My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
CORRESPONDENCE_1994-1999
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
AUSTIN
>
9999
>
4400 - Solid Waste Program
>
PR0440005
>
CORRESPONDENCE_1994-1999
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/18/2023 2:28:24 PM
Creation date
4/7/2023 2:11:44 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
CORRESPONDENCE
FileName_PostFix
1994-1999
RECORD_ID
PR0440005
PE
4433
FACILITY_ID
FA0004516
FACILITY_NAME
FORWARD DISPOSAL SITE
STREET_NUMBER
9999
STREET_NAME
AUSTIN
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
20106001-3, 5
CURRENT_STATUS
01
SITE_LOCATION
9999 AUSTIN RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\cfield
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
680
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
L' WASTE eAVL' YPERMIT Facility/Permit Number: <br /> 39-AA-0015 <br /> 17. LEA Conditions: <br /> A.The combined Forward Landfill and the Forward Resource Recovery Facility permitted tons per operating day shall not exceed 6,680 tons(peak). <br /> B.Forward Landfill's contaminated soils acceptance program shall comply with the terms and conditions given in the LEA's letters to Forward dated October 31, 1990; <br /> June 5, 1992;and January 7, 1994. <br /> C.This facility shall comply with all terms and conditions of this permit. <br /> D.This facility shall comply with all applicable State Minimum Standards for solid waste handling and disposal. <br /> E.This facility shall comply with all Federal,State,and Local requirements and enactments,including all mitigation measures given in any certified environmental <br /> document filed pursuant to Public Resources Code,Section 21031.6. <br /> F.Any additional information concerning the design and operation of this facility must be provided upon request of the Local Enforcement Agency. <br /> G.This permit is subject to review by the LEA and may be suspended,revoked,or modified at any time for sufficient cause. <br /> H.This facility must conform to the Report of Disposal Site Information dated October of 1993 and the revised sections provided 211999. <br /> I.The LEA reserves the right to suspend or modify waste receiving operations when deemed necessary due to an emergency,an actual or potential hazard,or creation of <br /> a public nuisance. <br /> J.Any change that would cause a design or operation of this facility not to conform to the terms and conditions of this permit is prohibited.Such a change may be <br /> considered a significant change requiring a permit revision.In no case shall the operator implement any change without submitting a written notice of the proposed <br /> change to the LEA at least 120 days in advance of that change. <br /> K.Safety equipment shall be provided for all employees at the landfill. <br /> L.This facility must comply with the conditions of approval for the land use permit UP-91-12. <br /> M.The operator shall maintain a copy of this permit at the facility to be available at all times to facility personnel and enforcement agency personnel. <br /> N.A change in the operator of this facility shall require a new permit. <br /> O.The Grifolyn TX-1200(fire Retardant)synthetic blanket,or equivalent as approved by the LEA,is the only synthetic blanket approved for use at this facility. <br /> P.Six inches of soil cover material shall be applied at the end of each operating week to the active face where the Griffolyn TX-1200(fire retardant)synthetic blanket f <br /> was used. <br /> I <br /> Q.An adequate supply of water or soil shall be kept near the active face to aid in fire suppression. <br /> R.Application and removal of the synthetic blanket shall be done so as to minimize damage(punctures,tears,ect.)to the synthetic blanket. <br /> S.The operator shall remove from use and discard the synthetic blanket when it no longer functions as an adequate cover material as outlined in CIWMB's"Procedural <br /> Guidance For the Evaluation of Alternative Daily Cover". <br /> T.The LEA may order a synthetic blanket removed from service and discarded based on deteriorated condition(s)which prevent it form functioning as adequate cover. <br /> U.Griffolyn TX-1200(fire retardant)synthetic blanket may only be used to cover non-hazardous solid waste mixed with de-watered sewage or water treatment sludge at <br /> a minimum solid to liquid ratio of 5:1 by weight.The ultimate moisture holding capacity of the non-hazardous solid waste shall not exceeded. <br /> V,Griffolyn TX-1200(fire retardant)synthetic blanket shall not be used to cover designated waste,asbestos,or any other hazardous waste approved by DTSC for Class <br /> 11 or Class III disposal.Six inches of soil cover material still be used to cover these waste daily. <br />
The URL can be used to link to this page
Your browser does not support the video tag.