My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2023
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
3425
>
2300 - Underground Storage Tank Program
>
PR0231416
>
COMPLIANCE INFO_2023
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/19/2024 4:25:57 PM
Creation date
4/3/2023 9:37:31 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2023
RECORD_ID
PR0231416
PE
2361
FACILITY_ID
FA0003627
FACILITY_NAME
ARCO 02093
STREET_NUMBER
3425
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95376
APN
21418020
CURRENT_STATUS
01
SITE_LOCATION
3425 TRACY BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\lsauers1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
463
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
S A N J Q Q Q U IN Environmental Health Department <br /> COUNTY <br /> Greorness grows here. <br /> Underground Storage Tank Program Service Request Inspection Report <br /> Name of Facility: ARCO 02093 Date: 05/01/2023 <br /> Address: 3425 TRACY BLVD , TRACY 95376 <br /> Requestor: A&S ENGINEERING/ROBERT VELASCO,A&S ENGINEERING Telephone: (661)250-9300 <br /> Program Element: 2308-UST RETROFIT Request#: SR0086421 <br /> Inspection Type: 298-UST SERVICE REQUEST- FIELD ACTIVITY <br /> Onsite Service Technician: Rogelio Perez ICC Service Tech/Installer Exp. Date: 03/19/2024 <br /> Manufacturer training: NOV, 03/17/24 <br /> OVERALL INSPECTION NOTES AND COMMENTS <br /> NOTES <br /> On site for the following: <br /> -Witnessed secondary containment testing of 87 and 91 product piping. Both passed. <br /> -Witnessed soap testing of 87 and 91 product piping. Both passed. <br /> -Verified piping communication in the secondary containment of 87 and 91 piping. <br /> -Verified appropriate piping setbacks, crossovers, and burial depths of 87 and 91 piping. <br /> -Verified minimum 1/8"per foot slope of 87 and 91 piping. <br /> -Verified use of appropriate backfill. <br /> Piping was only exposed at the UDCs and the drive pad area. Piping at the tanks was not exposed. Verified connection of <br /> new piping to previously existing piping just south of the UDCs. <br /> **Six month secondary containment retesting of the UDCs, 87 piping, and 91 piping is due in October 2023. <br /> *This facility is NOT approved to operate the 87 or 91 UST systems.* <br /> Additional inspections are still needed. Refer to the approval letter dated 3/29/23 for a list of required inspections. <br /> The person in charge is responsible for ensuring that the above mentioned facility is in compliance with all applicable sections of the California Health and <br /> Safety Code.If a reinspection is required,fees will be assessed at the current hourly rate. <br /> Received by: Name and Title: Emailed to owner and contractor, <br /> EH Specialist: STACY RIVERA Phone: (209)616-3043 <br /> FA0003627 SR0086421 SC298 05/01/2023 <br /> EHD 23-01 Rev.07/05/2022 Page 1 of 1 Underground Storage Tank Program Service Request Inspection Report <br />
The URL can be used to link to this page
Your browser does not support the video tag.