Laserfiche WebLink
Environmental Health Department <br />Facility Name and Address: BEST WESTERN, 6411 W BANNER ST, LODI 95242 <br />Swimming Pool Official Inspection Report <br /> #14 Chemical Water Test Kit <br />OBSERVATIONS: Lacking pool chemical test kit. Provide today. <br />CALCODE DESCRIPTION: Pool operator shall maintain a test kit for measuring the disinfectant residual, combined chlorine, pH, and <br />cyanuric acid (if used) at the pool. Test kit shall be available at all times the pool is in use. Chlorine and bromine test kits shall be DPD <br />type. Chlorine test kits shall be capable of testing for free and total chlorine, so that combined chlorine concentrations can be determined. <br />(CCR 65529) <br /> #15 Operation Records <br />OBSERVATIONS: Pool testing records were not maintained. Maintain daily chlorine and pH testing and monthly cyanuric <br />acid testing records. <br />CALCODE DESCRIPTION: Pool operator shall test the disinfectant residual, pH, and spa water temperature a minimum of once per day. <br />Cyanuric acid concentration shall be tested once per month if cyanuric acid is used. Combined chlorine shall be tested as often as <br />necessary to maintain the concentration below 0.4 ppm. Pool operator shall maintain written records of all maintenance and test results <br />for at least two years and shall submit those records to the enforcement agency upon request. (CCR 65523) <br /> #27 Pool Equipment Room <br />OBSERVATIONS: Observed water on ground around pool pump and filter. Clean today and repair leaking as necessary. <br />CALCODE DESCRIPTION: Pool operator shall keep ancillary facilities well maintained. (CCR 65535) All filters, valves, pumps, strainers <br />and equipment shall be readily accessible for repair and replacement. (CBC 3123B) <br /> #35 Flow Meters <br />OBSERVATIONS: The flow meter was stuck. Provide working flow meter today. <br />CALCODE DESCRIPTION: Flow meters shall be provided on each recirculation system and shall be installed in accordance with <br />manufacturer's specifications. (CBC 3125B) <br />OVERALL INSPECTION NOTES AND COMMENTS <br />OBSERVATIONS <br />Flow rate:gpm <br />pH: <br />Chlorine:ppm <br />Cyanuric acid:ppm <br />Temp:º F <br />>8.0 <br />>100 <br /><30 Combined chlorine:ppm <br />NOTES <br />Influent: 19 PSI <br />Effluent: 11 PSI <br />Pool light and safety equipment ok. <br />Skimmer lid was screwed shut during the inspection, unable to check skimmer during the inspection. <br />Keep pool closed until chlorine and pH corrections are verified by EHD. Call 209-616-3035 or 209-468-3420 to schedule <br />re-inspection. <br />Page 2 of 3EHD 36-01 Rev. 09/16/2020 Swimming Pool OIR <br />FA0016226 PR0524150 SC001 06/19/2023 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD