Environmental Health Department <br />Facility Name and Address: DON AVENUE APARTMENTS, 8534 DON AVE, STOCKTON 95209 <br />Swimming Pool Official Inspection Report <br /> #3 Safety Signs <br />OBSERVATIONS: Lacking max pool capacity on sign. Provide max pool capacity today. <br />Lacking Keep Closed sign on east gate. Provide sign if gate will be used. <br />CALCODE DESCRIPTION: Pool operator shall keep safety signs well maintained. (CCR 65535) Safety signs shall have clearly legible <br />letters or numbers not less than 4 inches high, unless otherwise specified. Safety signs shall be affixed to a wall, pole, gate, or similar <br />permanent structure in a location visible to all pool users, unless otherwise specified. (CBC 3120B) <br /> #4 Safety Equipment <br />OBSERVATIONS: The rescue pole was deteriorated and the fiberglass was exposed, per property manager tye <br />CALCODE DESCRIPTION: Safety equipment shall be provided, maintained, readily visible, and available for use. Pools shall have at <br />minimum one 12 foot fixed-length rescue pole with a permanently attached body hook and one 17-inch life ring with an attached throw <br />rope. Throw rope shall be of sufficient length to span the maximum width of the pool and shall be stored to prevent kinking or fouling. <br />(CCR 65540) <br /> #5 Restrooms and Showers <br />OBSERVATIONS: The hot water at the shower was 112 F. Provide hot and cold water with hot water not exceeding 110 F <br />today. <br />CALCODE DESCRIPTION: Pool operator shall ensure the following facilities are maintained and kept clean: showers, toilets, dressing <br />facilities, drinking fountains, diaper-changing stations, floors, walls, partitions, doors, and lockers. Showers (except outside) shall be <br />provided with soap in dispensers. Toilet facilities shall be provided with toilet tissue, hand soap, and paper towels or hot air blowers in <br />permanently installed dispensers. Pool operator shall provide a minimum of one waste receptacle in each toilet facility. Wooden slats, <br />duckboards and footbaths are prohibited. ( CCR 65535, 65551) Showers and lavatories shall be provided with hot and cold water faucets. <br />Maximum water temperature at showers and lavatories shall not exceed 110*F. (CBC 3116B) <br /> #7 Pool Deck <br />OBSERVATIONS: Observed hole/gap between west skimmer and pool deck. Seal and provide smooth surface within 1 <br />week. <br />CALCODE DESCRIPTION: An unobstructed 4-foot wide deck of concrete or like material shall be provided and maintained flush with the <br />top of the pool coping. Deck shall extend completely around the pool and shall further extend 4 feet on both sides and to the rear of any <br />diving board, ADA device, or slide. (CBC 3114B) Pool operator shall keep the pool deck well maintained. (CCR 65535) <br /> #18 Pool Shell and Tile <br />OBSERVATIONS: Observed chipping on bottom of pool shell. Provide smooth pool shell. <br />CALCODE DESCRIPTION: Pool shells shall be white and have a smooth waterproof interior finish that will withstand repeated brushing, <br />and scrubbing. A spa pool may be finished in a light color other than white when approved by the enforcement agency. (CBC 3108B) <br />Page 2 of 3EHD 36-01 Rev. 09/16/2020 Swimming Pool OIR <br />FA0002842 PR0360608 SC001 07/10/2023 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD