Laserfiche WebLink
Environmental Health Department <br />Time In: <br />11:11 am <br />10:39 am <br />Time Out: <br />Program Element: 3612 - PUBLIC POOL/SPA - ADDITIONAL <br />Telephone: (209) 830-1580 Owner/Operator: WATERSTONE APARTMENTS CA LLC <br />Inspection Type: ROUTINE INSPECTION - Operating Permit <br />Address: 1951 W MIDDLEFIELD DR, TRACY 95377 <br />Date: 06/28/2023Name of Facility: WATERSTONE APARTMENTS CA LLC <br />Swimming Pool Official Inspection Report <br />VIOLATIONS AND CORRECTIVE ACTIONS <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public health <br />and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br /> #11 Combined Chlorine Concentration <br />OBSERVATIONS: The combined chlorine level of the spa water is 1.0ppm. take action to reduce the combined chlorine <br />level to 0.4ppm or less. Correct by 2 weeks. <br />CALCODE DESCRIPTION: Pool operator shall maintain combined chlorine concentration below 0.4 ppm. (CCR 65530) Chemical quality <br />of pool water and indoor air quality at the pool site shall not cause adverse physiological effects, such as irritation of the eyes, lungs, or <br />skin. (CCR 65531) <br /> #18 Pool Shell and Tile <br />OBSERVATIONS: The spa plaster is pitted. Re-plaster the spa by the next routine inspection. <br />CALCODE DESCRIPTION: Pool shells shall be white and have a smooth waterproof interior finish that will withstand repeated brushing, <br />and scrubbing. A spa pool may be finished in a light color other than white when approved by the enforcement agency. (CBC 3108B) <br /> #22 Skimmer Assembly <br />OBSERVATIONS: One of the skimmers lacks a weir door. Properly install weir door by 1 week. <br />One float valve assembly (FVA) at the skimmer has a broken check valve. Replace FVA by 1 week. <br />CALCODE DESCRIPTION: Pool shall be equipped to provide continuous skimming of the pool water. All parts of the skimmer shall be <br />maintained in accordance with manufacturer specifications. (CBC 3136B) <br /> #36 Pressure and Vacuum Gauges <br />OBSERVATIONS: The spa filter lacks an effluent gauge. Properly install an effluent gauge by 1 week. <br />CALCODE DESCRIPTION: Pressure and vacuum gauges shall be provided for each pump system. (CBC 3125B) <br />OVERALL INSPECTION NOTES AND COMMENTS <br />OBSERVATIONS <br />Flow rate:gpm <br />pH: <br />Chlorine:ppm <br />Cyanuric acid:ppm <br />Temp:º F 80 <br />7.4 <br />4.6 <br /><30 <br /> 102.00 <br />Combined chlorine:ppm1.0 <br />Page 1 of 2EHD 36-01 Rev. 09/16/2020 Swimming Pool OIR <br />FA0017844 PR0526368 SC001 06/28/2023 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD