Environmental Health Department <br />Facility Name and Address: PACIFIC VILLAS LP, 4550 SHELLEY CT, STOCKTON 95207 <br />Swimming Pool Official Inspection Report <br /> #3 Safety Signs <br />OBSERVATIONS: Safety signs are missing site location information, nearest hospital information, and pool capacity. <br />Provide information on safety sign today. <br />CALCODE DESCRIPTION: Pool operator shall keep safety signs well maintained. (CCR 65535) Safety signs shall have clearly legible <br />letters or numbers not less than 4 inches high, unless otherwise specified. Safety signs shall be affixed to a wall, pole, gate, or similar <br />permanent structure in a location visible to all pool users, unless otherwise specified. (CBC 3120B) <br /> #17 Cleanliness of Pool <br />OBSERVATIONS: Debris and algae growth accumulation on pool bottom. Clean and maintain free of debris and algae <br />growth today. <br />CALCODE DESCRIPTION: Pool operator shall maintain clean pool water while the pool is in use and shall not allow debris to accumulate <br />in the pool. Pool operator shall clean the bottom, sides, and other surfaces of the pool as often as necessary to keep pool surfaces clean <br />and free of slime and algae. (CCR 65533) <br /> #22 Skimmer Assembly <br />OBSERVATIONS: Both skimmers are missing float assembly and weir doors. Provide float assembly and weir door within 1 <br />week. <br />CALCODE DESCRIPTION: Pool shall be equipped to provide continuous skimming of the pool water. All parts of the skimmer shall be <br />maintained in accordance with manufacturer specifications. (CBC 3136B) <br /> #27 Pool Equipment Room <br />OBSERVATIONS: Pool equipment door is lacking. Observed piece of wood being drilled in place to serve as a door to pool <br />equipment room. Provide functional door for equipment room and maintain facilities well maintained. <br />CALCODE DESCRIPTION: Pool operator shall keep ancillary facilities well maintained. (CCR 65535) All filters, valves, pumps, strainers <br />and equipment shall be readily accessible for repair and replacement. (CBC 3123B) <br /> #35 Flow Meters <br />OBSERVATIONS: Flow meter is not operational. Provide operational flow meter today. <br />CALCODE DESCRIPTION: Flow meters shall be provided on each recirculation system and shall be installed in accordance with <br />manufacturer's specifications. (CBC 3125B) <br /> #36 Pressure and Vacuum Gauges <br />OBSERVATIONS: Effluent gauge is not operational. Repair/replace effluent gauge today. <br />CALCODE DESCRIPTION: Pressure and vacuum gauges shall be provided for each pump system. (CBC 3125B) <br />Page 2 of 3EHD 36-01 Rev. 09/16/2020 Swimming Pool OIR <br />FA0002507 PR0360408 SC001 07/25/2023 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD