Laserfiche WebLink
S A N J O a Q U I N Environmental Health Department <br /> Swimming Pool Official Inspection Report <br /> Facility Name and Address: BIRCHES APARTMENTS, 8003 N EL DORADO ST, STOCKTON 95210 <br /> #7 Pool Deck <br /> OBSERVATIONS:Observed vegetation growth on pool deck. Remove and maintain pool deck free of vegetation. <br /> Observed damaged lid for compartment next to deep end skimmer. Replace lid today. <br /> Observed gaps in pool deck between coping and expansion joints. Observed gap between coping at deep end of pool near <br /> skimmer and gap between pool deck pads near shallow hand rail. Repair/seal gaps so that pool deck is free of trip hazards. <br /> CALCODE DESCRIPTION:An unobstructed 4-foot wide deck of concrete or like material shall be provided and maintained flush with the <br /> top of the pool coping. Deck shall extend completely around the pool and shall further extend 4 feet on both sides and to the rear of any <br /> diving board,ADA device, or slide. (CBC 3114B)Pool operator shall keep the pool deck well maintained. (CCR 65535) <br /> #17 Cleanliness of Pool <br /> OBSERVATIONS:Observed debris on bottom of pool. Clean and maintain pool free of debris. <br /> CALCODE DESCRIPTION:Pool operator shall maintain clean pool water while the pool is in use and shall not allow debris to accumulate <br /> in the pool. Pool operator shall clean the bottom, sides,and other surfaces of the pool as often as necessary to keep pool surfaces clean <br /> and free of slime and algae. (CCR 65533) <br /> #22 Skimmer Assembly <br /> OBSERVATIONS:Observed debris in skimmer baskets. Clean and maintain clean. <br /> The shallow end skimmer was missing a weir. Provide weir today. <br /> CALCODE DESCRIPTION:Pool shall be equipped to provide continuous skimming of the pool water. All parts of the skimmer shall be <br /> maintained in accordance with manufacturer specifications. (CBC 3136B) <br /> #35 Flow Meters <br /> OBSERVATIONS:The flow meter was stuck. Provide working flow meter today. <br /> CALCODE DESCRIPTION:Flow meters shall be provided on each recirculation system and shall be installed in accordance with <br /> manufacturer's specifications. (CBC 3125B) <br /> OVERALL INSPECTION NOTES AND COMMENTS <br /> OBSERVATIONS <br /> Flow rate: gpm Chlorine: ppm Temp: ° F <br /> Cyanuric acid: ppm pH: Combined chlorine: ppm <br /> NOTES <br /> Re-inspection. <br /> Influent: 15 PSI <br /> Effluent: 10 PSI <br /> Pool light ok. <br /> Keep pool closed until pool gate correction is verified by EHD. Call 209-616-3035 to schedule re-inspection when ready or <br /> email evidence of correction to dafonskaia@sjgov.org <br /> FA0002717 PR0360510 SC333 06/01/2023 <br /> EHD 36-01 Rev.09/16/2020 Page 2 of 3 Swimming Pool OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />