Laserfiche WebLink
Because ground water is so deep in the area (85 to 95 feet bgs), there is potential for <br /> significant nitrate attenuation before the effluent reaches ground water. Clay-containing <br /> soils, like those observed on the Site, also tend to inhibit downward movement of nitrate <br /> due to adsorption of the nitrate ions to the soil. <br /> Sources of Nitrate <br /> Dairies, orchards that require fertilization in sandy soils, and septic systems have been <br /> found to be the most significant sources of nitrate in ground water. <br /> Percolating Recharge Waters <br /> One of the most determinant factors in the Hantzsche and Finnemore equation is the rate <br /> of recharge from percolating waters, which mix with the downward-percolating effluent <br /> generated by on-site septic systems. In the original Hantzsche and Finnemore paper, <br /> "average recharge rate of rainfall" was utilized. <br /> Based on San Joaquin County Environmental Health Department policy (personal <br /> communication, March 18, 2019), the recharge input for the Hantzsche and Finnemore <br /> equation should be derived from average monthly precipitation of rainfall and <br /> evapotranspiration rates for the area; the data should be obtained from the California <br /> Irrigation Management Information System (CIMIS). Recharge is calculated by first <br /> determining whether the average monthly precipitation exceeds average monthly <br /> potential evapotranspiration. If so, then the difference is the percolating recharge water <br /> into the aquifer. Runoff and stream infiltration drainage are not factored into the <br /> calculation. This approach likely under-estimates recharge to the aquifer and, <br /> consequently, over-estimates nitrate loading. <br /> The closest CIMIS station to the Site is Staten Island (station 242). Data for the Staten <br /> Island station were available for the past seven years; based on the calculation shown, <br /> the estimated rate of recharge from percolating waters for the Staten Island station is <br /> determined to be 8.51 inches (Plate 14). A statistical error of 72 percent is associated <br /> with this value. <br /> Quality of Rainwater <br /> Hantzsche and Finnemore listed 1 mg/L-N as the nitrate concentration of rainwater for <br /> their original calculation; in the past, Live Oak has also utilized this value for the nitrate <br /> loading calculation. <br /> To determine a more accurate local value, Live Oak has collected rainwater during 14 <br /> recent storm events in Lodi. Each sample was collected in a clean, dry, stainless steel <br /> bowl, then decanted into a plastic container and placed on ice for transport. The samples <br /> were analyzed for nitrate by FGL Environmental of Stockton. The results of the rainwater <br /> sampling are as follows: <br /> LOGE 2312 Page 9 <br />