Laserfiche WebLink
Environmental Health Department <br />Time In: <br />10:20 am <br /> 9:40 am <br />Time Out: <br />Program Element: 3611 - PUBLIC POOL/SPA - PRIMARY <br />Telephone: (209) 497-8220 Owner/Operator: BROOKSIDE MASTER ASSN <br />Inspection Type: ROUTINE INSPECTION - Operating Permit <br />Address: 3536 BROOKVIEW DR, STOCKTON 95219 <br />Date: 05/31/2023Name of Facility: CLUB BROOKSIDE HOMEONWERS ASSN <br />Swimming Pool Official Inspection Report <br />VIOLATIONS AND CORRECTIVE ACTIONS <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public health <br />and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br /> #10 Disinfectant Residual MAJOR <br />OBSERVATIONS: Free chlorine is above 10 ppm. Adjust to 2 ppm to 10 ppm. This was corrected on site. Free chlorine <br />was 9 ppm after correction. <br />CALCODE DESCRIPTION: Public pools, when open or in use, shall be disinfected continuously by approved chemicals and shall maintain <br />the following concentrations: 1.0 ppm to 10.0 ppm free chlorine without cyanuric acid, 2.0 ppm to 10.0 ppm free chlorine with cyanuric acid <br />or 2.0 ppm bromine. Spas, wading pools, and spray grounds shall maintain the following concentrations: 3.0 ppm to 10.0 ppm free <br />chlorine or 4.0 ppm bromine. (CCR 65529) <br /> #22 Skimmer Assembly <br />OBSERVATIONS: Two float assemblies and several weirs and o-rings were lacking in the skimmers. Install/provide all <br />parts to the skimmers. Correct today. (REPEAT) <br />CALCODE DESCRIPTION: Pool shall be equipped to provide continuous skimming of the pool water. All parts of the skimmer shall be <br />maintained in accordance with manufacturer specifications. (CBC 3136B) <br /> #36 Pressure and Vacuum Gauges <br />OBSERVATIONS: One influent gauge was observed non-operational with liquid inside the gauge. Repair/replace today. <br />(REPEAT) <br />CALCODE DESCRIPTION: Pressure and vacuum gauges shall be provided for each pump system. (CBC 3125B) <br />OVERALL INSPECTION NOTES AND COMMENTS <br />OBSERVATIONS <br />Flow rate:gpm <br />pH: <br />Chlorine:ppm <br />Cyanuric acid:ppm <br />Temp:º F 100 <br />7.2 <br />>10 <br />70 Combined chlorine:ppm <br />NOTES <br />Pool <br />Influent 21/18/0/10/10 psi <br />Page 1 of 2EHD 36-01 Rev. 09/16/2020 Swimming Pool OIR <br />FA0004629 PR0500132 SC001 05/31/2023 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD