SLEEVE,TYP WHERE PIPES INTERSECT REINF @ <br /> SEE NOTES <br /> FTG WALL TOP OF FTG DEPTH D, STEP FTG TO LAP SPLICE <br /> iv z PASS PIPES ABOVE FTG WIRE TOGETHER, TYP #4 HAIRPIN BAR TO <br /> 01 <br /> PIPE,TYP LENGTH TYP MATCH SPACING OF TYP <br /> EA HORIZ BAR TYP 12d <br /> BO SLAB <br /> 1Y" MIN CLR TO ALL STANDARD HOOK- BENDS AND HOOKS <br /> z FTG OR WALL REINF <br /> TO FTG z �, z TYP 180° HOOK 90° HOOK z D <br /> REBAR SIZE D z O <br /> o � � • O END W L W Q w <br /> 4„ TO FTG #3 2Y4" 3" 4" 6" o o W <br /> ADD'L VERT BAR TO MATCH VER #4 3" 4" 4Y" 8" <br /> III III III Mlo W <br /> IN D/2 MIN o REINF,TYP WHERE SHOWN <br /> #5 3Y4' 5" 5" 10" d TIE HOOKS STIRRUPS <br /> 6d FOR <br /> ARCHITECT <br /> N MIN XBENT BAR TO MATCH SIZE &SPACING <br /> CORNER INTERSECTION INTERSECTION OF EA HORIZ BAR, TYP WHERE SHOWN NJ ASSOCIATES <br /> #6 4Y" 6" 6" 12" AND SMALLER <br /> 22769 N BENDER ROAD <br /> STEP FOOTING WHERE OCCURS, III_ SINGLE STEP FOOTING SHOWN #7 5X" 7" 7" 14" 90° HOOK ACAMPO CA 95220 <br /> SEE TYPICAL DETAILS MULTIPLE STEPS SIMILAR <br /> ABOVE FOOTING #8 6" 8" 8" 16„ www.njaarchitecture.com.2040 <br /> LAP SPLICE SINGLE LAYER BARS 2'-0" www.njaarchitecture.com <br /> LENGTH TYP TYP <br /> #9 9%" 11%4" 104" 19Y4" <br /> O z D <br /> HATCHING INDICATES AREAz O J CLIENT <br /> WITHIN FTG WHERE PIPES ARE #10 10%4 13Y4" 11Y" 22" Q z <br /> Lu <br /> ALLOWED TO PASS THROUGH #11 12" 14Y4" 12Y4" 24" Lu :E JOE HADDAD <br /> 1Y" CLR D MIN W z P.O.BOX 484 <br /> 01 U- <br /> TO ALL FTG u J WALNUTGROVECA 95690 <br /> REINF,TYP 4" SLEEVE, TYP Q z <br /> PIPE TYP SEE NOTES d 415.517.9686 <br /> MIN END STIRRUP AND TIE HOOK- BENDS AND HOOKS <br /> TO FTG <br /> 180° HOOK 90° HOOK 135° HOOK <br /> O NOTES: REBAR SIZE D 180° HOOK PROJECT <br /> -Z16) 1. SEE CONCRETE NOTES W L W W LODI BOWLING <br /> — AND TYPICAL DETAILS FOR #3 1Y2" 3" 4" 3Y8" 5Y8" <br /> O REBAR CLEARANCES. 302 N SACRAMENTO STREET <br /> CORNER INTERSECTION INTERSECTION <br /> 1 L � 2. VERTICAL REBAR NOT #4 2" 4" 4Y" 4Y" 5Y" LODI CALIFORNIA 95240 <br /> ", "'I II III II"III— 2 SHOWN, SEE DETAILS. z <br /> #5 2Y" 5" 5" 5W 9/" D <br /> A DOUBLE LAYER BARS z O <br /> -III I' I I I,�,I 111 III I I - <br /> STEP FOOTING WHERE OCCURS, - I= #6 4Y" 6" 6" 12" 7Y" Q w <br /> SCALE SEE TYPICAL DETAILS WHERE PIPE(S) INTERSECT u J SCALE #k7 5Y4" 3 " <br /> 1 O REINF @ BOT OF FTG STEP 4 HOOKS AND CORNER BARS 7" 7" 14" 8/4 <br /> - SINGLE STEP FOOTING SHOWN FTG TO MAINTAIN PIPES p W 1" = T-0" <br /> � #8 6" 8" 8" 16" 10" <�&MULTIPLE STEPS SIMILAR IN AREA SHOWN ALL GRADES OF STEEL d , ` , ` I O <br /> THROUGH FOOTING D = MINIMUM FINISHED INSIDE BEND DIA S T R U C T U R A L <br /> d = NOMINAL REBAR DIAMETER 135° HOOK D E S I G N I N C <br /> FTG WIDTH 2xFTG WIDTH TOL = TOLERANCE (PER ACI 117) 337 BURNEV STREET ANDREW (209) 604-2898 <br /> MODESTO, CA 95354MICHAEL (209)484-8640 <br /> W W W A X 1 O M 5 D C O M <br /> 3'-0" MIN <br /> U = LEAN CONCRETE MIX PLACES PRIOR IF SPACING IS LESS THAN 2xD, REMOVE D D <br /> a TO POUR, OR CONCRETE POURED W/ SOIL THIS AREA AND FILL W/SAME 1'-6" MIN <br /> O '-'-' Ys" WIDE SAW CUT FACE OF FTG GRADE LINE 6 <br /> v o FOOTING (MATCH FOOTING WIDTH) MATERIAL AS @ ADJACENT PIPES <br /> m FILLED W/GROUT OR <br /> 1 <br /> ZIP STRIP OF DEPTH — � D �\V <br /> SHOWN TO FTG _- <br /> 11j1 -I -III-I -I k <br /> o 1111111 11111111�11111�11111�11 I IS I 11::::::111 II I II �I I I- OFFSET BEND <br /> 111111111111��1111�11111illlll� II,;,II <br /> CID III„�I 11111111�X111, I I�- <br /> N LLI SLEEVE,TYP ° N z NO TRENCHES CONCRETE REBAR LAP SPLICE LENGTHS <br /> A a ° SEE NOTES a <br /> a z_ 4 ADJACENT TO FACE BAR SIZE <br /> #3x36” LONG PLAIN DOWELS � g 1\ OF FTG BELOW THIS f'C BAR LOCATION <br /> @ 24" OC GREASE Yz OF DOWEL ° PIPE TYP° a°° ° ° z �\ LINE <br /> X \ / #3 #4 #5 #6 #7 #8 #9 #10 #11 <br /> N °Q ° ° a - — <br /> N 2 EXCAVATE TRENCH <br /> z z a /\ a ° ° • ° O°° \ & BACKFILL PER 3,000 TOP 22" 29" 36.. 43" 62" 71" 80" 91" " <br /> 101 <br /> BOT OF CONT SPECS <br /> O° ° / \ 2 `° ° OF SPREAD FTG I BOTTOM 17" 22" 28" 33" 48" 55" 62" 70" 78" <br /> ° / \ II ° °° - z PIPE <br /> i'T <br /> N o z / \ ° MIN d 1° \ tai TOP 19" 25" 31" 37" 54" 62" 70" 79" 87" <br /> a °® / 1 — --111- \ 2 \ 4,000 BOTTOM 15" 19" 24" 29" 42" 48" 54" 61" 67" <br /> - - - - - <br /> B CONSTRUCTION JOINT 611 17 01 D/4 611 \ \ 1 NOTES: <br /> MIN MIN MIN FOR DEEPER TRENCHES 1. REINFORCING BEING LAP SPLICED MUST MEET ONE OF THE FOLLOWING CONDITIONS: <br /> SEE TYP DETAIL TO STEP <br /> TOOLED RADIUS DOWEL, MATCH 1'-6" MIN 01 SPACE 4xD MAX CONT FTG OR DROP PAD A. CASE 1:THE CLEAR SPACING OF THE BARS BEING SPLICED IS NOT LESS THAN ONE BAR DIAMETER, CLEAR COVER <br /> O J <br /> SLAB REINF SIZE & TYP 2xD MIN TYP FTG TO MAINTAIN LIMITS IS NOT LESS THAN ONE BAR DIAMETER,AND STIRRUPS OR TIES THROUGHOUT THE SPLICE LENGTH. <br /> u SPACING MAKE SAME DEPTH WHEN SHOWN i'T� B. CASE 2:THE CLEAR SPACING OF THE BARS BEING SPLICED IS NOT LESS THAN TWO BAR DIAMETERS AND THE <br /> tai CLEAR COVER IS NOT LESS THAN ONE BAR DIAMETER. <br /> SPACING IS LESS 2xD, C. FOR ALL OTHER CASES, MULTIPLY THE SPLICES SHOWN BY 1.5. <br /> = = = _ NO STEPS PERMITTED NOTES: <br /> -III -1 2. THE ABOVE VALUES ARE FOR: UNCOATED REINFORCEMENT, GRADE 60 REBAR, CLASS B, NORMAL WEIGHT CONCRETE <br /> CD Z #4 CONT PIPE 1. TRENCHING LIMITATIONS ARE SAME FOR BOTH FACES OF FOOTING <br /> � EXCAVATE & BACKFILL TRENCH PER SPECS 3. TOP BARS ARE HORIZONTAL REINFORCEMENT WITH MORE THAN 12" OF NEW CONCRETE PLACED BELOW THE BAR. <br /> 2. MAINTAIN LIMITS SHOWN FOR WIDER OR SHALLOWER FOOTINGS BEYOND, BOTTOM BARS ARE ALL OTHER HORIZONTAL OR VERTICAL REINFORCEMENT. <br /> I=111=111=111=1 1- WHERE OCCURS <br /> BELOW FOOTING <br /> M J o'I 'I <br /> w <br /> rj PIPE ADJACENT TO FOOTING SCALE 2 REBAR BENDS, HOOKS AND SPLICES SCALE <br /> 1, = T-0" 1„ = 1'-0" <br /> SLAB EDGE SEE NOTE 4 a 90°WHEN CROSSING THROUGH <br /> 1" CLR V OR ABOVE FTG 60° MIN WHEN <br /> CROSSING BELOW FTG <br /> = 18" MAX <br /> Q < a LARGER ADJACENT d LARGER <br /> � ¢ z � ADJACENT <br /> #4 CONT 00 w O 8" MAX INCLUDING TOTAL DEPTH NOTES: d TYP <br /> CONIC SLAB SEE PLAN SLAB z OF INTERSECTION PIPES d Acl d d <br /> u REINF "^ 1. PIPE AS NOTED SHALL REFER 2 Q a TYP REVISIONS <br /> TO: PIPES, DUCTS, CONDUITS, <br /> } J w No. Description Date By <br /> I III= it WRAP 1" MIN ALL AROUND ETC. ELECTRICAL CONDUITS 1" N <br /> — 1 PROVIDE JOINTS AS DIA OR LESS NEED NOT BE <br /> SLEEVED. <br /> TYP <br /> TYP PIPE CROSSING BUNDLE PIPE AS TIGHTLY AS 1 SHOWN FOR COVERED <br /> �1 CONCRETE CONTACT 2. PIPES SHALL BE INSTALLED <br /> FOOTING POSSIBLE <br /> 6" ARCH FOR EXPOSED SUCH THAT CUTTING, BENDING O O O <br /> CONDITIONS OR DISPLACEMENT OF <br /> MIN III III III III III III III III III REINFORCEMENT FROM ITS <br /> III—III— 1'-6" III-1111 <br /> III 1 — PROPER LOCATION WILL NOT <br /> D SLAB DEPRESSION <br /> PLAN BUNDLED PIPE GROUPS BE REQUIRED. Project No.: 17028 <br /> SLEEVE Y TOTAL DEPTH 3. PIPES EMBEDED IN SLABS & #5 T&B ADD'L MIN TYP 1 <br /> #306" LONG PLAIN DOWELS NOTES 8" AS REQ'D OF THICKENED WALLS SHALL BE 2" MAX DIA& REINF TYP <br /> Y OF DOWEL MIN17 SLAB OR 3" MIN <br /> @ 24" OC GREASE Drawn By: AG <br /> MIN SHEDULE 40 1'-0" 1'-0" 1'-0" Checked By: MS <br /> O 1. "D" = FOOTING DEPTH, "W" = FOOTING WIDTH, " 4. FLEXIBLE INSULATION ASS" = FOOTING STEP MAX MIN MAX <br /> IN SLAB BELOW REINFORCEMENT NOTED SHALL REFER TO LOW <br /> Lu 2. PIPE AS NOTED SHALL REFER TO: PIPES, DUCTS, CONDUITS, ETC. ELECTRICAL CONDUITS 1"0 OR LESS NEED NOT BE DENSITY POLYEYLENE FOAM <br /> SLEEVED/WRAPPED WITH A DENSITY OF 1.5-3 PCF <br /> 3. THIS DETAIL SHALL APPLY IN ALL CASES WHERE A PIPE MUST CROSS A FOOTING. COORDINATE ELEVATIONS AND (PER ASTM D1622) LAYERED TO <br /> LOCATIONS OF ALL PIPES & FOOTINGS ACCORDINGLY. CONTACT STRUCTURAL ENGINEER OF RECORD FOR 2 SLAB/WALL - SPACING d to 3d <br /> III—III—III- CONDITIONS NOT COVERED. SLEEVE AS REQ'D MEET THICKNESS PERMIT SET <br /> Lu O' =1 = 4. ALL PIPES SHALL BE SLEEVED OR WRAPPED AS SHOWN. SLEEVE INSIDE DIAMETERS SHALL BE MIN 2" LARGER THAN REQUIREMENTS. <br /> PIPE OUTSIDE DIAMETER. CENTER PIPES WITHIN SLEEVE. PIPES IN PLACE PRIOR TO PLACING CONCRETE MAY BE" d 3x LARGER 8.17.18 <br /> EXPANSION JOINT WRAPPED WITH 1THICK FLEXIBLE INSULATION INSTEAD OF SLEEVE REINF <br /> E ADJACENT d MIN <br /> 5. SLEEVE/WRAP SHALL EXTEND THE FULL WIDTH OF FOOTING. SEAL ENDS OF SLEEVE/WRAP AS REQUIRED TO PREVENT <br /> WATER PENETRATION D/3,Y4" MIN COVER <br /> OR 1%" MIN COVER IF <br /> (E) CONIC SLAB 6. MULTIPLE PIPES SHALL COMPLY WITH THE HORIZONTAL AND VERTICAL SPACING SHOWN OR BE GROUPED INTO ONE <br /> #3x24" LONG DOWELS @ 18" OC EXPOSED TO EARTH <br /> W/3Y" EMBED INSTALL W/EPDXY LARGE BUNDLE WITHIN THE LIMITATIONS SHOWN. MULTIPLE BUNDLED PIPE GROUPS SHALL BE SPACED 4xD OR WEATHER CONCRETE TYPICAL DETAILS <br /> C1 MINIMUM ON CENTER <br /> 7. PIPES AND SLEEVE/WRAP SHALL BE ADEQUATELY SUPPORTED AND SECURED AGAINST DISPLACEMENT BEFORE AND > > <br /> DURING CONCRETE PLACEMENT <br /> -- 8. COORDINATE PIPE LOCATIONS SO THAT FOOTING REINFORCING IS NOT DISPLACED. MOVE PIPES TO MAINTAIN 1Y" Q <br /> FOR SLAB INFORMATION CLEAR FROM ALL REINFORCING TO SLEEVE/WRAP 1 1 117 —III_I � O % = z _J >- "D" = SLAB OR WALL THICKNESS <br /> = - � " a = SLEEVE OUTSIDE DIAMETER <br /> III-III- -IIIII _ U w <br /> (THICKNESS, REINFORCEMENT, 9. PIPES NEXT TO BUT NOT CROSSING FOOTINGS SHALL COMPLY WITH TYPICAL DETAIL FOR PIPE ADJACENT TO � I I z a � U w <br /> ETC) SEE PLAN FOOTINGS 0- 0 <br /> EXISTING SLAB 10. FLEXIBLE INSULATION AS NOTED SHALL REFER TO LOW DENSITY POLYETHYLENE FOAM WITH A DENSITY OF 1.5-3 PCF —I N m <br /> F (PER ASTM D1622) LAYERED TO MEET THICKNESS REQUIREMENTS THROUGH SLAB BELOW SLAB SLAB/WALL- SPACING 3d &GREATER <br /> SCALE SCALE SCALE <br /> 12 CONCRETE SLAB & CONCRETE PAD DETAILS 9 PIPE CROSSING FOOTING DETAILS 6 PIPE THROUGH WALL OR SLAB S2 * 1 <br /> 1" = T-0" 1" - 1'-0" T. = 1'-0" <br />