Environmental Health Department <br />Facility Name and Address: VILLAGE NORTH APARTMENTS, 302 W BENJAMIN HOLT DR, STOCKTON 95207 <br />Swimming Pool Official Inspection Report <br /> #8 Pool and Deck Lighting <br />OBSERVATIONS: Pool light was non operational. Repair/replace pool light so that it is in good working order, within 1 week. <br />(REPEAT) <br />CALCODE DESCRIPTION: Pools used at night shall be equipped with underwater light fixtures that provide complete illumination of the <br />pool. When a pool is used at night, pool deck and emergency egress areas shall be provided with lighting. If underwater or deck lighting is <br />not operational, the pool operator shall post a sign in 4-inch letters stating "NO USE OF POOL ALLOWED AFTER DARK" and shall <br />secure the pool area and not permit any use of the pool after dark. (3115B) <br /> #9 Ladders and Handrails <br />OBSERVATIONS: One handrail at the deep end was observed loose. Tighten handrail within one week. (REPEAT) <br />CALCODE DESCRIPTION: A means of entry and exit shall be provided at both the shallow and deep end of the pool. Ladders and <br />handrails shall be corrosion resistant and shall be rigidly installed. At least one handrail shall extend from the deck to not less than a point <br />above the top of the lowest step. Handrails shall be installed between 28 to 36 inches above the steps and deck. (CBC 3111B) Pool <br />operator shall keep ladders and handrails well maintained. (CCR 65535) <br /> #16 Water Clarity <br />OBSERVATIONS: Pool water was observed cloudy. Maintain pool water clear and clean. Correct Today. <br />CALCODE DESCRIPTION: Pool operator shall maintain clear pool water while pool is in use or shall close the pool if the bottom of the <br />pool at the maximum depth is not clearly visible from the deck. (CCR 65527) <br /> #18 Pool Shell and Tile <br />OBSERVATIONS: Minor pitting was observed in the pool shell. Plan to replaster pool in the future. <br />CALCODE DESCRIPTION: Pool shells shall be white and have a smooth waterproof interior finish that will withstand repeated brushing, <br />and scrubbing. A spa pool may be finished in a light color other than white when approved by the enforcement agency. (CBC 3108B) <br /> #35 Flow Meters <br />OBSERVATIONS: Flow meter was non operational. Repair/replace flow meter within 1 week. (REPEAT) <br />CALCODE DESCRIPTION: Flow meters shall be provided on each recirculation system and shall be installed in accordance with <br />manufacturer's specifications. (CBC 3125B) <br />OVERALL INSPECTION NOTES AND COMMENTS <br />OBSERVATIONS <br />Flow rate:gpm <br />pH: <br />Chlorine:ppm <br />Cyanuric acid:ppm <br />Temp:º F <br />7.6 <br />5.4 <br />50 Combined chlorine:ppm <br />NOTES <br />Influent 9psi <br />Page 2 of 3EHD 36-01 Rev. 09/16/2020 Swimming Pool OIR <br />FA0002119 PR0360486 SC001 06/22/2023 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD