Laserfiche WebLink
Environmental Health Department <br />Time In: <br />10:50 am <br />10:27 am <br />Time Out: <br />Program Element: 3611 - PUBLIC POOL/SPA - PRIMARY <br />Telephone: Owner/Operator: STOCKTON HOTEL GROUP LLC <br />Inspection Type: INSPECTION/REINSPECTION (Chargeable) <br />Address: 1625 E FRENCH CAMP TPKE, STOCKTON 95206 <br />Date: 08/09/2023Name of Facility: ECONO LODGE <br />Swimming Pool Official Inspection Report <br />VIOLATIONS AND CORRECTIVE ACTIONS <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public health <br />and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br /> #4 Safety Equipment <br />OBSERVATIONS: The life hook was detached from the pole. Ensure safety equipment is maintained in proper working <br />order and available for use at all times. Provide proof of correction to cmuro@sjgov.org. <br />CALCODE DESCRIPTION: Safety equipment shall be provided, maintained, readily visible, and available for use. Pools shall have at <br />minimum one 12 foot fixed-length rescue pole with a permanently attached body hook and one 17-inch life ring with an attached throw <br />rope. Throw rope shall be of sufficient length to span the maximum width of the pool and shall be stored to prevent kinking or fouling. <br />(CCR 65540) <br /> #9 Ladders and Handrails <br />OBSERVATIONS: Both handrails were observed loose. Pool maintenance tech provided documentation that the required <br />tools for repair of rails have been ordered. <br />CALCODE DESCRIPTION: A means of entry and exit shall be provided at both the shallow and deep end of the pool. Ladders and <br />handrails shall be corrosion resistant and shall be rigidly installed. At least one handrail shall extend from the deck to not less than a point <br />above the top of the lowest step. Handrails shall be installed between 28 to 36 inches above the steps and deck. (CBC 3111B) Pool <br />operator shall keep ladders and handrails well maintained. (CCR 65535) <br /> #35 Flow Meters <br />OBSERVATIONS: Flow meter is still in disrepair. Pool maintenance tech provided documentation that the flow meter has <br />been ordered. <br />CALCODE DESCRIPTION: Flow meters shall be provided on each recirculation system and shall be installed in accordance with <br />manufacturer's specifications. (CBC 3125B) <br /> #36 Pressure and Vacuum Gauges <br />OBSERVATIONS: The filtration system currently lacks an effluent gauge at this time. Obtain and maintain to ensure proper <br />effluent pressure is maintained. Correct before the next routine inspection. <br />CALCODE DESCRIPTION: Pressure and vacuum gauges shall be provided for each pump system. (CBC 3125B) <br />Page 1 of 2EHD 36-01 Rev. 09/16/2020 Swimming Pool OIR <br />FA0001722 PR0360086 SC333 08/09/2023 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD