Laserfiche WebLink
Environmental Health Department <br />Time In: <br />10:54 am <br />10:24 am <br />Time Out: <br />Program Element: 3611 - PUBLIC POOL/SPA - PRIMARY <br />Telephone: Owner/Operator: DUKE, CHRIS <br />Inspection Type: ROUTINE INSPECTION - Operating Permit <br />Address: 2890 S STOCKTON ST, LODI 95240 <br />Date: 07/19/2023Name of Facility: LA VIDA AT REYNOLDS RANCH <br />Swimming Pool Official Inspection Report <br />VIOLATIONS AND CORRECTIVE ACTIONS <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public health <br />and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br /> #9 Ladders and Handrails <br />OBSERVATIONS: Handrail on south side was loose. Secure handrail. Corrected on site. <br />CALCODE DESCRIPTION: A means of entry and exit shall be provided at both the shallow and deep end of the pool. Ladders and <br />handrails shall be corrosion resistant and shall be rigidly installed. At least one handrail shall extend from the deck to not less than a point <br />above the top of the lowest step. Handrails shall be installed between 28 to 36 inches above the steps and deck. (CBC 3111B) Pool <br />operator shall keep ladders and handrails well maintained. (CCR 65535) <br /> #32 Chemical Control and Monitoring System <br />OBSERVATIONS: The chemical monitoring system was not being used, per pool tech it does not work. Provide and use <br />working chemical monitoring system. Correct within 1 month. <br />CALCODE DESCRIPTION: Chemical feeders shall be constructed with an adjustable output rate device controlled by an approved <br />automatic chemical monitoring and control system that regulates at minimum pH and disinfectant. Chemical feeders shall be constructed <br />and installed to prevent uncontrolled discharge or siphoning of chemicals and fumes directly into the pool, recirculation system, pool area, <br />or ancillary facilities. (CBC 3133B) <br /> #35 Flow Meters <br />OBSERVATIONS: The flow meter was not working. Provide working flow meter today. <br />CALCODE DESCRIPTION: Flow meters shall be provided on each recirculation system and shall be installed in accordance with <br />manufacturer's specifications. (CBC 3125B) <br />OVERALL INSPECTION NOTES AND COMMENTS <br />OBSERVATIONS <br />Flow rate:gpm <br />pH: <br />Chlorine:ppm <br />Cyanuric acid:ppm <br />Temp:º F <br />7.6 <br />3.8 <br /><30 Combined chlorine:ppm <br />NOTES <br />Influent: 17 PSI, 18 PSI <br />Effluent: 11 PSI, 20 PSI <br />Pool lights, safety equipment, shower, and restrooms ok. <br />Page 1 of 2EHD 36-01 Rev. 09/16/2020 Swimming Pool OIR <br />FA0026226 PR0546303 SC001 07/19/2023 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD