My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2023
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
S
>
SNEDEKER
>
809C
>
2800 - Aboveground Petroleum Storage Program
>
PR0528437
>
COMPLIANCE INFO_2023
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/7/2023 4:47:04 PM
Creation date
4/3/2023 8:30:55 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
2023
RECORD_ID
PR0528437
PE
2833
FACILITY_ID
FA0018706
FACILITY_NAME
CANARY RENEWABLES CORP
STREET_NUMBER
809C
STREET_NAME
SNEDEKER
STREET_TYPE
AVE
City
STOCKTON
Zip
95203
APN
16203007
CURRENT_STATUS
01
SITE_LOCATION
809C SNEDEKER AVE
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
490
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Environmental Health Department <br />AMENDED <br />3/30/2023 <br />Aboveground Petroleum Storage Act Inspection Report <br />Date: <br />December 08, 2022 <br /> Facility Address: <br /> 809C SNEDEKER AVE, STOCKTON <br /> Facility Name: <br /> CANARY RENEWABLES CORP <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />RemarksItem # <br /> 610 CFR 112.7(a)(3vi), 112.7(a4) Plan failed to adequately detail information and procedures for reporting a discharge. <br />OBSERVATION: The Spill Prevention, Control, and Countermeasure (SPCC) Plan does not adequately discuss <br />procedures for reporting a discharge. <br />The following was missing from the contact list in SPCC Plan Section 2.2.3: <br />- Phone number for National Response Center (NRC) - (800) 424-8802 <br />The following was missing from SPCC Plan Section 2.2.4 Spill Notification minimum information to be provided: <br />- Date of incident <br />- Evacuations if occurred <br />- Names of individuals/organizations that have been contacted <br />REGULATION GUIDANCE: The SPCC plan shall include: (vi) Contact list and phone numbers for the facility <br />response coordinator, National Response Center, cleanup contractors with whom you have an agreement for <br />response, and all appropriate Federal, State, and local agencies who must be contacted in case of a discharge as <br />described in § 112.1(b). <br />(4) Unless you have submitted a response plan under § 112.20, provide information and procedures in your Plan to <br />enable a person reporting a discharge as described in § 112.1(b) to relate information on the exact address or <br />location and phone number of the facility; the date and time of the discharge, the type of material discharged; <br />estimates of the total quantity discharged; estimates of the quantity discharged as described in § 112.1(b); the <br />source of the discharge; a description of all affected media; the cause of the discharge; any damages or injuries <br />caused by the discharge; actions being used to stop, remove, and mitigate the effects of the discharge; whether an <br />evacuation may be needed; and, the names of individuals and/or organizations who have also been contacted. <br /> <br />CORRECTIVE ACTION: Immediately amend the SPCC Plan to include NRC phone number, date of incident, <br />whether any evacuations occurred, names of individuals/organizations that have been contacted in the procedures <br />for reporting a discharge. Submit proof of correction to the EHD. <br />This is a Class II violation. <br />FA0018706 PR0528437 SC001 12/08/2022 <br />EHD 28-01 Rev. 12/06/2021 Aboveground Petroleum Storage Act OIRPage 10 of 18 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD
The URL can be used to link to this page
Your browser does not support the video tag.