My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2023
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
EL DORADO
>
713
>
2300 - Underground Storage Tank Program
>
PR0521604
>
COMPLIANCE INFO_2023
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/11/2023 12:33:31 PM
Creation date
4/26/2023 3:21:41 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2023
RECORD_ID
PR0521604
PE
2371
FACILITY_ID
FA0014678
FACILITY_NAME
NATIONAL PETROLEUM
STREET_NUMBER
713
Direction
N
STREET_NAME
EL DORADO
STREET_TYPE
ST
City
STOCKTON
Zip
95202
APN
13905214
CURRENT_STATUS
01
SITE_LOCATION
713 N EL DORADO ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Environmental Health Department <br />Underground Storage Tank Program Inspection Report <br />Date: <br />May 30, 2023 <br /> Facility Address: <br /> 713 N EL DORADO ST, STOCKTON <br /> Facility Name: <br /> NATIONAL PETROLEUM <br />UST System Observations <br /> 311 □ V □ R □ COSMonitoring system incapable of detecting leak into secondary containment (pre-Jul 2003)HSC 2636(a)(1), <br />25291(b) <br /> 312 ■ V ■ R ■ COSMonitoring system incapable of detecting entry into secondary containment (Jul 2003-Jun 2004)HSC 25290.2(d) <br /> 313 □ V □ R □ COSMonitoring system incapable of detecting entry into secondary containment (post-Jul 2004)HSC 25290.1(d) <br /> 314 □ V □ R □ COSFailure to continuously monitor interstitial space with audible-visual alarm system (pre-Jul 2004)CCR 2631(g), 2632(c) <br />(2) <br /> 315 □ V □ R □ COSFailure to maintain interstitial space to detect leaks before release to environment (post-Jul 2004)HSC 25290.1(e) <br /> 316 □ V □ R □ COSFailure to install a line leak detectorCCR 2636, 2643(c)(1), <br />2666(f) <br /> 317 □ V □ R □ COSFailure of the line leak detector to detect a 3.0 gph leak at 10 psi and restrict or shut off flowCCR 2636(f)(2) <br /> 318 □ V □ R □ COSFailed to meet spill container requirementsCCR 2635, 2637.1, <br />2665, 2712 <br /> 319 □ V □ R □ COSFailure to comply with overfill prevention equipment requirementsCCR 2635, 2637.2, <br />2665, 2712 <br /> 320 □ V □ R □ COSOverfill prevention was overriddenCCR 2635(c)(1) <br /> 321 □ V □ R □ COSLeak detection equipment disabled or tampered withHSC 25299(a)(9) <br /> 322 □ V □ R □ COSRemoved, defaced, altered, or otherwise tampered with red tagCCR 2717.1(g) <br /> 323 □ V □ R □ COSDeposited or allowed deposit of petroleum or a hazardous substance into a red tagged USTCCR 2717.1(f); HSC <br />25292.3(c) <br /> 324 □ V □ R □ COSAllowed dispensing from a UST that has a red tag affixed to the fill pipeHSC 25292.3(c)(1)(C) <br /> 325 □ V □ R □ COSFailure to comply with the cathodic protection system requirementsCCR 2635, 2636(b), <br />2662, 2712 <br /> 326 □ V □ R □ COSPrimary and/or secondary containment not constructed in accordance with the established standardsCCR 2631(b&d), <br />2666(b&e) <br /> 327 □ V □ R □ COSLeak detection equipment not installed/calibrated/operated/maintained per manufacturer instructionsCCR 2638(a), 2641(j) <br /> 328 □ V □ R □ COSEquipment or methods used to monitor the UST system are not certified by an independent third-partyCCR 2630, 2632, 2643, <br />2644.1 <br /> 329 □ V □ R □ COSUST system not compatible with the substance storedCCR 2631.1, 2660(m) <br /> 330 □ V □ R □ COSFailure of emergency generator line leak detector to restrict or shut off flow or trigger an alarmCCR 2636(f), 2666(c), <br />2666(f) <br /> 331 □ V □ R □ COSFailure of unburied below-grade emergency generator system to meet exemption conditionsHSC 25281.6(a) <br /> 332 □ V □ R □ COSFailure of unburied below-grade UST system to meet exemption conditionsHSC 25283.5(a) <br /> 333 □ V □ R □ COSFailure to upgrade single-walled pipe to double-walled interstitially monitored pipe when repairedCCR 2666(b)(2) <br /> 334 □ V □ R □ COSFailure to comply with temporary closure requirementsCCR 2670(b)(e)(f), <br />2671 <br /> 335 □ V □ R □ COSFailure to comply with all permanent closure requirementsHSC 25298(c); CCR <br />2670, 2672 <br /> 336 □ V □ R □ COSFailure to affix a tag/sticker on each monitoring equipment certified, repaired, or replacedCCR 2638(f), 2641(j) <br />Single-Walled Non-Pressurized Piping <br /> 401 □ V □ R □ COSSafe suction piping failed to meet slope, check valve location, or inspection requirementsCCR 2636(a)(3), <br />2641(b) <br /> 402 □ V □ R □ COSFailure to conduct monitoring and maintain records for single-walled conventional suction (pre-1984)CCR 2643(d) <br /> 403 □ V □ R □ COSFailure to conduct 0.1 gph integrity test for single-walled conventional suction systems (pre-1984)CCR 2643(d), 2661(f) <br />FA0014678 PR0521604 SC001 05/30/2023 <br />EHD 23-01 Rev. 12/06/2021 Underground Storage Tank Program OIRPage 3 of 6 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD
The URL can be used to link to this page
Your browser does not support the video tag.