San Joaquin County <br /> r % Environmental Health Department <br /> < 1868 E. Hazelton Ave. <br /> • Stockton, CA 95205 t <br /> cq�,FORa�� (209) 468-3420 1 a <br /> APPROVED WITH CONDITIONS ARCHITECTURE <br /> For conditions, I ase see approval letter dated: 9/10/18 <br /> _ [ Approved by: Date: Sep 10, 2018 <br /> - -" ARCHITECT <br /> NJ ASSOCIATES <br /> I I I I 1 22769 N BENDER ROAD <br /> ACAMPO CA 95220 <br /> LODI209.727.2040 <br /> I I www.njaarchitecture.com <br /> .71 <br /> All <br /> CLIENT <br /> �= JOE HADDAD <br /> BOWLING <br /> P.O.BOX 484 <br /> WALNUT GROVE CA 95690 <br /> LULL I 415.517.9686 <br /> ALLEY <br /> PROJECT <br /> LODGENERAL NOTES: ABBREVIATIONS: SYMBOL LEGEND: PROJECT DIRECTORY: SHEET INDEX. 302 302N BOWLING <br /> N SACRAMENTO STREET <br /> LODI CALIFORNIA 95240 <br /> 1. ON-SITE VERIFICATION OF ALL DIMENSIONS AND DETAILS SHALL BE THE RESPONSIBILITY OF THE GENERAL ABV ABOVE JST JOIST OWNER: CONTRACTOR: GENERAL SO.1 STRUCTURAL NOTES <br /> CONTRACTOR AND EACH SUBCONTRACTOR FOR HIS INDIVIDUAL WORK THE OWNER OR ARCHITECT SHALL ACOUS ACOUSTICAL JT JOINT ROOM NAME Joe Haddad TBD GO.0 COVER SHEET S1.1 FOUNDATION PLAN <br /> BE NOTIFIED IF ANY DISCREPANCIES ARE FOUND PRIOR TO COMMENCING ANY WORK THE RESPONSIBILITY ACT ACOUSTICAL CEILING TILE LAM LAMINATE ROOM NAME&REFERENCE NUMBER P.O.Box 691863 G1.0 AREA PLANS S2.1 CONCRETE TYPICAL DETAILS <br /> FOR WORK COMPLETED WITHOUT PROPER NOTIFICATION SHALL BE BORNE BY THE INDIVIDUAL CONTRACTOR AD AREA DRAIN LAV LAVATORY 101 Stockton,CA 95629 CIVIL: G1.1 FIRST LEVEL LIFE SAFETY PLAN S2.2 TYPICAL CONCRETE DETAILS <br /> INVOLVED. ADJ ADJUSTABLE LB(S) POUNDS DUSPIVA ENGINEERING G1.2 SECOND LEVEL LIFE SAFETY PLAN S3.1 FOUNDATION DETAILS <br /> 2. THE CONTRACT DOCUMENTS INDICATE THE EXTENT AND APPROXIMATE LOCATION OF ELEMENTS OF THE AFF ABOVE FINISH FLOOR LDG LANDING CONTACT: PO Box 845 Lodi,CA 95241 G2.0 SIGNAGE DETAILS S3.2 FOUNDATION DETAILS <br /> BUILDING AND SITE.ALL CONDITIONS,LOCATIONS,DEVICES AND ELEMENTS SHALL BE VERIFIED BYTHE ALT ALTERNATE LT LIGHT JOE HADDAD Office:209-333-2049 <br /> CONTRACTOR PRIOR TO COMMENCING THE WORK ALUM ALUMINUM MAX MAXIMUM M1.1 PARTITION TYPE REFERENCE NUMBER hitech300@gmail.com G3.0 ACCESSIBILITY DETAILS S3.3 STRUCTURAL CANOPY DETAILS <br /> 3. ALL WORK PERFORMED IN CONNECTION WITH THESE CONTRACT DOCUMENTS SHALL COMPLY WITH THE ANOD ANODIZED MECH MECHANICAL (209)481-8981 STRUCTURAL ENGINEER: G4.0 ACCESSIBILITY STANDARDS S3.4 STRUCTURAL ENTRY CANOPY DETAILS <br /> AMERICANS WITH DISABILITIES ACT(ADA),ALL APPLICABLE STATE AND LOCAL CODES,ORDINANCES,AND APPROX APPROXIMATE MEMB MEMBRANE AXIOM STRUCTURAL DESIGN S4.1 STAIR FOUNDATION AND FRAMING PLAN <br /> ZONING REGULATIONS IN EFFECT ATTHE TIME OF CONSTRUCTION.THIS PROJECT SHALL COMPLY WITH TITLE ARCH ARCHITECT MFR MANUFACTURER 01 DOOR REFERENCE NUMBER ARCHITECT: 337 Burney St CIVIL S4.2 STAIR SECTION <br /> 24,2016 CBC,CMC,CPC,CFC,CEC BASED ON THE 2013 CALIFORNIA ENERGY STANDARDS. B.O. BOTTOM OF MIN MINIMUM NJ ASSOCIATES INC Modesto CA 95354 C-1 TITLE SHEET S4.3 STAIR DETAILS <br /> 4. IT SHALL BE UNDERSTOOD THAT THE INTENT OF THESE CONSTRUCTION DOCUMENTS IS TO CONSTRUCTTHE BALC BALCONY MISC MISCELLANEOUS 22769 N BENDER ROAD 209 360 2960 <br /> FACILITY IN ACCORDANCE WITH THE APPLICABLE CODES AND ORDINANCES.SHOULD ANY CONDITION BE BD BOARD MO MASONRY OPENING 01 RATED DOOR REFERENCE NUMBER ACAMPO CA 95220 andrew@axiomsd.com C-2 GENERAL NOTES <br /> UNCOVERED OR DEVELOP DURING THE EXECUTION OF THESE DOCUMENTS,WHICH IS NOT DEFINED HEREIN, BET BETWEEN MTD MOUNTED 209.727.2040 C-3 CITY STANDARD DETAILS MECHANICAL <br /> THE CONTRACTOR SHALL CEASE WORKAND NOTIFYTHE ARCHITECT AT ONCE." BLDG BUILDNG MTL METAL MECHANICAL/PLUMBING: C-4 EXISTING SITE PLAN-DEMO PLAN MO MECHANICAL SCHEDULES,DETAILS,AND NOTES <br /> 5. THE TYPICAL DETAILS SHOWN IN THESE PLANS SHALL APPLY IN ALL SIMILAR CASES UNLESS SPECIFICALLY BLKG BLOCKING N NORTH WINDOW REFERENCE NUMBER CONTACT: GDMD Engineering,Inc. C-5 DIMENSION AND PAVING PLAN MO.1 MECHANICAL SCHEDULES,DETAILS,AND NOTES <br /> NOTED OTHERWISE. WHERE NO DETAIL IS SHOWN,CONSTRUCTION SHALL BE AS INDICATED FOR OTHER BLW BELOW NIC NOT IN CONTRACT JOHN VIERRA,ARCHITECT 212 W Pine St,Ste 4 C-6 GRADING AND DRAINAGE PLAN M1 MECHANICAL FIRST FLOOR PLAN <br /> SIMILAR WORK AND,OR APPLICABLE INDUSTRY PRACTICE. BM BEAM NO NUMBER john@njaarchitecture.com Lodi,CA 95240 C-7 UTILITY PLAN M2 MECHANICAL SECOND FLOOR PLAN <br /> 6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL COORDINATION OF INSTALLATION,INSPECTION,AND BOT BOTTOM NOM NOMINAL S33 STOREFRONT REFERENCE NUMBER Ph 209-367-0899 Fax 209-367-0898 <br /> FINAL APPROVAL OF ALL UTILITIES." BRKT BRACKET NTS NOT TO SCALE E-mail:gdmdengrinc@sbcglobal.net C-8 EROSION CONTROL PLAN T24.1 TITLE 24 DOCUMENTATION <br /> 7. VERIFY ALL DIMENSIONS,EXISTING CONDITIONS,AND METHODS OF CONSTRUCTION PRIOR TO START OF ANY BUR BUILT UP ROOF O.P. OVERFLOW PIPE C-9 LOCKEFORD STREET IMPROVEMENTS T24.2 TITLE 24 DOCUMENTATION <br /> WORK.NOTIFY THE ARCHITECT OF ANY DISCREPANCIES." C.G. CORNER GUARD OA OVERALL KEYNOTE REFERENCE NUMBER ELECTRICAL ENGINEER: C-10 SACRAMENTO STREET IMPROVEMENTS T24.3 TITLE 24 DOCUMENTATION <br /> 8. IT IS NOTTHE INTENT OF THESE CONTRACT DOCUMENTS TO SEPARATE THE WORK INTO SUBTRADE DIVISIONS. CAB CABINET OC ON CENTER HCS ENGINEERING <br /> IT SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO DIVIDE THE WORK AND ORGANIZE ALL CALK CAULKING OD OUTSIDE DIAMETER 4512 FEATHER RIVER DRIVE, ARCHITECTURAL PLUMBING <br /> WORK AS REQUIRED TO COMPLETE THE WORK AS INTENDED BYTHESE DOCUMENTS." CEM CEMENT OFF OFFICE STE F STOCKTON,CA 95219 <br /> 9. SITE DEVELOPMENT AND GRADING SHALL PROVIDE ACCESS TO PRIMARY ENTRANCES AND NORMAL PATHS CER CERAMIC OH OPPOSITE HAND (209)478-8270 A1.0 SITE PLAN PO PLUMBING SCHEDULES,DETAILS,AND NOTES <br /> OF TRAVEL,AND SHALL INCORPORATE PEDESTRIAN RAMPS,CURB RAMPS,ETC.ALL RAMPS SHALL HAVE A CJ CONTROL JOINT OPG OPENING GRID LINE A1.1 ENLARGED PARKING PLAN PO.1 PLUMBING SCHEDULES,DETAILS,AND NOTES <br /> MAXIMUM SLOPE OF 1:12,OR AS NOTED ON THESE CONSTRUCTION DOCUMENTS.ANY PATH OF TRAVEL CLG CEILING OPP OPPOSITE A1.2 ENLARGE BUILDING SITE PLAN P1.1 PLUMBING SS,GAS,AND VENT FIRST FLOOR PLAN <br /> SHALL BE CONSIDERED A RAMP IF IT'S SLOPE IS GREATER THAN 1 FT.RISE IN 20 FT.RUN(50/6)" CLOS CLOSET PART PARTITION AIA SITE DETAILS P1.2 PLUMBING HOTAND COLD WATER FIRST FLOOR <br /> 10. EACH PARKING FACILITY WHERE PARKING IS PROVIDED FOR THE PUBLIC,GUESTS OR EMPLOYEES SHALL CLR CLEAR PERM PERIMETER PROJECT DATA: A1.5 SITE DETAILS PLAN <br /> PROVIDE ACCESSIBLE PARKING AND LOADING STALLS DESIGNATED SPECIFICALLY FOR HANDICAPPED CO CASED OPENING PG PAINT GRADE SECTION REFERENCE: <br /> PERSONS." COL COLUMN PLAM PLASTIC LAMINATE A2.0 FIRST LEVEL DIMENSION PLAN P2.1 PLUMBING SS,GAS,AND VENT FIRST SECOND <br /> 11. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION OF ALL EXISTING UNDERGROUND CONC CONCRETE PLAS PLASTER 1 DETAIL NUMBER A2.1 FIRST LEVEL ANNOTATION PLAN PLAN <br /> UTILITIES PRIOR TO THE COMMENCEMENT OF WORK. HE SHALL BE RESPONSIBLE FOR THE LOCATION CONT CONTINUOUS PLYWD PLYWOOD A7.00 SIM CODE REFERENCE: PROJECT INFORMATION: A2.2 SECOND LEVEL DIMENSION PLAN P2.2 PLUMBING HOT AND COLD WATER SECOND <br /> AND PRESERVATION OF ALL SUCH FACILITIES IN THE AREA OF CONSTRUCTION,AND SHALL NOTIFY UTILITY CPT CARPET PR PAIR SHEET NUMBER SCOPE OF WORK: TWO STORY BOWLING ALLEY W/RESTUARANT, A2.3 SECOND LEVEL ANNOTATION PLAN FLOOR PLAN <br /> COMPANIES 48 HOURS IN ADVANCE OF ANY CONSTRUCTION(UNDERGROUND SERVICE ALERT CT CERAMIC TILE PT PAINT BAR AREA&BANQUET ROOM. A3.0 FIRST LEVEL REFLECTED CEILING PLAN <br /> 1-800-227-2600)" CTR CENTER PTD PAINTED ELECTRICAL <br /> A3.1 SECOND LEVEL REFLECTED CEILING PLAN <br /> 12. EACH PARKING SPACE RESERVED FOR PERSONS WITH PHYSICAL DISABILITIES SHALL BE IDENTIFIED BY A DBL DOUBLE R RISER 1 ELEVATION: EO.1 GENERAL NOTES <br /> REFLECTORIZED SIGN PERMANENTLY POSTED IMMEDIATELY ADJACENTTO AND VISIBLE FROM EACH STALL DET DETAIL RAD RADIUS `� LOCATION: 302 N SACRAMENTO STREET A4.0 ROOF PLAN <br /> DETAIL NUMBER A5.0 EXTERIOR ELEVATIONS E0.2 GENERAL NOTES <br /> OR SPACE,CONSISTING OF A PROFILE VIEW OF A WHEELCHAIR OCCUPANT IN WHITE ON A BLUE DIA DIAMETER RCP REFLECTED CEILINGPLAN 1 A1.00 1 LODI,CA 95240 E0.3 LIGHTING CONTROLS <br /> BACKGROUND.THE SIGN SHALL NOT BE SMALLER THAN 70 SQ.IN.IN AREA AND,WHEN POSTED IN A PATH OF DIM DIMENSION RD ROOF DRAIN A5.1 EXTERIOR ELEVATIONS E1.1 ELECTRICAL SITE PLAN <br /> TRAVEL,SHALL BE A MINIMUM HEIGHT OF 80 INCHES FROM THE BOTTOM OF THE SIGN TO THE PARKING DN DOWN RE REFER APN: 041-166-01 thru 05,04-210-14 A6.0 BUILDING SECTIONS <br /> SPACE FINISH GRADE,LION.IN ADDITION,A SIGN,AS SPECIFIED IN TITLE 24 ACCESSIBILITY STANDARDS,SHALL DR DOOR REF REFRIGERATOR 1 SHEET NUMBER E1.2 PARKING LOT PLANS <br /> A6.1 BUILDING SECTIONS <br /> BE POSTED IN A CONSPICUOUS PLACE,AT EACH ENTRANCE TO OFF-STREET PARKING FACILITIES,OR DS DOWN SPOUT REINF REINFORCED BUILDING ANALYSIS: E2.1 FIRST FLOOR LIGHTING PLAN <br /> IMMEDIATELY ADJACENT TO AND VISIBLE FROM EACH STALL OR SPACE.SAID SIGNS SHALL BE NOT LESS THAN DW DISHWASHER REQD REQUIRED DETAIL REFERENCE: A6.2 WALL SECTIONS <br /> BUILDING AREA: 1 ST FLOOR= 23,423 SF E2.2 SECOND FLOOR LIGHTING PLAN <br /> 17 INCHES X 22 INCHES IN SIZE WITH LETTERING NOT LESS THAN 1 INCH HIGH." DWG DRAWING RESIL RESILIENT 1 ST FLOOR OUTDOOR SEATING= 567 SF A6.3 WALL SECTIONS <br /> SIM <br /> 1 DETAIL NUMBER A64 WALL SECTIONS E3.1 FIRST FLOOR FRONT ELECTRICAL PLAN <br /> 13. PROVIDE A CLEAR AND LEVEL LANDING ON EACH SIDE OF AN EXIT DOOR.THE LANDING SHALL BE 48 INCHES E EAST RM ROOM 2ND FLOOR= 21,547 SF . <br /> E3.2 KITCHEN ELECTRICAL PLAN <br /> IN LENGTH WHERE THE DOOR SWINGS AWAY FROM THE LANDING,AND 60 INCHES IN LENGTH IN THE EA EACH RO ROUGH OPENING A9.00 TOTAL AREA= 45,537 SF A7.0 ENLARGED KITCHEN PLAN E3.3 FIRST FLOOR BOWLING ELECTRICAL PLAN <br /> DIRECTION OF DOOR SWING AS MEASURED AT RIGHT ANGLES TO THE PLANE OF THE DOOR IN THE CLOSED EIFS EXTERIOR INSULATION&FINISH SYSTEM RTU ROOFTOP UNIT(MECH) PROJECT AREA: 45,537 SF A7.1 STAIR PLANS&DETAILS <br /> SHEET NUMBER E3.4 SECOND FLOOR ELECTRICAL PLAN <br /> POSITION." ELEC ELECTRIC S SOUTH NUMBER OF STORIES: 2 STORIES A7.2 SECOND LEVEL ENLARGED FLOOR PLAN/INTERIOR <br /> 14. GENERAL DEMOLITION:WHENEVER EXISTING FACILITIES OR MATERIALS ARE REMOVED,DAMAGED,BROKEN, ELEV ELEVATION SAFB SOUND ATTENUATION FIBER BATT ACTUAL BUILDING HEIGHT: 48'-10" ELEVATIONS E3.5 FIRST FLOOR HVAC ELECTRICAL FLOOR PLAN <br /> OR CUT IN THE INSTALLATION OF WORK COVERED BY THE DRAWINGS AND SPECIFICATIONS,SAID FACILITIES EMER EMERGENCY SC SCUPPER 1ST LEV L ELEVATION HEIGHT MARKER: E3.6 SECOND FLOOR HVAC ELECTRICAL FLOOR PLAN <br /> AND MATERIALS SHALL BE REPLACED ATTHE CONTRACTOR'S EXPENSE. SAID FACILITIES OR MATERIALS ENCL ENCLOSURE SCHED SCHEDULE CBC 303-314 OCCUPANCY GROUP: A-3,A-2 A7.3 INTERIOR ELEVATIONS <br /> 0-0 E3.7 ELECTRICAL ROOF PLAN <br /> SHALL BE EQUALTO OR BETTER THAN THE ORIGINAL FACILITIES OR MATERIALS.THE FINISH PRODUCT SHALL EOS EDGE OF SLAB SEAL SEALANT LEVEL NAME CBC TABLE 601 CONSTRUCTION TYPE: II-B A7.4 INTERIOR ELEVATIONS E4.1 ONE LINE DIAGRAM ARCHITECTS STAMP <br /> BE SUBJECTTO THE APPROVAL OF THE COUNTY AND ITS AGENTS" EQ EQUAL SECT SECTION HEIGHT CBC 508 SEPARATED OR NON-SEPARATED USE: NON-SEPARATED A7.5 INTERIOR ELEVATIONS <br /> 15. NO WORK SHALL COMMENCE ATTHE PROJECT SITE BEFORE A BUILDING PERMIT IS FULLY EXECUTED AND EQUIP EQUIPMENT SF SQUARE FOOT A7.6 INTERIOR ELEVATIONS E4.2 PANEL SCHEDULES <br /> AVAILABLE FOR POSTING ATTHE JOB SITE." ETR EXISTING TO REMAIN SHT SHEET CBC TABLE 506.2 ALLOWABLE AREA: 76,000 SF A8.0 ROOM FINISH SCHEDULE E4.3 PANEL SCHEDULES <br /> 16. CONSTRUCTION LIMITS:CONTRACTOR AND SUB-CONTRACTORS,WORKERS AND OTHER PERSONNEL RELATED EW EACH WAY SIM SIMILAR 8'4' SPOT ELEVATION HEIGHT MARKER CBC 506.2 AREA INCREASE: N/A A8.1 DOOR&WINDOW SCHEDULES E4.4 PANEL SCHEDULES SSD <br /> S1 /� <br /> TO THIS SCOPE OF WORK,SHALL BE CONFINED WITH THE AREAS DESIGNATED AS CONSTRUCTION LIMITS AS EXP.JT. EXPANSION JOINT SPEC SPECIFICATION CBC TABLE 504.3 ALLOWABLE HEIGHT: 75'-0" A8.3 DOOR&WINDOW TYPES E4.5 ELECTRICAL DETAILS � <br /> INDICATED BY THESE DRAWINGS AND RELATED AREAS. AREAS BEYOND THIS SCOPE OF WORK SHALL BE OFF EXST EXISTING SQ SQUIRE HEIGHT INCREASE: N/A C� <br /> LIMITS,AND THEIR USE SHALL BE PROHIBITED WITHOUT PRIOR AUTHORIZATION OF SAN JOAQUIN COUNTY. F.O. FACE OF SS STAINLESS STEEL CBC TABLE 504.4 ALLOWABLE NUMBER OF STORIES: 3 STORIES A9.0 ASSEMBLIES ET24A COMPLIANCE -r JOHN A VIERRA <br /> THE GENERAL CONTRACTOR SHALL VERIFY THESE LIMITS AND BE RESPONSIBLE TO INFORM THE APPROPRIATE FA FIRE ALARM STD STANDARD A9.1 DETAILS ET24B COMPLIANCE C-35199 <br /> PERSONNEL AND ENFORCE THESE LIMITS." FAP FIRE ANNUNCIATOR PANEL STL STEEL CBC 903.2 AUTOMATIC FIRE SPRINKLERS: YES A9.2 DETAILS ET24C COMPLIANCE <br /> 17. PROVIDE CONTINUOUS 16GA.X REQUIRED WIDTH(6""MIN.)FLAT BACKING STRAP AT WALLS WITH WALL FD FLOOR DRAIN STOR STORAGE CBC 907.2 FIRE ALARM: YES10-31-2019 <br /> A9.3 DETAILS N __ <br /> MOUNTED EQUIPMENT,CASEWORK,AND/OR ACCESSORIES-TYPICAL UNLESS OTHERWISE NOTED." FE FIRE EXTINGUISHER STRUCT STRUCTURAL OTHER FIRE PROTECTION SYSTEM: NO METAL BUILDING RENEWAL - <br /> 18. THE CONTRACTOR SHALL CAREFULLY STUDY AND COMPARE THE CONTRACT DOCUMENTS AND THE FEC FIRE EXTINGUISHER CABINET SUSP SUPSPENDED CBC 909 SMOKE CONTROL SYSTEM: NO A9.4 DETAILS 9) DATE Q- <br /> EXISTING FIELD CONDITIONS,AND SHALL AT ONCE REPORTTO THE ARCHITECT ANY ERROR,INCONSISTENCY, FG FINISH GROUP SYM SYMMMETRICAL A9.5 DETAILS SEE DRAWINGS FOR FULL LIST OF SHEETS F 0P C ALF❑ <br /> OR OMISSION HE MAY DISCOVER.THE CONTRACTOR SHALL PERFORM NO PORTION OF THE WORK AT ANY FH FIRE HYDRANT T TREAD CBC TABLE 1004.1.2 OCCUPANT LOAD: FIRST FLOOR= 682 <br /> TIME WITHOUTAPPROVED CONTRACT DOCUMENTS OR WHERE REQUIRED,APPROVED SHOP DRAWINGS, FHC FIRE HOSE CABINET T&G TONGUE&GROOVE SECOND FLOOR= 499 STRUCTURAL <br /> PRODUCT LITERATURE,DATA,SAMPLES OR INSTALLATION INSTRUCTIONS." FIN FINISH TEL TELEPHONE TOTAL= 1,181 <br /> 19. THE CONTRACTOR SHALL OBTAIN AN ENCROACHMENT PERMIT,WHERE APPLICABLE,FOR ANY WORK DONE FLR FLOOR TER TERRAZZO REVISIONS <br /> WITHIN THE RIGHT-OF-WAY OR EASEMENTS FROM THE AUTHORITY HAVING JURISDICTION.THE CONTRACTOR FLUOR FLOURESCENT THK THICK YEAR BUILDING WAS CONSTRUCTED: TBD <br /> SHALL NOTIFYTHE OWNER 48 HOURS IN ADVANCE OF COMMENCEMENT OF THE WORK OR AS REQUIRED BY FRP FIBER-REINFORCED PLASTIC THR THRESHOLD No. Description Date By <br /> SAID PERMITS." FT FOOT OR FEET TO TOP OF HIGH-PILE STORAGE: NO <br /> 20. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CUTTING,FITTING,OR PATCHING THAT MAY BE REQUIRED FUR FURRING TYP TYPICAL <br /> TO COMPLETE THE INTENT OF THESE CONSTRUCTION DOCUMENTS,TO MAKE IT'S SEVERAL PARTS FIT G.S.M. GALVANIZED SHEET METAL UC UNDERCUT <br /> TOGETHER PROPERLY.THE CONTRACTOR SHALL PATCH ARCHITECTURAL FINISHES AS NECESSARYTO GAL GALLON UNPIN UNFINISHED <br /> ACCOMPLISH WORK DEFINED IN STRUCTURAL,MECHANICAL,PLUMBING,ELECTRICAL,AND ARCHITECTURAL GALV GALVANIZED UNO ULNESS NOTED OTHERWISE <br /> DRAWINGS.EXISTING FIELD CONDITIONS SHALL BE VERIFIED BY THE CONTRACTOR AND ACCEPTED AS GB GRAB BAR UON UNLESS OTHERWISE NOTED <br /> CONDITIONSOF THISALCON CONTRACTOR SHALL <br /> GC GENERAL CONTRACTOR UTIL UTILITY APPLICABLE CODES: DEFERRED SUBMITTALS: <br /> 21. THE ELECTRICAL CONTRACTOR SHALL COORDINATE WITH PG&E AND/OR SERVICE PROVIDER FOR ANY NEW GL GLASS VCT VINYL COMPOSITION TILE <br /> SERVICE INSTALLATIONS.THE CONTRACTOR SHALL COORDINATE THE SHUT DOWN OF THE FACILITIES WITH GND GROUND VERT VERTICAL <br /> THE OWNER FOR AS MINIMAL DURATION AS POSSIBLE.INTERCEPTTHE EXISTING SERVICE CONDUIT,EXTEND IT GWB GYPSUM BOARD VIF VERIFY IN FIELD Project No.: 17028 <br /> TO NEW TRANSFORMERS AND PAD(TO BE INSTALLED BY CONTRACTOR)AND EXTEND SECONDARY GYP GYPSUM VTR VENTTERMINATION PIPE TITLE 19 CALIFORNIA CODE OR REGULATIONS,PUBLIC SAFETY,STATE FIRE MARSHAL REGULATIONS 1. FIRE SPRINKER SYSTEM-SHALL BE SUBMITTED UNDER A SEPARATE PERMIT AND COVER TO THE BUILDING <br /> CONDUITS TOTHE NEW SWITCHBOARD.COORDINATE WITH THE OWNER TO VERIFY LOCATION,PROVIDE H.W.H. HOT WATER HEATER VWC VINYL WALL COVERING DEPARTMENT BY A C-16 LICENSED CONTRACTOR. Drawn By: NS <br /> TRAFFIC BARRIER POSTS PER PG&E REQUIREMENTS." HDWD HARDWOOD W WEST TITLE 24 CALIFORNIA CODE OR REGULATIONS: Checked By: JV <br /> 22. CONTRACTOR SHALL FLUSH ALL WATER,SEWER,AND DRAIN LINES PRIOR TO HOOK UP." HDWR HARDWARE W/ WITH PART 1 -2016 BUILDING STANDARDS ADMINISTRATIVE CODE 2. FIRE ALARM SYSTEM-SHALL BE SUBMITTED UNDER A SEPARATE PERMIT AND COVER TO THE BUILDING <br /> 23. DIMENSIONS SHALL BE MEASURED TO FACE OF FRAMING,U.O.N.DO NOT SCALE DRAWINGS." HM HOLLOW METAL W/0 WITHOUT PART 2-2016 CALIFORNIA BUILDING CODE,VOL.1 &2(CBC)(2012 IBC,AS AMENDED BY CA) DEPARTMENT BY A C-10 LICENSED FIRE ALARM CONTRACTOR. <br /> 24. PROVIDE 2%SLOPE AWAY FROM THE BUILDING FOR 10'-0""AT FRONT AND SIDES." HORIZ HORIZONTAL WC WATERCLOSET PART 3-2016 CALIFORNIA ELECTRICAL CODE(CEC)(2016 NEC,AS AMENDED BY CA) <br /> 25. NO DRAINAGE ACROSS OR ONTO ADJACENT PROPERTY.PROVIDE 2%SLOPE AWAY FROM THE BUILDING FOR HR HOUR WIN WINDOW PART -2016 CALIFORNIA MECHANICAL CODE(CMC)(2016 IAPMO UMC,AS AMENDED BY CA) 3. KITCHEN HOOD FIRE SUPPRESSION SYSTEM. <br /> 10'4""AT FRONT AND SIDES." HT HEIGHT WP WATERPROOF PART 5-2016 CALIFORNIA PLUMBING CODE(CPC)(2016 IAPMO UPC,AS AMENDED BY CA) <br /> 26. DO NOT SCALE THE DRAWINGS." ID INNER DIAMETER WS WETSTACK PARTE-2016 CALIFORNIA ENERGY CODE <br /> INCAN INCANDESCENT WSCT WAINSCOT PART 9-2016 CALIFORNIA FIRE CODE(CFC)(2012 IFC,AS AMENDED BY CA) <br /> INSUL INSULATION WT WEIGHT PART 10-2016 CALIFORNIA EXISTING BUILDING CODE PERMIT SET <br /> INT INTERIOR PART 11 -2016 CALIFORNIA GREEN BUILDING STANDARDS CODE 8.17,18 <br /> PART 12-2016 CALIFORNIA REFERENCED STANDARDS(PARTIAL LIST-SEE CBC CH.35 <br /> AND CFC CH.45) <br /> 2016 NFPA 13,INSTALLATION OF SPRINKLER SYSTEMS(CA AMENDED) <br /> 2016 NFPA 14,INSTALLATION OF STANDPIPE AND HOSE SYSTEMS COVER SHEET <br /> 2016 NFPA 17,DRY CHEMICAL EXTINGUISHING SYSTEMS <br /> 2016 NFPA 17A,WET CHEMICAL EXTINGUISHING SYSTEMS <br /> 2016 NFPA 20,INSTALLATION OF STATIONARY PUMPS FOR FIRE PROTECTION <br /> 2016 NFPA 22,WATER TANKS FOR PRIVATE FIRE PROTECTION" <br /> 2016 NFPA 24,INSTALLATION OF PRIVATE FIRE SERVICE MAINS" <br /> 2016 NFPA 72,NATIONAL FIRE ALARM CODE(CA AMENDED);SEE UL STD.1971 FOR"VISUAL DEVICES" <br /> GOeO0 <br /> 0 <br /> N <br /> r <br /> W <br />