My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2023
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
EL DORADO
>
8003
>
3600 - Recreational Health Program
>
PR0360348
>
COMPLIANCE INFO_2023
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/28/2023 5:02:04 PM
Creation date
6/27/2023 10:11:21 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3600 - Recreational Health Program
File Section
COMPLIANCE INFO
FileName_PostFix
2023
RECORD_ID
PR0360348
PE
3611
FACILITY_ID
FA0002717
FACILITY_NAME
BIRCHES APARTMENTS
STREET_NUMBER
8003
Direction
N
STREET_NAME
EL DORADO
STREET_TYPE
ST
City
STOCKTON
Zip
95210
APN
07935041
CURRENT_STATUS
01
SITE_LOCATION
8003 N EL DORADO ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
4
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
`'.. ll � � �A�] I N Environmental Health Department <br /> `- Irl +lJ <br /> L.. v•:v COUNTY <br /> .r{ � 7fa�p[r+85S grows hire, Time In: 10.30 am <br /> Time Out: 11:15 am <br /> Swimming Pool Official Inspection Report <br /> Name of Facility: BIRCHES APARTMENTS Date: 05/31/2023 <br /> Address: 8003 N ELDORADO ST, STOCKTON 95210 <br /> Owner/Operator: BIRCHES INVESTORS LP Telephone: <br /> Program Element: 3611 -PUBLIC POOL/SPA-PRIMARY <br /> Inspection Type: ROUTINE INSPECTION -Operating Permit <br /> VIOLATIONS AND CORRECTIVE ACTIONS <br /> Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s)116043, 116040,& <br /> 116050. All violations must be corrected within specified timeframe. Violations that are classified as"MAJOR"pose an immediate threat to public health <br /> and must be corrected immediately or be subject to closure pursuant to California Code of Regulations(Title 22)section 65545. <br /> #1 Pool Gates MAJOR <br /> OBSERVATIONS:The pool gate was not closing fully and it did not self-latch. Pool was currently closed. Keep pool closed <br /> until gate door is fully self-closing and self-latching and correction is verified by EHD. <br /> CALCODE DESCRIPTION:Gates and doors leading into the pool area shall be equipped with self-closing self-latching devices. <br /> Self-latching devices shall be designed to keep the gate or door securely closed. Gates and doors shall open outward from the pool area <br /> except where otherwise prohibited by law. (CBC 31198) Pool operator shall keep gates and doors leading into the pool area well <br /> maintained. (CCR 65535) <br /> #3 Safety Signs <br /> OBSERVATIONS:Lacking max pool capacity on safety sign. Provide max pool capacity today. <br /> CALCODE DESCRIPTION:Pool operator shall keep safety signs well maintained. (CCR 65535)Safety signs shall have clearly legible <br /> letters or numbers not less than 4 inches high, unless otherwise specified. Safety signs shall be affixed to a wall,pole,gate, or similar <br /> permanent structure in a location visible to all pool users, unless otherwise specified. (CBC 31208) <br /> #7 Pool Deck <br /> OBSERVATIONS:Observed vegetation growth on pool deck. Remove and maintain pool deck free of vegetation. <br /> Observed gaps in pool deck. Repair/seal gaps so that pool deck is free of trip hazards. <br /> CALCODE DESCRIPTION:An unobstructed 4-foot wide deck of concrete or like material shall be provided and maintained flush with the <br /> top of the pool coping. Deck shall extend completely around the pool and shall further extend 4 feet on both sides and to the rear of any <br /> diving board,ADA device, or slide. (CBC 31146)Pool operator shall keep the pool deck well maintained. (CCR 65535) <br /> #22 Skimmer Assembly <br /> OBSERVATIONS:Observed debris in skimmer baskets. Clean today and maintain <br /> Both skimmers were missing weirs. Provide weirs for skimmers today. <br /> CALCODE DESCRIPTION:Pool shall be equipped to provide continuous skimming of the pool water. All parts of the skimmer shall be <br /> maintained in accordance with manufacturer specifications. (CBC 31366) <br /> FA0002717 PR0360348 SCO01 05/31/2023 <br /> EHD 36-01 Rev.09/16/2020 Page 1 of 2 Swimming Pool OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />
The URL can be used to link to this page
Your browser does not support the video tag.