Laserfiche WebLink
Environmental Health Department <br />Time In: <br />10:00 am <br /> 9:25 am <br />Time Out: <br />Program Element: 3611 - PUBLIC POOL/SPA - PRIMARY <br />Telephone: (209) 951-4391 Owner/Operator: PATMON COMPANY INC <br />Inspection Type: ROUTINE INSPECTION - Operating Permit <br />Address: 1619 E BRIDLE PATH PL, STOCKTON 95210 <br />Date: 07/19/2023Name of Facility: BRIDLE PATH APTS <br />Swimming Pool Official Inspection Report <br />VIOLATIONS AND CORRECTIVE ACTIONS <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public health <br />and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br /> #10 Disinfectant Residual MAJOR <br />OBSERVATIONS: Free residual chlorine level was 21 ppm. Maintain free residual chlorine level between 2 ppm and 10 <br />ppm. Corrected on site. Pool service tech reduced the free residual chlorine level to 9.6 ppm. <br />CALCODE DESCRIPTION: Public pools, when open or in use, shall be disinfected continuously by approved chemicals and shall maintain <br />the following concentrations: 1.0 ppm to 10.0 ppm free chlorine without cyanuric acid, 2.0 ppm to 10.0 ppm free chlorine with cyanuric acid <br />or 2.0 ppm bromine. Spas, wading pools, and spray grounds shall maintain the following concentrations: 3.0 ppm to 10.0 ppm free <br />chlorine or 4.0 ppm bromine. (CCR 65529) <br /> #7 Pool Deck <br />OBSERVATIONS: Gaps between concrete pads on deep of pool deck. Seal gaps within 2 weeks. <br />CALCODE DESCRIPTION: An unobstructed 4-foot wide deck of concrete or like material shall be provided and maintained flush with the <br />top of the pool coping. Deck shall extend completely around the pool and shall further extend 4 feet on both sides and to the rear of any <br />diving board, ADA device, or slide. (CBC 3114B) Pool operator shall keep the pool deck well maintained. (CCR 65535) <br /> #9 Ladders and Handrails <br />OBSERVATIONS: Observed damaged bolt covers on ladder hand rails. Repair/replace covers within 2 weeks. <br />CALCODE DESCRIPTION: A means of entry and exit shall be provided at both the shallow and deep end of the pool. Ladders and <br />handrails shall be corrosion resistant and shall be rigidly installed. At least one handrail shall extend from the deck to not less than a point <br />above the top of the lowest step. Handrails shall be installed between 28 to 36 inches above the steps and deck. (CBC 3111B) Pool <br />operator shall keep ladders and handrails well maintained. (CCR 65535) <br /> #18 Pool Shell and Tile <br />OBSERVATIONS: Observed horizontal cracks in concrete above pool water line tiles throughout pool. Repair by next year. <br />CALCODE DESCRIPTION: Pool shells shall be white and have a smooth waterproof interior finish that will withstand repeated brushing, <br />and scrubbing. A spa pool may be finished in a light color other than white when approved by the enforcement agency. (CBC 3108B) <br />Page 1 of 2EHD 36-01 Rev. 09/16/2020 Swimming Pool OIR <br />FA0001714 PR0360614 SC001 07/19/2023 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD