My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2023
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
4733
>
2300 - Underground Storage Tank Program
>
PR0232510
>
COMPLIANCE INFO_2023
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:51:22 PM
Creation date
4/3/2023 10:42:21 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2023
RECORD_ID
PR0232510
PE
2361
FACILITY_ID
FA0003924
FACILITY_NAME
HUNT & SONS INC - STOCKTON
STREET_NUMBER
4733
Direction
S
STREET_NAME
STATE ROUTE 99
City
STOCKTON
Zip
95206
APN
17930008
CURRENT_STATUS
01
SITE_LOCATION
4733 S HWY 99
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\lsauers1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SANJOAQUIN <br />COUNTY— <br />Environmental Health Department <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />Facility Address: <br />Date: <br />HUNT & SONS INC - ARCH ROAD CARDLOCK <br />4733 S HWY 99, STOCKTON <br />June 22, 2023 <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />214 <br />CCR 2712 Failure to comply with UST operating permit conditions. <br />OBSERVATION: A cold start was performed on Veeder Root TLS 350 (monitoring panel) on May 4, 2023 and EHD <br />was not notified. <br />REGULATION GUIDANCE: Emergency repairs relating to UST system monitoring and release detection may be <br />performed by a properly licensed, trained, and certified contractor pursuant to the EHD's policy and a permit <br />obtained within one business day from the EHD. All other repairs must have a permit submitted to and approved by <br />the EHD prior to beginning work. <br />CORRECTIVE ACTION: Immediately Contact EHD for the UST component repaired. Failure to contact EHD <br />penalty applies. <br />This is a minor violation. <br />304 <br />CCR 2631(a); HSC 25290.1(c) Failure to construct, operate, and maintain primary containment as product -tight. <br />OBSERVATION: Oily stains were observed in the under dispenser containment sumps (UDCs 5, 8, 9 and 10) <br />indicating a leak in the primary containment. <br />REGULATION GUIDANCE: All primary containment for the UST system must be product tight. <br />CORRECTIVE ACTION: Immediately have a properly licensed, trained, and certified contractor repair or replace the <br />failed component(s), under permit and inspection of the EHD if necessary. <br />This is a Class II violation. <br />319 <br />CCR 2635, 2637.2, 2665, 2712 Failure to comply with overfill prevention equipment requirements. <br />OBSERVATION: Overfill prevention testing was last performed on 5/23/2019 (supposed to have been conducted <br />by 10/2018) the next testing was due on 10/2021 and was completed on 7/21/2022, nine months past due. <br />REGULATION GUIDANCE: Overfill prevention equipment inspections were required to be conducted by October <br />13, 2018, and every 36 months thereafter, and within 30 days of completion of a repair. <br />CORRECTIVE ACTION: Take all necessary precautions to ensure testing is performed in a timely manner. <br />This is a repeat violation, Class II. <br />Overall Inspection Comments: <br />Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br />documenting the corrective actions that have been or will be taken for each violation, and any supporting <br />paperwork, by 7/22/2023 . <br />To minimize person to person contact EHD is choosing to write the name of person receiving the report instead <br />of having them sign. Starting September 1, 2018, all in -office CERS help will be provided at EHD hourly rate <br />($156). To schedule an appointment, please call (209) 468-3420. <br />FA0003924 PR0232510 SCO01 06/22/2023 <br />EHD 23-01 Rev. 12/06/2021 Page 6 of 7 Underground Storage Tank Program OIR <br />1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />
The URL can be used to link to this page
Your browser does not support the video tag.