My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2023
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
D
>
DR MARTIN LUTHER KING JR
>
1233
>
2200 - Hazardous Waste Program
>
PR0547068
>
COMPLIANCE INFO_2023
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/14/2024 9:53:57 AM
Creation date
7/19/2023 2:45:14 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
2023
RECORD_ID
PR0547068
PE
2220
FACILITY_ID
FA0026688
FACILITY_NAME
7-ELEVEN INC. #41342
STREET_NUMBER
1233
Direction
E
STREET_NAME
DR MARTIN LUTHER KING JR
STREET_TYPE
BLVD
City
STOCKTON
Zip
95205
CURRENT_STATUS
01
SITE_LOCATION
1233 E DR MARTIN LUTHER KING JR BLVD
QC Status
Approved
Scanner
SJGOV\lsauers1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
9
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN J OAQU I N Environmental Health Department <br /> CCLJNTY <br /> Small Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address: Date: <br /> 7-ELEVEN INC.#41342 1 1233 E DR MARTIN LUTHER KING JR BLVD, July 17, 2023 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 104 CCR 66262.34(d)(2)No modified contingency plan. <br /> OBSERVATION: Modified contingency plan information was not posted at the facility. <br /> REGULATION GUIDANCE: The business operator must post the following information next to telephones or in <br /> areas directly involved in the generation and accumulation of hazardous waste: the name and emergency <br /> telephone number of the emergency coordinator, the location of fire extinguishers and spill control material, and the <br /> telephone number of the fire department unless the facility has a direct alarm. <br /> CORRECTIVE ACTION: Immediately post the modified contingency plan information or keep a copy of a complete <br /> consolidated emergency response/contingency plan on-site. Provide a statement to the San Joaquin County <br /> Environmental Health Department that the correction is complete. <br /> This is a minor violation. <br /> 302 CCR 66262.34(d)(2) Failed to have all communication or alarm systems, spill control, or decontamination <br /> equipment. <br /> OBSERVATION: The facility is not equipped with the following equipment: <br /> -Multiple fire extinguishers were listed in the emergency plan, but only one was observed. None were observed <br /> near the hazardous waste areas. <br /> -Spill kit was not observed.According to manager Sara Belasco, no spill kit or absorbent is on site. <br /> REGULATION GUIDANCE: <br /> All facilities shall be equipped with the following, unless it can be demonstrated to the Department that none of the <br /> hazards posed by waste handled at the facility could require a particular kind of equipment specified below: <br /> (a)an internal communications or alarm system capable of providing immediate emergency instruction (voice or <br /> signal)to facility personnel; <br /> (b)a device, such as a telephone (immediately available at the scene of operations)or a hand-held two-way radio, <br /> capable of summoning emergency assistance from local police departments,fire departments, or State or local <br /> emergency response teams; <br /> (c)portable fire extinguishers,fire control equipment(including special extinguishing equipment, such as that using <br /> foam, inert gas, or dry chemicals), spill control equipment, and decontamination equipment; and <br /> (d)water at adequate volume and pressure to supply water hose streams, or foam producing equipment, or <br /> automatic sprinklers, or water spray systems . <br /> CORRECTIVE ACTION: Immediately install the following equipment:fire extinguishers and spill control equipment. <br /> Provide a corrective action statement and supporting documentation to the San Joaquin County Environmental <br /> Health Department within 30 days. <br /> This is a Class II violation. <br /> FA0026688 PR0547068 SCO01 07/17/2023 <br /> EHD 22-01 Rev.12/06/2021 Page 4 of 6 Small Quantity Hazardous Waste Generator OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />
The URL can be used to link to this page
Your browser does not support the video tag.