Laserfiche WebLink
Environmental Health Department <br />Time In: <br />12:40 pm <br />12:10 pm <br />Time Out: <br />Program Element: 3612 - PUBLIC POOL/SPA - ADDITIONAL <br />Telephone: (209) 957-5707 Owner/Operator: BRE MG WATERFIELD SQUARE LLC <br />Inspection Type: ROUTINE INSPECTION - Operating Permit <br />Address: 8035 MARINERS DR, STOCKTON 95219 <br />Date: 07/18/2023Name of Facility: WATERFIELD SQUARE APARTMENTS <br />Swimming Pool Official Inspection Report <br />VIOLATIONS AND CORRECTIVE ACTIONS <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public health <br />and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br /> #10 Disinfectant Residual MAJOR <br />OBSERVATIONS: The chlorine at the spa was 2.6 ppm. Maintain chlorine between 3-10 ppm when operating. Corrected on <br />site, chlorine was added and it was 9.2 ppm. <br />CALCODE DESCRIPTION: Public pools, when open or in use, shall be disinfected continuously by approved chemicals and shall maintain <br />the following concentrations: 1.0 ppm to 10.0 ppm free chlorine without cyanuric acid, 2.0 ppm to 10.0 ppm free chlorine with cyanuric acid <br />or 2.0 ppm bromine. Spas, wading pools, and spray grounds shall maintain the following concentrations: 3.0 ppm to 10.0 ppm free <br />chlorine or 4.0 ppm bromine. (CCR 65529) <br /> #18 Pool Shell and Tile <br />OBSERVATIONS: Observed some chipping on pool shell. Provide smooth pool shell. <br />CALCODE DESCRIPTION: Pool shells shall be white and have a smooth waterproof interior finish that will withstand repeated brushing, <br />and scrubbing. A spa pool may be finished in a light color other than white when approved by the enforcement agency. (CBC 3108B) <br /> #22 Skimmer Assembly <br />OBSERVATIONS: The float valve assembly was broken and the bottom was stuck. Remove and replace float valve <br />assembly today. <br />CALCODE DESCRIPTION: Pool shall be equipped to provide continuous skimming of the pool water. All parts of the skimmer shall be <br />maintained in accordance with manufacturer specifications. (CBC 3136B) <br /> #30 Pool Equipment and Plumbing Maintained <br />OBSERVATIONS: Observed leaking from top of spa filter. Repair leak today. <br />CALCODE DESCRIPTION: All equipment related to pool operations shall be installed and maintained in accordance with manufacturer's <br />specifications and shall comply with applicable requirements established by applicable NSF/ANSI-50 performance standards. (CBC <br />3123B) <br />Page 1 of 2EHD 36-01 Rev. 09/16/2020 Swimming Pool OIR <br />FA0002741 PR0360285 SC001 07/18/2023 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD