Laserfiche WebLink
Percolation Test <br /> A shallow percolation test was conducted at the test location. The soil boring discussed <br /> above was used for the percolation test hole. Percolation test procedures conformed to <br /> San Joaquin County Environmental Health Department policy. <br /> Preparation and Presaturation of Percolation Test Holes <br /> After the boring was advanced by hand auger and the soil logged, the test hole was <br /> completed for the percolation testing. Approximately two inches of pea gravel were <br /> placed in the bottom of the open soil boring, followed by a 2.0-inch diameter PVC pipe <br /> with perforations on the bottom. Pea gravel was then used to backfill a few inches of the <br /> annular space. <br /> Live Oak presaturated the percolation test hole approximately 24 hours prior to the <br /> percolation testing. The hole was filled with water to a height of 12 inches above the <br /> bottom of the boring for the presaturation. On the day of testing, the hole was found to <br /> be intact and dry. <br /> Percolation Test Procedure <br /> Live Oak conducted the percolation test for the boring on April 27, 2023. Based on the <br /> soil type present, a standard four-hour test was selected. Water level measurements <br /> were taken every 30 minutes during the four-hour period. The last 30 minutes of the test <br /> were observed by Naseem Ahmed, Senior Registered Environmental Health Specialist <br /> at the San Joaquin County Environmental Health Department. <br /> An electronic well sounder with a depth accuracy of 1/100th foot was utilized for the water <br /> level measurements. The water level was measured against a fixed reference point on <br /> the well casing. Measurements were recorded on the data sheet in decimal feet. When <br /> necessary after measuring the water level, the hole was refilled with water to a level of <br /> approximately six inches above the bottom of the hole. <br /> Percolation Test Results <br /> The completed percolation test form is included in Appendix 3 of this report. The form <br /> was signed by Mr. Ahmed and indicates a percolation rate for the hole based on the final <br /> water drop observed. <br /> Per San Joaquin County Environmental Health Department's definition, a shallow <br /> percolation test hole has a depth between 18 and 42 inches; a satisfactory percolation <br /> rate for a shallow test is greater than or equal to 1 minute per inch (min/in) but less than <br /> or equal to 60 min/in drop. For the Site to utilize a standard septic system, one percolation <br /> test hole must demonstrate a satisfactory percolation rate within the proposed septic <br /> system disposal field. <br /> LOGE 2312 Page 6 <br />