COMPLIANCE INFO_2023
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
NEPLUS
>
321
>
3600 - Recreational Health Program
>
PR0360090
>
COMPLIANCE INFO_2023
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/2/2023 4:06:58 PM
Creation date
8/2/2023 4:06:42 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3600 - Recreational Health Program
File Section
COMPLIANCE INFO
FileName_PostFix
2023
RECORD_ID
PR0360090
PE
3611
FACILITY_ID
FA0000950
FACILITY_NAME
NEPLUS APARTMENTS
STREET_NUMBER
321
STREET_NAME
NEPLUS
STREET_TYPE
CT
City
LODI
Zip
95242
APN
03533001
CURRENT_STATUS
01
SITE_LOCATION
321 NEPLUS CT
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
2
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Environmental Health Department <br />Facility Name and Address: NEPLUS APARTMENTS, 321 NEPLUS CT, LODI 95242 <br />Swimming Pool Official Inspection Report <br /> #29 Recirculation System Operation <br />OBSERVATIONS: Recirculation pump was turned off. Corrected on site by manager. Maintain recirculation pump turned on <br />during hours of operation. <br />CALCODE DESCRIPTION: Recirculation system shall be in operation whenever the pool is available for use and additional times as <br />needed to maintain clear pool water. (CCR 65525) <br /> #35 Flow Meters <br />OBSERVATIONS: Flow meter is not operational. Repair/replace flow meter today. <br />CALCODE DESCRIPTION: Flow meters shall be provided on each recirculation system and shall be installed in accordance with <br />manufacturer's specifications. (CBC 3125B) <br /> #39 Wastewater Disposal <br />OBSERVATIONS: Observed line for backwashing filter leads into yard next to filter. Discontinue this practice and connect <br />backwashing line to sewer line. Correct today. <br />CALCODE DESCRIPTION: Backwash from sand filters shall discharge indirectly into a sump with sufficient capacity to receive <br />wastewater without overflowing. Backwash from diatomaceous earth filters shall discharge into a separation tank designed to collect the <br />diatomaceous earth mixture. Wastewater from the separation tank shall discharge into the sanitary sewer. A visible sight indicator shall <br />be installed on the backwash line when discharge is not visible to the pool operator. Pool recirculation system shall not be directly <br />connected to the sanitary sewer system. (CBC 3141B) Cartridge filters shall be cleaned in an approved wash down area equipped with <br />potable water supply. Wash down area shall discharge through permanently installed plumbing into the sanitary sewer. (CBC 3132B) <br />OVERALL INSPECTION NOTES AND COMMENTS <br />OBSERVATIONS <br />Flow rate:gpm <br />pH: <br />Chlorine:ppm <br />Cyanuric acid:ppm <br />Temp:º F <br />7.4 <br />0.0 <br />40 Combined chlorine:ppm <br />NOTES <br />Routine inspection. <br />Influent: 9 PSI <br />Effluent: 1 PSI <br />The person in charge is responsible for ensuring that the above mentioned facility is in compliance with all applicable sections of the California Health and <br />Safety Code. If a reinspection is required, fees will be assessed at the current hourly rate. <br />Received by: Name and Title: <br />EH Specialist:Phone:(209) 616-3032 <br />, <br />FRANCISCO RUIZ <br />Page 2 of 2EHD 36-01 Rev. 09/16/2020 Swimming Pool OIR <br />FA0000950 PR0360090 SC001 07/27/2023 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD