Laserfiche WebLink
Environmental Health Department <br />Time In: <br />11:58 am <br />10:48 am <br />Time Out: <br />Program Element: 3616 - PUBLIC POOL/SPA - EXEMPT <br />Telephone: (209) 825-3200 Owner/Operator: MANTECA UNIFIED SCHOOL DISTRICT <br />Inspection Type: ROUTINE INSPECTION - Operating Permit <br />Address: 1700 N UNION ST, MANTECA 95336 <br />Date: 06/23/2023Name of Facility: MUSD-EAST UNION HIGH SCHOOL <br />Swimming Pool Official Inspection Report <br />VIOLATIONS AND CORRECTIVE ACTIONS <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public health <br />and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br /> #10 Disinfectant Residual MAJOR <br />OBSERVATIONS: Free chlorine is at 0.6 ppm. Provide free chlorine 1 ppm - 10 ppm today. Corrected on site. Free <br />chlorine is at 1 ppm now. <br />CALCODE DESCRIPTION: Public pools, when open or in use, shall be disinfected continuously by approved chemicals and shall maintain <br />the following concentrations: 1.0 ppm to 10.0 ppm free chlorine without cyanuric acid, 2.0 ppm to 10.0 ppm free chlorine with cyanuric acid <br />or 2.0 ppm bromine. Spas, wading pools, and spray grounds shall maintain the following concentrations: 3.0 ppm to 10.0 ppm free <br />chlorine or 4.0 ppm bromine. (CCR 65529) <br /> #8 Pool and Deck Lighting <br />OBSERVATIONS: 3 light fixture bulbs are off. Replace the bulbs in 1 week. <br />CALCODE DESCRIPTION: Pools used at night shall be equipped with underwater light fixtures that provide complete illumination of the <br />pool. When a pool is used at night, pool deck and emergency egress areas shall be provided with lighting. If underwater or deck lighting is <br />not operational, the pool operator shall post a sign in 4-inch letters stating "NO USE OF POOL ALLOWED AFTER DARK" and shall <br />secure the pool area and not permit any use of the pool after dark. (3115B) <br /> #9 Ladders and Handrails <br />OBSERVATIONS: One of the 2 single hand rails is not secured. Secure hand rail today. <br />CALCODE DESCRIPTION: A means of entry and exit shall be provided at both the shallow and deep end of the pool. Ladders and <br />handrails shall be corrosion resistant and shall be rigidly installed. At least one handrail shall extend from the deck to not less than a point <br />above the top of the lowest step. Handrails shall be installed between 28 to 36 inches above the steps and deck. (CBC 3111B) Pool <br />operator shall keep ladders and handrails well maintained. (CCR 65535) <br />OVERALL INSPECTION NOTES AND COMMENTS <br />OBSERVATIONS <br />Flow rate:gpm <br />pH: <br />Chlorine:ppm <br />Cyanuric acid:ppm <br />Temp:º F 700 <br />7.2 <br />0.6 <br />Combined chlorine:ppm <br />NOTES <br />Page 1 of 2EHD 36-01 Rev. 09/16/2020 Swimming Pool OIR <br />FA0000986 PR0360572 SC001 06/23/2023 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD