Laserfiche WebLink
Environmental Health Department <br />Time In: <br />10:45 am <br />10:10 am <br />Time Out: <br />Program Element: 3611 - PUBLIC POOL/SPA - PRIMARY <br />Telephone: Owner/Operator: SCHRUM, ROGER <br />Inspection Type: ROUTINE INSPECTION - Operating Permit <br />Address: 18644 LILAC ST, WOODBRIDGE 95258 <br />Date: 06/29/2023Name of Facility: WOODBRIDGE VILLAGE CONDOMINIUM <br />Swimming Pool Official Inspection Report <br />VIOLATIONS AND CORRECTIVE ACTIONS <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public health <br />and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br /> #2 Pool Enclosure <br />OBSERVATIONS: Observed fence boards near back gate that were loose/deteriorated on the bottom. Repair/replace fence <br />section within 2 weeks. <br />CALCODE DESCRIPTION: Pool area shall be enclosed by one or more of the following: a fence, portion of a building, wall, or other <br />approved durable enclosure. Pool enclosure shall be constructed over a hard permanent material equivalent to concrete and shall be <br />installed no more than 2 inches above the finished grade. Holes, gaps, or openings in the enclosure shall not allow the passage of a <br />4-inch diameter sphere. Doors, openable windows, or gates of living quarters shall not be permitted as part of the pool enclosure. (CBC <br />3119B) Pool operator shall keep the pool enclosure well maintained. (CCR 65535) Pool enclosure shall have a minimum effective <br />perpendicular height of 5 feet and shall be constructed so that it cannot be climbed by small children. Horizontal members shall be spaced <br />at least 48 inches apart. No planters or other climbable structures shall be permitted within 5 feet of the pool enclosure or within a 5-foot <br />arc. Chain link openings shall not be larger than 1 3/4 inches when measured horizontally. Pool enclosures with a height of 4 or more feet <br />are allowed if the enclosure was constructed prior to July 1994. (CBC 3119B) <br /> #4 Safety Equipment <br />OBSERVATIONS: The life ring did not have a throw rope. Provide and attach throw rope to life ring, the rope length must <br />span the maximum width of the pool. Correct today. <br />CALCODE DESCRIPTION: Safety equipment shall be provided, maintained, readily visible, and available for use. Pools shall have at <br />minimum one 12 foot fixed-length rescue pole with a permanently attached body hook and one 17-inch life ring with an attached throw <br />rope. Throw rope shall be of sufficient length to span the maximum width of the pool and shall be stored to prevent kinking or fouling. <br />(CCR 65540) <br /> #13 Cyanuric Acid Concentration <br />OBSERVATIONS: The pool cyanuric acid is greater than 100 ppm. Maintain cyanuric acid between 0-100 ppm when <br />operating. <br />CALCODE DESCRIPTION: Pool operator shall maintain cyanuric acid concentration between 0.0 ppm and 100 ppm. (CCR 65530) <br /> #18 Pool Shell and Tile <br />OBSERVATIONS: Observed some black algae on the pool shell at deep end. Maintain pool shell free of algae and debris. <br />CALCODE DESCRIPTION: Pool shells shall be white and have a smooth waterproof interior finish that will withstand repeated brushing, <br />and scrubbing. A spa pool may be finished in a light color other than white when approved by the enforcement agency. (CBC 3108B) <br />Page 1 of 2EHD 36-01 Rev. 09/16/2020 Swimming Pool OIR <br />FA0003189 PR0360188 SC001 06/29/2023 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD