Laserfiche WebLink
Document management portal powered by Laserfiche WebLink 9 © 1998-2015 Laserfiche. All rights reserved.
SAN J 0 A Q U I N Environmental Health Department <br /> CC)U NTY <br /> Swimming Pool Official Inspection Report <br /> Facility Name and Address: FLAG CITY RV RESORT, 6120 W BANNER ST, LODI 95242 <br /> #15 Operation Records <br /> OBSERVATIONS:Spa testing logs were not maintained. Maintain testing logs for daily chlorine, pH, and water temp and <br /> monthly cyanuric acid testing. <br /> CALCODE DESCRIPTION:Pool operator shall test the disinfectant residual,pH, and spa water temperature a minimum of once per day. <br /> Cyanuric acid concentration shall be tested once per month if cyanuric acid is used. Combined chlorine shall be tested as often as <br /> necessary to maintain the concentration below 0.4 ppm. Pool operator shall maintain written records of all maintenance and test results <br /> for at least two years and shall submit those records to the enforcement agency upon request. (CCR 65523) <br /> #18 Pool Shell and Tile <br /> OBSERVATIONS:Observed chipping on spa shell. Provide smooth spa shell. <br /> CALCODE DESCRIPTION:Pool shells shall be white and have a smooth waterproof interior finish that will withstand repeated brushing, <br /> and scrubbing.A spa pool may be finished in a light color other than white when approved by the enforcement agency. (CBC 3108B) <br /> #30 Pool Equipment and Plumbing Maintained <br /> OBSERVATIONS:Observed leaking from bottom pipe near heating unit. Repair leak today. <br /> CALCODE DESCRIPTION:All equipment related to pool operations shall be installed and maintained in accordance with manufacturer's <br /> specifications and shall comply with applicable requirements established by applicable NSF/ANSI-50 performance standards. (CBC <br /> 3123B) <br /> #38 Filter Cleaning and Maintenance <br /> OBSERVATIONS:The influent and effluent pressure difference was greater than 10 PSI. Recommend <br /> clean ing/backwashing filter. <br /> CALCODE DESCRIPTION:All filters shall be maintained in accordance with manufacturer's specifications. (CBC 3123B)Pressure gauge <br /> located on the filter shall be marked with the clean startup reading. (CBC 3125B)Each filter vessel shall be provided with valves so that it <br /> can be isolated from the recirculation system for repairs and backwashing. (CBC 3128B) <br /> OVERALL INSPECTION NOTES AND COMMENTS <br /> OBSERVATIONS <br /> Flow rate: 65 gpm Chlorine: >14 ppm Temp: 100.00 ° F <br /> Cyanuric acid: >100 ppm pH: 7.6 Combined chlorine: ppm <br /> NOTES <br /> Influent: 21 PSI <br /> Effluent: 10 PSI <br /> Keep spa closed until chlorine correction is verified by EHD. <br /> FA0016673 PR0524855 SCO01 07/17/2023 <br /> EHD 36-01 Rev.09/16/2020 Page 2 of 3 Swimming Pool OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />