Laserfiche WebLink
Environmental Health Department <br />Time In: <br />10:45 am <br />10:25 am <br />Time Out: <br />Program Element: 3612 - PUBLIC POOL/SPA - ADDITIONAL <br />Telephone: (714) 852-5575 Owner/Operator: NEWPORT PACIFIC CAPITAL CO <br />Inspection Type: ROUTINE INSPECTION - Operating Permit <br />Address: 19690 N HWY 99 , ACAMPO 95220 <br />Date: 07/25/2023Name of Facility: ARBOR MOBILE HOME PARK <br />Swimming Pool Official Inspection Report <br />VIOLATIONS AND CORRECTIVE ACTIONS <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public health <br />and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br /> #10 Disinfectant Residual MAJOR <br />OBSERVATIONS: Free residual chlorine level was 1.8 ppm. Maintain free residual chlorine levels between 3.0 ppm and <br />10.0 ppm. Corrected on site by management. Free residual chlorine was raised to 9.8 ppm. <br />CALCODE DESCRIPTION: Public pools, when open or in use, shall be disinfected continuously by approved chemicals and shall maintain <br />the following concentrations: 1.0 ppm to 10.0 ppm free chlorine without cyanuric acid, 2.0 ppm to 10.0 ppm free chlorine with cyanuric acid <br />or 2.0 ppm bromine. Spas, wading pools, and spray grounds shall maintain the following concentrations: 3.0 ppm to 10.0 ppm free <br />chlorine or 4.0 ppm bromine. (CCR 65529) <br /> #22 Skimmer Assembly <br />OBSERVATIONS: The skimmer is lacking an O-ring. Provide O-ring within 1 week. <br />CALCODE DESCRIPTION: Pool shall be equipped to provide continuous skimming of the pool water. All parts of the skimmer shall be <br />maintained in accordance with manufacturer specifications. (CBC 3136B) <br /> #35 Flow Meters <br />OBSERVATIONS: Flow meter is not operational. Repair/replace flow meter today. <br />CALCODE DESCRIPTION: Flow meters shall be provided on each recirculation system and shall be installed in accordance with <br />manufacturer's specifications. (CBC 3125B) <br /> #38 Filter Cleaning and Maintenance <br />OBSERVATIONS: Pressure difference between influent and effluent gauge is greater than 10 PSI. Clean/backwash filter. <br />CALCODE DESCRIPTION: All filters shall be maintained in accordance with manufacturer's specifications. (CBC 3123B) Pressure gauge <br />located on the filter shall be marked with the clean startup reading. (CBC 3125B) Each filter vessel shall be provided with valves so that it <br />can be isolated from the recirculation system for repairs and backwashing. (CBC 3128B) <br />OVERALL INSPECTION NOTES AND COMMENTS <br />OBSERVATIONS <br />Flow rate:gpm <br />pH: <br />Chlorine:ppm <br />Cyanuric acid:ppm <br />Temp:º F <br />7.2 <br />1.8 <br />30 <br /> 100.00 <br />Combined chlorine:ppm <br />Page 1 of 2EHD 36-01 Rev. 09/16/2020 Swimming Pool OIR <br />FA0018660 PR0360191 SC001 07/25/2023 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD