Laserfiche WebLink
Environmental Health Department <br />Time In: <br />11:40 am <br />11:05 am <br />Time Out: <br />Program Element: 3611 - PUBLIC POOL/SPA - PRIMARY <br />Telephone: Owner/Operator: STONE BROS AND ASSOCIATES <br />Inspection Type: ROUTINE INSPECTION - Operating Permit <br />Address: 5650 STRATFORD CIR, STOCKTON 95207 <br />Date: 06/16/2023Name of Facility: ROBINHOOD MANOR APARTMENTS <br />Swimming Pool Official Inspection Report <br />VIOLATIONS AND CORRECTIVE ACTIONS <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public health <br />and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br /> #3 Safety Signs <br />OBSERVATIONS: A safety sign containing the address of the facility is lacking. All safety signs shall be posted. Correct <br />today. (REPEAT) <br />CALCODE DESCRIPTION: Pool operator shall keep safety signs well maintained. (CCR 65535) Safety signs shall have clearly legible <br />letters or numbers not less than 4 inches high, unless otherwise specified. Safety signs shall be affixed to a wall, pole, gate, or similar <br />permanent structure in a location visible to all pool users, unless otherwise specified. (CBC 3120B) <br /> #18 Pool Shell and Tile <br />OBSERVATIONS: The pool shell was observed with minor pitting on the side. Plan to have pool re-plastered in the future. <br />CALCODE DESCRIPTION: Pool shells shall be white and have a smooth waterproof interior finish that will withstand repeated brushing, <br />and scrubbing. A spa pool may be finished in a light color other than white when approved by the enforcement agency. (CBC 3108B) <br /> #22 Skimmer Assembly <br />OBSERVATIONS: The skimmers are lacking two weirs and two o-rings. Install all parts to the skimmers within two weeks. <br />(REPEAT) <br />CALCODE DESCRIPTION: Pool shall be equipped to provide continuous skimming of the pool water. All parts of the skimmer shall be <br />maintained in accordance with manufacturer specifications. (CBC 3136B) <br /> #35 Flow Meters <br />OBSERVATIONS: The flow meter is not functioning. Replace/repair today. <br />CALCODE DESCRIPTION: Flow meters shall be provided on each recirculation system and shall be installed in accordance with <br />manufacturer's specifications. (CBC 3125B) <br />OVERALL INSPECTION NOTES AND COMMENTS <br />OBSERVATIONS <br />Flow rate:gpm <br />pH: <br />Chlorine:ppm <br />Cyanuric acid:ppm <br />Temp:º F <br />7.6 <br />3.6 <br /><30 Combined chlorine:ppm <br />Page 1 of 2EHD 36-01 Rev. 09/16/2020 Swimming Pool OIR <br />FA0002170 PR0360121 SC001 06/16/2023 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD