Laserfiche WebLink
Environmental Health Department <br />Time In: <br />10:21 am <br /> 9:55 am <br />Time Out: <br />Program Element: 3611 - PUBLIC POOL/SPA - PRIMARY <br />Telephone: (209) 858-1234 Owner/Operator: N & J HOTEL MANAGEMENT LLC <br />Inspection Type: ROUTINE INSPECTION - Operating Permit <br />Address: 16855 S HARLAN RD, LATHROP 95330 <br />Date: 06/22/2023Name of Facility: QUALITY INN & SUITES <br />Swimming Pool Official Inspection Report <br />VIOLATIONS AND CORRECTIVE ACTIONS <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public health <br />and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br /> #3 Safety Signs <br />OBSERVATIONS: The safety signage is faded. Replace safety signage by 1 week. <br />CALCODE DESCRIPTION: Pool operator shall keep safety signs well maintained. (CCR 65535) Safety signs shall have clearly legible <br />letters or numbers not less than 4 inches high, unless otherwise specified. Safety signs shall be affixed to a wall, pole, gate, or similar <br />permanent structure in a location visible to all pool users, unless otherwise specified. (CBC 3120B) <br /> #7 Pool Deck <br />OBSERVATIONS: The "No Diving" tile is missing at the deep end pool deck. Replace missing deck tile by 1 week. <br />CALCODE DESCRIPTION: An unobstructed 4-foot wide deck of concrete or like material shall be provided and maintained flush with the <br />top of the pool coping. Deck shall extend completely around the pool and shall further extend 4 feet on both sides and to the rear of any <br />diving board, ADA device, or slide. (CBC 3114B) Pool operator shall keep the pool deck well maintained. (CCR 65535) <br /> #8 Pool and Deck Lighting <br />OBSERVATIONS: The pool light is burned out. Repair/replace the pool light by 1 week. <br />CALCODE DESCRIPTION: Pools used at night shall be equipped with underwater light fixtures that provide complete illumination of the <br />pool. When a pool is used at night, pool deck and emergency egress areas shall be provided with lighting. If underwater or deck lighting is <br />not operational, the pool operator shall post a sign in 4-inch letters stating "NO USE OF POOL ALLOWED AFTER DARK" and shall <br />secure the pool area and not permit any use of the pool after dark. (3115B) <br /> #13 Cyanuric Acid Concentration <br />OBSERVATIONS: The pool cyanuric acid level is greater than 100ppm. Take action to reduce the cya level ASAP. <br />REPEAT VIOLATION <br />CALCODE DESCRIPTION: Pool operator shall maintain cyanuric acid concentration between 0.0 ppm and 100 ppm. (CCR 65530) <br />Page 1 of 2EHD 36-01 Rev. 09/16/2020 Swimming Pool OIR <br />FA0007203 PR0506103 SC001 06/22/2023 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD