My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2023
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
R
>
REYNOLDS RANCH
>
2680
>
2300 - Underground Storage Tank Program
>
PR0535432
>
COMPLIANCE INFO_2023
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/18/2024 2:54:38 PM
Creation date
5/5/2023 2:53:35 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2023
RECORD_ID
PR0535432
PE
2351
FACILITY_ID
FA0020431
FACILITY_NAME
COSTCO WHOLESALE #1091
STREET_NUMBER
2680
STREET_NAME
REYNOLDS RANCH
STREET_TYPE
PKWY
City
LODI
Zip
95240
CURRENT_STATUS
01
SITE_LOCATION
2680 REYNOLDS RANCH PKWY
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\lsauers1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
124
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Lubrizol <br /> Version : <br /> Revision Date : 07/18/2023 <br /> mop <br /> Contaminants (29 CFR 1910 . 1000), as <br /> amended 02 2006 <br /> Toluene TWA 20 ppm US . ACGIH Threshold Limit Values , as <br /> amended 02 2012 <br /> Toluene STEL 150 ppm 560 mg/m3 US . NIOSH : Pocket Guide to Chemical <br /> Hazards , as amended 2010 <br /> Toluene REL 100 ppm 375 mg/m3 US . NIOSH : Pocket Guide to Chemical <br /> Hazards , as amended 2010 <br /> Toluene TWA 200 ppm US . OSHA Table Z-2 (29 CFR <br /> 1910 . 1000 ) , as amended 02 2006 <br /> Toluene Ceiling 300 ppm US . OSHA Table Z-2 (29 CFR <br /> 1910 . 1000) , as amended 02 2006 <br /> Toluene MAX. 500 ppm US . OSHA Table Z-2 (29 CFR <br /> CONC 1910 . 1000) , as amended 02 2006 <br /> Biological Limit Values <br /> Chemical name Exposure Limit Values Source <br /> Reaction mass of 1 . 5 g/g (Creatinine in urine ) ACGIH BEI (03 2013 ) <br /> ethylbenzene and xylene <br /> (Methylhippuric acids : <br /> Sampling time : End of <br /> shift. <br /> + + Ethyl benzene (Sum of 0 . 15 g/g (Creatinine in urine) ACGIH BEI (02 2014 ) <br /> mandelic acid and <br /> phenylglyoxylic acid : <br /> Sampling time: End of <br /> shift. <br /> Toluene (o-Cresol , with 0 . 3 mg/g (Creatinine in urine ) ACGIH BEI (03 2013 ) <br /> hydrolysis : Sampling time : <br /> End of shift . <br /> Toluene (toluene : 0 . 02 mg/I ( Blood ) ACGIH BEI (03 2013 ) <br /> Sampling time : Prior to <br /> as shift of workweek. ) <br /> Toluene (toluene : 0 .03 mg/I ( Urine) ACGIH BEI (03 2013 ) <br /> Sampling time : End of <br /> shift. <br /> Appropriate engineering Use explosion -proof ventilation equipment to stay below exposure limits . <br /> controls : Material should be handled in enclosed vessels and equipment , in which <br /> case general (mechanical ) room ventilation should be sufficient . Local <br /> exhaust ventilation should be used at points where dust, mist, vapors or <br /> gases can escape into the room air. Adequate ventilation should be <br /> provided so that exposure limits are not exceeded . <br /> Individual protection measures , such as personal protective equipment <br /> General information : Use explosion-proof ventilation equipment. Provide easy access to water <br /> supply and eye wash facilities . Good general ventilation (typically 10 air <br /> changes per hour) should be used . Ventilation rates should be matched to <br /> conditions . If applicable , use process enclosures , local exhaust ventilation , <br /> or other engineering controls to maintain airborne levels below <br /> recommended exposure limits . If exposure limits have not been <br /> established , maintain airborne levels to an acceptable level . Good general <br /> ventilation (typically 10 air changes per hour) should be used . Ventilation <br /> rates should be matched to conditions . Supplementary local exhaust <br /> ventilation , closed systems , or respiratory and eye protection may be <br /> needed in special circumstances , such as poorly ventilated spaces , <br /> heating , evaporation of liquids from large surfaces , spraying of mists , <br /> mechanical generation of dusts , drying of solids , etc . <br /> SDS US - ULTRAZOL® GA9058 7/ 19 <br />
The URL can be used to link to this page
Your browser does not support the video tag.