Laserfiche WebLink
Environmental Health Department <br />Time In: <br /> 8:45 am <br /> 8:17 am <br />Time Out: <br />Program Element: 3611 - PUBLIC POOL/SPA - PRIMARY <br />Telephone: Owner/Operator: CHESAPEAKE LANDING HOA <br />Inspection Type: ROUTINE INSPECTION - Operating Permit <br />Address: 1660 N RED SKY , RIPON 95366 <br />Date: 06/21/2023Name of Facility: CHESAPEAKE LANDING HOA POOL <br />Swimming Pool Official Inspection Report <br />VIOLATIONS AND CORRECTIVE ACTIONS <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public health <br />and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br /> #10 Disinfectant Residual MAJOR <br />OBSERVATIONS: Free chlorine is at 1 ppm. Provide free chlorine 2 ppm - 10 ppm today. Corrected on site. Free chlorine is <br />at 4.2 now. <br />CALCODE DESCRIPTION: Public pools, when open or in use, shall be disinfected continuously by approved chemicals and shall maintain <br />the following concentrations: 1.0 ppm to 10.0 ppm free chlorine without cyanuric acid, 2.0 ppm to 10.0 ppm free chlorine with cyanuric acid <br />or 2.0 ppm bromine. Spas, wading pools, and spray grounds shall maintain the following concentrations: 3.0 ppm to 10.0 ppm free <br />chlorine or 4.0 ppm bromine. (CCR 65529) <br /> #12 pH Level MAJOR <br />OBSERVATIONS: pH is >8. Provide pH 7.2 - 7.8 today. Corrected on site. pH is 7.6 now. <br />CALCODE DESCRIPTION: Pool operator shall maintain pH between 7.2 and 7.8. (CCR 65530) <br /> #9 Ladders and Handrails <br />OBSERVATIONS: Left handle of the double handrail is not secured. Secure handrail in 1 week. <br />CALCODE DESCRIPTION: A means of entry and exit shall be provided at both the shallow and deep end of the pool. Ladders and <br />handrails shall be corrosion resistant and shall be rigidly installed. At least one handrail shall extend from the deck to not less than a point <br />above the top of the lowest step. Handrails shall be installed between 28 to 36 inches above the steps and deck. (CBC 3111B) Pool <br />operator shall keep ladders and handrails well maintained. (CCR 65535) <br />OVERALL INSPECTION NOTES AND COMMENTS <br />OBSERVATIONS <br />Flow rate:gpm <br />pH: <br />Chlorine:ppm <br />Cyanuric acid:ppm <br />Temp:º F 75 <br />>8 <br />1 <br /><30 Combined chlorine:ppm <br />NOTES <br />Pool inspection. <br />Influent 28 PSI <br />Effluent 20 PSI <br />Life ring and body hook on site. <br />Lights and GFCI are working. <br />Page 1 of 2EHD 36-01 Rev. 09/16/2020 Swimming Pool OIR <br />FA0014806 PR0521805 SC001 06/21/2023 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD