Environmental Health Department <br />Time In: <br />10:30 am <br /> 9:52 am <br />Time Out: <br />Program Element: 3611 - PUBLIC POOL/SPA - PRIMARY <br />Telephone: Owner/Operator: OAKMONT OF LODI LLC <br />Inspection Type: ROUTINE INSPECTION - Operating Permit <br />Address: 2905 REYNOLDS RANCH PKWY, LODI 95240 <br />Date: 07/03/2023Name of Facility: OAKMONT OF LODI <br />Swimming Pool Official Inspection Report <br />VIOLATIONS AND CORRECTIVE ACTIONS <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public health <br />and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br /> #3 Safety Signs <br />OBSERVATIONS: Pool safety signs were not posted. Provide and post pool capacity, emergency sign, pool facility name <br />and address, CPR sign, no lifeguard, no diving, and “Children under the age of 14 shall not use pool without a parent or <br />adult guardian in attendance.” Correct today. <br />CALCODE DESCRIPTION: Pool operator shall keep safety signs well maintained. (CCR 65535) Safety signs shall have clearly legible <br />letters or numbers not less than 4 inches high, unless otherwise specified. Safety signs shall be affixed to a wall, pole, gate, or similar <br />permanent structure in a location visible to all pool users, unless otherwise specified. (CBC 3120B) <br /> #9 Ladders and Handrails <br />OBSERVATIONS: Handrails were loose. Secure handrails today. <br />CALCODE DESCRIPTION: A means of entry and exit shall be provided at both the shallow and deep end of the pool. Ladders and <br />handrails shall be corrosion resistant and shall be rigidly installed. At least one handrail shall extend from the deck to not less than a point <br />above the top of the lowest step. Handrails shall be installed between 28 to 36 inches above the steps and deck. (CBC 3111B) Pool <br />operator shall keep ladders and handrails well maintained. (CCR 65535) <br /> #22 Skimmer Assembly <br />OBSERVATIONS: Both skimmers were missing o-rings. Provide o-rings today. <br />CALCODE DESCRIPTION: Pool shall be equipped to provide continuous skimming of the pool water. All parts of the skimmer shall be <br />maintained in accordance with manufacturer specifications. (CBC 3136B) <br /> #35 Flow Meters <br />OBSERVATIONS: Flow meter was stuck. Provide working flow meter today. <br />CALCODE DESCRIPTION: Flow meters shall be provided on each recirculation system and shall be installed in accordance with <br />manufacturer's specifications. (CBC 3125B) <br />Page 1 of 2EHD 36-01 Rev. 09/16/2020 Swimming Pool OIR <br />FA0027648 PR0548413 SC001 07/03/2023 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD