SUMMARY OF THE CORRESPONDIIWALIFORNIA HEALTH AND SAFETY CO SECTIONS ARE PROVIDED BELOW.
<br />THIS SUMMARY PAGE LISTS THE GENERAL REQUIREMENT FOR EACH NUMBERED ITEM IN THE INSPECTION
<br />REPORT. THE DEPARTMENT MAY CITE ADDITIONAL SECTIONS AS APPLICABLE.
<br />REQUIREMENTS MARKED WITH AN ASTERISK ARE SPECIFIC TO TEMPORARY BODY ART FACILITIES
<br />Cleaning and Sterilization
<br />(1)
<br />Sterilization shall be accomplished pursuant to the
<br />procedures established by steam autoclave.
<br />§119315,§119321
<br />Instruments or other reusable items shall be
<br />washed, disinfected, packaged, and sterilized after
<br />each procedure. Packages shall contain either an
<br />integrator or temperature indicator and shall be
<br />labeled with name of instrument, date, and initials.
<br />Used, reusable instruments to be stored in liquid
<br />until cleaned and sterilized. An instrument or
<br />reusable item that does not come into contact with
<br />non -intact skin shall be washed, scrubbed and
<br />decontaminated after each procedure. §119309
<br />§119315
<br />Sterilizer shall be used and maintained according to
<br />.manufacturer's directions. §119315
<br />Autoclave shall be spore tested after initial
<br />installation, major repair, and at least once per
<br />month. Test results shall be recorded in a log. This
<br />log shall also contain date, contents, exposure time
<br />and temperature, results of Class V integrator for
<br />every cycle/load and when the biological test is
<br />positive — show a negative test before continued use
<br />& shall be kept on site for two years. §119315
<br />Decontamination/sterilization area is separated from
<br />procedure areas & supplied with a sink (hot and cold
<br />water, liquid soap & paper towels in a wall -mounted
<br />dispenser) that is readily accessible to practitioner,
<br />contains lined waste containers & sharps containers.
<br />Animals are not allowed. §119314
<br />*Decontamination area shall be separated from procedure areas
<br />by at least 5 feet or cleanable barrier. §119318
<br />6. A body art facility lacking a cleaning room &
<br />sterilization equipment shall use only disposable,
<br />single -use, pre -sterilized instruments & maintain
<br />records of purchase, use, procedures (include name
<br />of practitioner & client & procedure date). Keep
<br />records for at least 90 days. &119315
<br />*Adequate back up supplies available and stored appropriately
<br />for purchase by practitioners §119318
<br />7. Sharps containers are within arm's reach, labeled &
<br />disposed of by approved method. Sharps waste
<br />includes, needles & needle bars, hand tools if
<br />needle is part of unit (used to insert pigment),
<br />razors, etc. § 119311, § 119314
<br />*Sharps containers provided at each booth. Licensed medical
<br />waste disposal company retained for sharps pickup. §119318
<br />8. Jewelry, tattoo & piercing equipment shall be
<br />sterilized prior to use. Sterile packs shall be
<br />evaluated and if the integrity of a pack is
<br />compromised the pack shall be discarded or
<br />reprocessed before use. Only clean calipers shall
<br />be used. Disposable, single -use, presterilized stud
<br />and clasp only used for piercing ear. §119309,
<br />§119310,§119311,§119315
<br />Practitioner Health and Hygiene
<br />No food, drink, tobacco product, or personal effects
<br />are permitted in the procedure area. §119309
<br />10. Practitioner shall wash hands in approved manner
<br />before procedure & when soiled. §119301, §119308
<br />11 Hand washing sink in procedure area is supplied,
<br />has potable, warm water and is accessible. §119314
<br />"Practitioners shall have direct access to hand washing facilities
<br />(both permanently plumbed & individual stations). §119317,
<br />§119318
<br />12. Practitioner shall use appropriate personal protective
<br />equipment, including gloves, aprons, lap pads, etc.
<br />Gloves shall be worn throughout and if removed,
<br />hand hygiene performed before new gloves are
<br />donned. While branding appropriate protective face
<br />filter masks shall be worn by practitioner and client.
<br />119308, 119309
<br />*Eye wash station available for artist's use. §119318
<br />Customers/Clients
<br />13. Branding shall not be done with another client in the
<br />procedure area. §119309
<br />14. Clients shall be at least 18 years of age to receive a
<br />tattoo, permanent cosmetics application, a branding
<br />or body piercing (unless piercing in the presence of
<br />parent or guardian). §119302
<br />15. Skin shall be washed before shaved. Immediately
<br />prior to performing the body art, client's skin shall be
<br />prepared with an antiseptic solution, antimicrobial or
<br />microbicide, according to manufacturer's
<br />instructions. §119308
<br />96.Client's consent form and questionnaire includes all
<br />required components. §119303
<br />After care instructions includes all required
<br />components and are provided to client. §119308
<br />Tattoo and Permanent Cosmetic Machine Safety and
<br />Sanitation
<br />18. The machine shall be of a safe design with
<br />removable parts between the tip and motor housing
<br />to prevent backflow into the enclosed parts of the
<br />motor housing. §119311
<br />19. Wash and disinfect reusable instruments (machines,
<br />clip cords, etc.). §119308,§119309,§119311
<br />20. Grommets and elastic bands shall be discarded
<br />immediately upon completion of the procedure.
<br />§119311
<br />Continued on back of page 2