My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2023
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CHEROKEE
>
1721
>
2300 - Underground Storage Tank Program
>
PR0232355
>
COMPLIANCE INFO_2023
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/3/2023 11:09:42 AM
Creation date
5/17/2023 8:34:04 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2023
RECORD_ID
PR0232355
PE
2361
FACILITY_ID
FA0000591
FACILITY_NAME
QUIK STOP MARKET #551152
STREET_NUMBER
1721
Direction
S
STREET_NAME
CHEROKEE
STREET_TYPE
LN
City
LODI
Zip
95240
APN
062-060-48
CURRENT_STATUS
01
SITE_LOCATION
1721 S CHEROKEE LN #1
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
47
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
BELOW GROUND PRODUCTS www.opwgiobal.com <br /> OPW 400 and 500 <br /> Series Multi-Port Spill <br /> Containment Manholes <br /> OPW Multi-Port Spill Containment <br /> Manholes provide spill containment <br /> r for underground storage tank (UST) <br /> Con <br /> 400 61JSK fill pipes and vapor recovery risers in a <br /> completely integrated single manhole <br /> See page 65 for package. Multi-ports are installed over <br /> ordering specifications the top of tank sumps to preserve future <br /> the FSA 400&61JSK - �i <12:-_=:! + # , access to the tank top and to facilitate <br /> containment of tank bung fittings. OPW <br /> Model Descriptions Multi-Port Thread-On Spill containers offers a vast array of standard multi-port <br /> ♦ OPW 411 Series—features a flush- are available in Composite or Cast Iron configurations and options, in addition <br /> mounted manhole lid and raised dual bases with 5 gallon buckets. Drain to an almost unlimited ability to provide <br /> dam and groove spill container rings, Valve Spill Bucket& Plug Spill Bucket custom solutions for virtually any spill <br /> with P2105 Buckets using OPW 1-2105 standard on Dual Ports, Drain Valve containment application. <br /> Style Slip-On 5-gallon containers. Base Spill Bucket standard on Single Port. <br /> is standard 1" offset from center and ♦ Required for EVR APPLICATIONS <br /> can be used for 12", 14", 16" or wider —the FSA-400 Threaded Riser Face ♦ Spill Container Cover Options— <br /> riser spacing. Optional 1 P-2105 Hand Seal Adaptor is installed on the fill standard spill container options include <br /> Pump available. pipe below the spill container to the patented OPW dam and groove <br /> ♦ OPW 500 Series (511 / 521) EVR provide a true sealing for the drop raintight(RT) design and the <br /> Multi-Port—features a flush- <br /> tube flange on the 71 SO overfill watertight Sealable Cover(SC) <br /> " lumber's plug" design.The rainti ht <br /> mounted manhole lid and raised dual prevention valve.The 61 SO and/or p p g" 9 9 <br /> dam and groove spill container ring, 71 SO series valve is installed in the cover features a finger-grip lifting <br /> with P511-EVR Buckets using OPW base of the OPW EVR spill container facility and an integral seal.The <br /> 1-2100 Style Thread-On Spill with the patent pending 61 JSK jack sealable cover features a cam-operated <br /> Containers.All Fill Ports in these spill screw device.This configuration allows mechanism that expands the seal <br /> containers feature an enhanced liquid in the spill container to be against the vertical wall of the <br /> 1 DK-2100-EVR vapor tight drain valve. drained directly into the drop tube, mounting ring. Both of these water- <br /> The Vapor Return Spill Container thereby isolating the drain valve from shedding covers are protected by <br /> features a permanent plug in the drain the tank ullage,eliminating a notorious raised mounting rings. <br /> port as per EVR requirements. EVR leak point in previous systems. ♦ Fastener Options—two types of <br /> fasteners are available to secure the <br /> Features ♦ Fill/Vapor Ports-configurations are manhole lid and monitoring port to <br /> mounting rings. Standard are <br /> available to accommodate a single fill 5/16"-18 hex head bolts.Optional <br /> Contractor-Friendly Installation riser, dual ports for both a fill and p <br /> -studded mounting ring simply bolts vapor riser,and triple and quad ports are OPW Roto-Lock Fasteners. <br /> together inside the spill containment for multiple fill and vapor risers. Ports The OPW Roto-Lock system enables a <br /> bucket. No need to align bolt holes in can be supplied with or without secure,watertight connection without <br /> the manhole cover. containment buckets. the need to locate threaded bolt holes <br /> 400- Raintight Service-nitrile gaskets ♦ on the mounting ring.port Configurations-standard port 01, Powder Coated Rings & Covers- <br /> on the manhole and spill bucket locations match the popular riser <br /> mounting rings help prevent spacings (16" or 24") and bung available upon request. <br /> contamination of the sump area configurations on underground storage ♦ Replacement Covers-see Part <br /> from surface water intrusion. tanks. Custom port locations are easily Number Configurations at <br /> ♦ Highway 20 Load Rating-the accommodated. For riser spacings less www.opwgiobal.com. <br /> rugged diamond plate steel manhole than 16", old style buckets must <br /> covers,as well as the ductile iron (RT) be used. Listings and Certifications <br /> or aluminum (SC) spill container covers ♦ CARB Certified-500 Series CARB <br /> meet H2O Load Rating requirements. EVR Approved Executive Order#VR-102 Look for this label for <br /> ♦ Spill Container and Manhole ♦ Manhole Cover Sizes-standardULC authentic OPW EVR <br /> Positive I.D. System-special bolt-down manhole cover diameters Approved products. <br /> recesses cast into spill container covers of 30" (76 cm),37" (94 cm),42" C3tl "' <br /> allow product I.D.tags to be attached (107 cm) and 48" (122 cm) allow CARB EVR Executive Order#VR-102 <br /> to the lids. Matching bucket tags can ample access to the sump area. Heavy- NYCFD Certified(6571 Series)#5053 <br /> be affixed to the inside of the spill duty reinforced lid options are also Florida EQ-145 <br /> container to prevent covers from available upon request. <br /> getting switched. <br />