Environmental Health Department <br />Time In: <br />10:15 am <br /> 9:40 am <br />Time Out: <br />Program Element: 3611 - PUBLIC POOL/SPA - PRIMARY <br />Telephone: Owner/Operator: ZAKARIA, STEVEN <br />Inspection Type: ROUTINE INSPECTION - Operating Permit <br />Address: 1090 N MAIN ST, MANTECA 95336 <br />Date: 06/15/2023Name of Facility: CALFIT MANTECA INC <br />Swimming Pool Official Inspection Report <br />VIOLATIONS AND CORRECTIVE ACTIONS <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public health <br />and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br /> #9 Ladders and Handrails <br />OBSERVATIONS: Left single hand rail is not secured. Secure hand rail in 1 week. <br />CALCODE DESCRIPTION: A means of entry and exit shall be provided at both the shallow and deep end of the pool. Ladders and <br />handrails shall be corrosion resistant and shall be rigidly installed. At least one handrail shall extend from the deck to not less than a point <br />above the top of the lowest step. Handrails shall be installed between 28 to 36 inches above the steps and deck. (CBC 3111B) Pool <br />operator shall keep ladders and handrails well maintained. (CCR 65535) <br /> #22 Skimmer Assembly <br />OBSERVATIONS: 2 skimmers are lacking weir gates. Provide weir gates in 1 week. <br />CALCODE DESCRIPTION: Pool shall be equipped to provide continuous skimming of the pool water. All parts of the skimmer shall be <br />maintained in accordance with manufacturer specifications. (CBC 3136B) <br /> #35 Flow Meters <br />OBSERVATIONS: Flow meter is not installed. Provide flow meter in 1 week. <br />CALCODE DESCRIPTION: Flow meters shall be provided on each recirculation system and shall be installed in accordance with <br />manufacturer's specifications. (CBC 3125B) <br /> #36 Pressure and Vacuum Gauges <br />OBSERVATIONS: Pool effluent gauge is not available. Provide new gauge in 1 week. <br />CALCODE DESCRIPTION: Pressure and vacuum gauges shall be provided for each pump system. (CBC 3125B) <br />OVERALL INSPECTION NOTES AND COMMENTS <br />OBSERVATIONS <br />Flow rate:gpm <br />pH: <br />Chlorine:ppm <br />Cyanuric acid:ppm <br />Temp:º F <br />7.4 <br />7.2 <br /><30 Combined chlorine:ppm <br />NOTES <br />Page 1 of 2EHD 36-01 Rev. 09/16/2020 Swimming Pool OIR <br />FA0007124 PR0505983 SC001 06/15/2023 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD