ferilization ProceftreS 0 <br />When a body art facility is equipped with a decontamination and sterilization room and will be <br />sterilizing reusable instruments and body art jewelry, the following sterilization procedures must be <br />followed: <br />1. Clean instruments to be sterilized shall first be sealed in peel -packs that contain either a sterilizer <br />indicator or internal temperature indicator. The outside of the pack shall be labeled with the name of <br />the instrument, the date sterilized, and the initials of the person operating the sterilizing equipment. <br />2. Sterilizers shall be loaded, operated, decontaminated and maintained according to manufacturer's <br />directions, and shall meet all of the following standards: <br />• Only equipment manufactured for the sterilization of medical instruments shall be used. <br />• Sterilization equipment shall be tested using a commercial biological indicator monitoring <br />system after the initial installation, after any major repair, and at least once per month. The <br />expiration date of the monitor shall be checked prior to each use. <br />• Each sterilization load shall be monitored with mechanical indicators for time, temperature, <br />pressure, and, at a minimum, Class V integrators. The Class V integrator gives an immediate <br />response on whether the sterilization has been achieved. Each individual sterilization pack <br />shall have an indicator. <br />• Biological indicator monitoring test results shall be recorded in a log that shall be kept on site <br />for two years after the date of the results. <br />• A written log of each sterilization cycle shall be retained on site for two -years and shall include <br />all of the following information: <br />(a) The date of the load. <br />(b) A list of the contents of the load. <br />(c) The exposure time and temperature. <br />(d) The results of the Class V integrator. <br />(e) For cycles where the results of the biological indicator monitoring test are positive, how <br />the items were cleaned, and proof of a negative test before reuse. <br />3. Clean instruments and sterilized instrument packs shall be placed in clean, dry, labeled <br />containers, or stored in a labeled cabinet that is protected from dust and moisture. Use clean gloves <br />to handle sterilized packages to prevent cross contamination of the sterilized item when the package <br />is opened for use. <br />4. Sterilized instruments shall be stored in the intact peel -packs or in the sterilization equipment <br />cartridge until time of use. <br />5. Sterile instrument packs shall be evaluated at the time of storage and before use. If the integrity of <br />a pack is compromised, including, but not limited to, cases where the pack is torn, punctured, wet, or <br />displaying any evidence of moisture contamination, the pack shall be discarded or reprocessed <br />before use. <br />Page 7 of 9 <br />