br />respond when the stored substance <br />reaches the designated regulatory level? <br />Yes <br />No <br />Yes <br />No <br />Yes <br />No <br />Yes <br />No <br />7. SUMMARY OF TESTING RESULTS <br />OPE Inspection Results Pass <br />Fail <br />Pass <br />Fail <br />Pass <br />Fail <br />Pass <br />Fail <br />1 <br />8. COMMENTS <br />Describe all results marked “Fail” and each proposed remedy. <br />* Mark here if: <br />Flow restrictors interfere with overfill prevention and equipment repairs required. <br />Unleaded Regular OPE <br />Veeder Root <br />85.2" <br />95%
The URL can be used to link to this page
Your browser does not support the video tag.