Laserfiche WebLink
Environmental Health Department <br />Time In: <br />11:20 am <br />10:54 am <br />Time Out: <br />Program Element: 3612 - PUBLIC POOL/SPA - ADDITIONAL <br />Telephone: Owner/Operator: DUKE, CHRIS <br />Inspection Type: ROUTINE INSPECTION - Operating Permit <br />Address: 2890 S STOCKTON ST, LODI 95240 <br />Date: 07/19/2023Name of Facility: LA VIDA AT REYNOLDS RANCH <br />Swimming Pool Official Inspection Report <br />VIOLATIONS AND CORRECTIVE ACTIONS <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public health <br />and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br /> #7 Pool Deck <br />OBSERVATIONS: Observed crack/hole in pool deck near east handrail. Seal/repair. Corrected on site, hole was sealed <br />with silicone. <br />CALCODE DESCRIPTION: An unobstructed 4-foot wide deck of concrete or like material shall be provided and maintained flush with the <br />top of the pool coping. Deck shall extend completely around the pool and shall further extend 4 feet on both sides and to the rear of any <br />diving board, ADA device, or slide. (CBC 3114B) Pool operator shall keep the pool deck well maintained. (CCR 65535) <br /> #9 Ladders and Handrails <br />OBSERVATIONS: The west handrails were loose. Secure handrails. Corrected on site. <br />CALCODE DESCRIPTION: A means of entry and exit shall be provided at both the shallow and deep end of the pool. Ladders and <br />handrails shall be corrosion resistant and shall be rigidly installed. At least one handrail shall extend from the deck to not less than a point <br />above the top of the lowest step. Handrails shall be installed between 28 to 36 inches above the steps and deck. (CBC 3111B) Pool <br />operator shall keep ladders and handrails well maintained. (CCR 65535) <br /> #32 Chemical Control and Monitoring System <br />OBSERVATIONS: The chemical monitoring system was not being used, per pool tech it does not work. Provide and use <br />working chemical monitoring system. Correct within 1 month. <br />CALCODE DESCRIPTION: Chemical feeders shall be constructed with an adjustable output rate device controlled by an approved <br />automatic chemical monitoring and control system that regulates at minimum pH and disinfectant. Chemical feeders shall be constructed <br />and installed to prevent uncontrolled discharge or siphoning of chemicals and fumes directly into the pool, recirculation system, pool area, <br />or ancillary facilities. (CBC 3133B) <br /> #35 Flow Meters <br />OBSERVATIONS: The flow meter was not working. Provide working flow meter today. <br />CALCODE DESCRIPTION: Flow meters shall be provided on each recirculation system and shall be installed in accordance with <br />manufacturer's specifications. (CBC 3125B) <br />Page 1 of 2EHD 36-01 Rev. 09/16/2020 Swimming Pool OIR <br />FA0026226 PR0546304 SC001 07/19/2023 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD