Laserfiche WebLink
Environmental Health Department <br />Time In: <br />10:18 am <br /> 9:48 am <br />Time Out: <br />Program Element: 3612 - PUBLIC POOL/SPA - ADDITIONAL <br />Telephone: (209) 952-9400 Owner/Operator: STONEWOOD ESTATES HOA <br />Inspection Type: ROUTINE INSPECTION - Operating Permit <br />Address: 2727 SUMMER FIELD DR, STOCKTON 95209 <br />Date: 07/18/2023Name of Facility: STONEWOOD ESTATES HOA <br />Swimming Pool Official Inspection Report <br />VIOLATIONS AND CORRECTIVE ACTIONS <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public health <br />and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br /> #37 Electrical Hazards MAJOR <br />OBSERVATIONS: The GFCI for pool light was tripped at the breaker panel and would not reset. Provide functional GFCI for <br />pool light. Keep pool closed until correction is verified by EHD. <br />CALCODE DESCRIPTION: Electrical equipment installed in the water, walls, deck, or equipment room of a public pool shall comply with <br />California Electrical Code. (CEC 680.4) Light fixtures installed in the pool that operate at more than 15 volts shall be protected by a ground <br />fault circuit interrupter. (CBC 3160B) <br /> #7 Pool Deck <br />OBSERVATIONS: Observed gaps/cracks between pool deck and coping. Repair/seal within 2 weeks. <br />CALCODE DESCRIPTION: An unobstructed 4-foot wide deck of concrete or like material shall be provided and maintained flush with the <br />top of the pool coping. Deck shall extend completely around the pool and shall further extend 4 feet on both sides and to the rear of any <br />diving board, ADA device, or slide. (CBC 3114B) Pool operator shall keep the pool deck well maintained. (CCR 65535) <br /> #22 Skimmer Assembly <br />OBSERVATIONS: Skimmer was lacking weir. Provide weir. Corrected on site. <br />CALCODE DESCRIPTION: Pool shall be equipped to provide continuous skimming of the pool water. All parts of the skimmer shall be <br />maintained in accordance with manufacturer specifications. (CBC 3136B) <br /> #35 Flow Meters <br />OBSERVATIONS: Lacking flow meter. Provide flow meter today and email evidence of correction to dafonskaia@sjgov.org <br />CALCODE DESCRIPTION: Flow meters shall be provided on each recirculation system and shall be installed in accordance with <br />manufacturer's specifications. (CBC 3125B) <br />Page 1 of 2EHD 36-01 Rev. 09/16/2020 Swimming Pool OIR <br />FA0002066 PR0360528 SC001 07/18/2023 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD