Laserfiche WebLink
10 RUL SUMPS-VAC PIPING -9.0 PSI <br /> 11 VAPOR LINE-DISP PAN -9.0 PSI <br /> 12 PUL PRODUCT -9.0 PSI <br /> 13 PUL SUMPS-VAC PIPING -9.0 PSI <br /> 14 RUL-PUL VENT-VENTBOX -9.0 PSI <br /> 15 DSL PRODUCT -9.0 PSI <br /> 16 DSL SUMPS-VAC PIPING -9.0 PSI <br /> 17 DSL VENT PIPING -9.0 PSI <br /> +AAM- <br /> +AAE- <br /> I61500 <br /> JUN 5, 2023 10:44 AM <br /> TANK PRODUCT LABEL METER DATA <br /> 1 RUL YES <br /> 2 PUL YES <br /> 3 DIESEL YES <br /> 4 NO <br /> +AAM- <br /> +AAE- <br /> I90200 <br /> JUN 5, 2023 10:44 AM <br /> SOFTWARE REVISION LEVEL <br /> VERSION 336.01 <br /> SOFTWARE+ACM- 346336-100-B <br /> CREATED - 20.04.26.20.30 <br /> S-MODULE+ACM- 330160-104-a <br /> SYSTEM FEATURES: <br /> PERIODIC IN-TANK TESTS <br /> ANNUAL IN-TANK TESTS <br /> BIR <br /> ISD/APM <br /> +AAM- <br /> +AAE- <br /> I11100 <br /> JUN 5, 2023 10:44 AM <br /> 872803 7-11 41216 <br /> 770 W CHARTER WAY <br /> STOCKTON CA 95206 <br /> V10274549505001 <br /> PRIORITY ALARM HISTORY <br /> ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME <br /> D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE CLEAR 6-05-23 10:35AM <br /> D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE ALARM 6-05-23 9:41AM <br /> L 2 PIPE RUL FILL SUMP SENSOR OUT ALARM CLEAR 6-05-23 9:27AM <br /> L 1 STP SUMP RUL STP SUMP SENSOR OUT ALARM CLEAR 6-05-23 9:27AM <br /> L14 DISP PAN DISP 11-12 PAN SENSOR OUT ALARM CLEAR 6-05-23 9:27AM <br /> L10 DISP PAN DISP 3-4 PAN SENSOR OUT ALARM CLEAR 6-05-23 9:27AM <br /> L13 DISP PAN DISP 9-10 PAN SENSOR OUT ALARM CLEAR 6-05-23 9:27AM <br /> L12 DISP PAN DISP 7-8 PAN SENSOR OUT ALARM CLEAR 6-05-23 9:27AM <br /> Lll DISP PAN DISP 5-6 PAN SENSOR OUT ALARM CLEAR 6-05-23 9:27AM <br /> L 9 DISP PAN DISP 1-2 PAN SENSOR OUT ALARM CLEAR 6-05-23 9:27AM <br /> L15 PIPE VENT SUMP SENSOR OUT ALARM CLEAR 6-05-23 9:27AM <br /> L 3 ANNULAR RUL ANNULAR SENSOR OUT ALARM CLEAR 6-05-23 9:27AM <br /> L 6 ANNULAR PUL-DSL ANNULAR SENSOR OUT ALARM CLEAR 6-05-23 9:27AM <br /> L 7 STP SUMP DSL STP SUMP SENSOR OUT ALARM CLEAR 6-05-23 9:27AM <br /> L 1 STP SUMP RUL STP SUMP SENSOR OUT ALARM ALARM 6-05-23 9:27AM <br /> L 5 PIPE PUL FILL SUMP SENSOR OUT ALARM CLEAR 6-05-23 9:27AM <br /> L 4 STP SUMP PUL STP SUMP SENSOR OUT ALARM CLEAR 6-05-23 9:27AM <br /> L 8 PIPE DSL FILL SUMP SENSOR OUT ALARM CLEAR 6-05-23 9:27AM <br /> L 1 STP SUMP RUL STP SUMP SENSOR OUT ALARM CLEAR 6-05-23 9:27AM <br /> L15 PIPE VENT SUMP SENSOR OUT ALARM ALARM 6-05-23 9:26AM <br /> L15 PIPE VENT SUMP SENSOR OUT ALARM CLEAR 6-05-23 9:26AM <br /> L 4 STP SUMP PUL STP SUMP SENSOR OUT ALARM ALARM 6-05-23 9:26AM <br />