Laserfiche WebLink
ARCH ITECTURE <br /> DAL-1 <br /> 3 60x24 <br /> 275 CFM 275 CFH 200 CFM 200 CFM 200 CFM <br /> CS-4 CS-4 CS-4 CS-4 CS-4 <br /> 12x12 12x12 2 10x10 10x10 10x10 <br /> 91� 6'0 ARCHITECT <br /> It" <br /> 1 12"0 T8110 <br /> 4"0 14'0 <br /> 9'� 12'� FSD IEF-5 8"� 8"� WS-1 NJ ASSOCIATES <br /> 275 CFM 22769 N BENDER ROAD <br /> 12'0 9.0 12x6 ACAMPO CA 95220 <br /> (7-0209.727.2040 <br /> cc) q[I] <br /> " ® ® www.njaarchitecture.com <br /> IEF- IEF 4 150 CF <br /> - c8-4 16'0 CLIENT <br /> 8 12x12 <br /> JOE HADDAD <br /> FAU-15 250 CFM 171 WS 1CFMIYI P.O. BOX 691863 <br /> o a CE-1 910 12x6 STOCKTON CA 95629 <br /> 2000 CFM 10x10 <br /> Ds-1 200o CFM 2 o c 209 481 8981 <br /> 24x22 DR-1 <br /> 24x22 0 0 710 ~ <br /> 150 CFM <br /> CS-4 PROJECT <br /> L J+ v----------A WIF 110_x_10 ® 2000 CFM <br /> = DS-1 LODI BOWLING <br /> 24x22 12000 CFM 302 N SACRAMENTO STREET <br /> FAU-20 DR-1 LODI CA 95240 <br /> 24x22 <br /> 2000 CFM <br /> DS-1 <br /> WIF-1 24x22 FAU-14 <br /> 2000 CFM <br /> DR-1 <br /> 24x22 <br /> � ° e <br /> 2000 CF 4 <br /> FAU-19 DR-1 <br /> 24x22 <br /> IWEF-1 2000 CFM <br /> 24x22 <br /> 2000 CFM 2000 CF <br /> WIF-1 DS-1 DR-1 <br /> 24x22 24x22 <br /> FE <br /> ED <br /> 2000 CFM I—I <br /> DS-1 <br /> 24x22 FAU-13 TO <br /> B W <br /> 2000 CFM <br /> DR-1 <br /> 24x22 <br /> 2000 CFM <br /> FAU-18 DR-1 <br /> 24x22 <br /> WIF-1 � 2000 CFM <br /> DS-1 <br /> 24x22 <br /> H <br /> ® WEF-1 <br /> N <br /> 2000 CFM <br /> DR-1 <br /> 2000 CFM 24x22 <br /> DS-1 <br /> 24x22 <br /> I Lt FAU-12 <br /> PROFESSIONAL STAMP <br /> CD NAL F <br /> 5 <br /> G. <br /> e F. 0 � <br /> a of �G qL� 2 <br /> wIF-1 <br /> 41,1 <br /> NOV M29759" <br /> (J1 REN. 6-30=2O " Q <br /> Q ANSG\�(3 <br /> OF C IS' <br /> REVISIONS <br /> No. Description Date By <br /> 1 MECHANICAL SECOND FLOOR PLAN <br /> SCALE:1/8" = 1' <br /> Project 17028 <br /> DRYER VENT SIZING UPQWn NR <br /> BASIS OF DESIGN -40'OF 4" STRAIGHT PIPE CONVEYTING 60 CFM � ecked GD <br /> WITH A MAXIMUM PRESSURE DROP OF 0.15' WC INCLUDING WALL By: <br /> MECHANICAL SECOND FLOOR PLAN NOTES CAP <br /> INSTALLED EQUIVALE MAX LENGTH <br /> 4"0 FLUE FROM WH-1,2 THRU ROOF PER DETAIL 5/MO, ELBOWS NTLENGTH OF DRIER <br /> PIPE <br /> 2❑ 4"0 DRYER VENT THRU WALL PER DETAIL 2/M0,1, SEE DRYER VENT PERMIT SET <br /> SIZING TABLE THIS SHEET, <br /> 4" DIAMETER PIPE 0 40 40 <br /> 8/17/18 <br /> REFRIGERANT LINES SIZED PER MANUFACTURE'S REC❑MMENDATI❑NS AND 1 6 34 <br /> 3/4"CONDUIT FROM BELOW TO CORRESPONDING FAU-, SEE M1 FOR 2 12 28 <br /> CONTINUATION, 3 18 22 JOB # 2018-061 <br /> INSTALL WEF-1 IN HIGH SECTI❑N OF ROOF. 4 24 6 <br /> 5 30 1SHEET TITLE <br /> GDMD ENGINEERING, INC MECHANICAL SECOND <br /> 5" DIAMETER PIPE 0 100 100 Mechanical and Safety Engineers FLOOR PLAN <br /> 1 6 94 212 W Pine St, Ste 4 <br /> 2 12 88 Lodi, Ca 95242 <br /> (NOT RECOMMENDED) 3 18 82 Ph 209-367-0899 <br /> (NOT RECOMMENDED) 1 4 1 24 1 76 Fax 209-367-0898 <br /> (NOT RECOMMENDED) 5 30 70 <br /> E-mail:gdmdengrinc@sbcglobal.net <br />