Environmental Health Department <br />Time In: <br />12:36 pm <br />12:12 pm <br />Time Out: <br />Program Element: 3612 - PUBLIC POOL/SPA - ADDITIONAL <br />Telephone: Owner/Operator: VALENCIA PLACE PARTNERS LLC <br />Inspection Type: ROUTINE INSPECTION - Operating Permit <br />Address: 717 W ATHERTON DR, MANTECA 95337 <br />Date: 06/07/2023Name of Facility: THE ATHERTON APARTMENTS <br />Swimming Pool Official Inspection Report <br />VIOLATIONS AND CORRECTIVE ACTIONS <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public health <br />and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br /> #10 Disinfectant Residual MAJOR <br />OBSERVATIONS: Free chlorine is at 1 ppm. Provide 3 ppm - 10 ppm today. Chlorine is added to the spa. Rechecking the <br />free chlorine and it is at 6.6 ppm. Corrected on site. <br />CALCODE DESCRIPTION: Public pools, when open or in use, shall be disinfected continuously by approved chemicals and shall maintain <br />the following concentrations: 1.0 ppm to 10.0 ppm free chlorine without cyanuric acid, 2.0 ppm to 10.0 ppm free chlorine with cyanuric acid <br />or 2.0 ppm bromine. Spas, wading pools, and spray grounds shall maintain the following concentrations: 3.0 ppm to 10.0 ppm free <br />chlorine or 4.0 ppm bromine. (CCR 65529) <br /> #3 Safety Signs <br />OBSERVATIONS: Capacity sign is fading. Post spa capacity sign today. <br />CALCODE DESCRIPTION: Pool operator shall keep safety signs well maintained. (CCR 65535) Safety signs shall have clearly legible <br />letters or numbers not less than 4 inches high, unless otherwise specified. Safety signs shall be affixed to a wall, pole, gate, or similar <br />permanent structure in a location visible to all pool users, unless otherwise specified. (CBC 3120B) <br /> #22 Skimmer Assembly <br />OBSERVATIONS: Spa skimmer is lacking 3 float valve and a weir gate. Provide float valve and weir gate today. <br />CALCODE DESCRIPTION: Pool shall be equipped to provide continuous skimming of the pool water. All parts of the skimmer shall be <br />maintained in accordance with manufacturer specifications. (CBC 3136B) <br /> #36 Pressure and Vacuum Gauges <br />OBSERVATIONS: Spa pump is lacking Effluent pressure gauge. Provide gauge in 1 week. <br />CALCODE DESCRIPTION: Pressure and vacuum gauges shall be provided for each pump system. (CBC 3125B) <br />OVERALL INSPECTION NOTES AND COMMENTS <br />OBSERVATIONS <br />Flow rate:gpm <br />pH: <br />Chlorine:ppm <br />Cyanuric acid:ppm <br />Temp:º F 100 <br />7.2 <br />1 <br /><30 Combined chlorine:ppm <br />Page 1 of 2EHD 36-01 Rev. 09/16/2020 Swimming Pool OIR <br />FA0026523 PR0546829 SC001 06/07/2023 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD