My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2023
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1700
>
2300 - Underground Storage Tank Program
>
PR0231454
>
COMPLIANCE INFO_2023
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/18/2023 6:57:02 PM
Creation date
8/9/2023 2:26:02 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2023
RECORD_ID
PR0231454
PE
2361
FACILITY_ID
FA0003796
FACILITY_NAME
Manteca Valero
STREET_NUMBER
1700
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
22802002
CURRENT_STATUS
01
SITE_LOCATION
1700 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
45
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
T 2:91 LEAK TEST METHOD <br /> OUTPUT RELAY SETUP <br /> PRODUCT CODE 2 — — — — — — — — — — — — _ _ _ _ _ _ _ _ _ _ _ _ PMC SETUP <br /> THERMAL COEFF : .000700 TEST ON DATE : ALL TANK, <br /> TANI' DIAMETER 96.00 APR 26. 2020 R 1 :87 PMC VERSION: 01 .04 <br /> TANK PROFILE 1 PT START TIME : DISABLED TYPE: <br /> FULL VOL 12023 TEST RATE :0.20 GAL.:HR STANDARD VAPOR PROCESSOR TYPE <br /> DURATION HOURS VEEDER—ROOT POLISHER <br />� NORMALLY CLOSED <br /> FLOAT SIZE: 4.0 IN. TST EARLY STOP:DISABLED <br /> r WATER MINIMUPM 0.000 ANALYSIS TIMES <br /> E IN—TANK ALARMS <br /> G LEAK TEST REPORT FORMAT TIME: 10:00 AM <br /> T 2:LOW PRODUCT ALARM DELAY MINUTES: 1 <br /> WATER WARNING 1 .5 NORMAL <br /> HIGH WATER LIMIT: 3.0 LIQUID SENSOR ALMS <br /> WATER ALARM FILTER: LOW L 1 :FUEL ALARM <br /> L 2:FUEL ALARM <br /> L 3:FUEL ALARMMAXOR LABEL L 4:FUEL ALARMM <br /> VOLUME 12023 L 5:FUEL ALARM <br /> HIGH PRODUCT L 1 :SENSOR OUT ALARM <br /> L 2:SENSOR OUT ALARM <br /> MAXYo 95.0 L 4:SENSOR OUT ALARM <br /> (GALLONS) 11422 L 5:SENSOR OUT ALARM <br /> OVERFILL LIMIT LIQUID SE19SOR SETUP L 1 :SHORT ALARM <br /> L 2:SHORT ALARM <br /> % MAX 90.0 — — — — — — — — — — — — L 3:SHORT ALARM <br /> (GALLONS) <br /> 2 <br /> 1081 <br /> L 4:SHORT ALARM <br /> L 1 :D I SP 1-2 L 5:SHORT ALARM <br /> DELIVERY LIMIT TRI—STATE (SINGLE FLOAT) <br /> Yo MAX 10.0 CATEGORY : ANNULAR SPACE R 2:91 <br /> (GALLONS) 1202 TYPE: <br /> LOW PRODUCT STANDARD <br /> VOLUME 500 L 2:DISP 3-4 NORNIALL� CLOSED <br /> TRI—STATE (SINGLE FLOAT) <br /> LEAK ALARM LIMIT: 99 C:ATEGOR`! : ANNULAR SPACE IN—TANK ALARMS <br /> SUDDEN LOSS LItMIT: 99 T 2:LOW PRODUCT ALARM <br /> TANK TILT 0.00 <br /> PROBE OFFSET 0.00 LIQUID SENSOR ALMS <br /> L 3:DISP 5-6 L i :FUEL ALARM <br /> TRI—STATE (SINGLE FLOAT) L :FUEL ALARM <br /> SIPHON MANIFOLDED TANKS CATEGORY : STP SUMP L 3:FUEL ALARM <br /> T#: NONE L 4:FUEL ALARM <br /> LINE tMANIFOLDED TANKS L ?:FUEL ALARM <br /> T#: NOME L 4:DISP 7-8 L 1 :SENSOR OUT ALARM <br /> TRI—STATE (SINGLE FLOAT) L 2:SENSOR OUT ALARM <br /> CATEGORY : STP SUMP L 3:SENSOR OUT ALARM <br /> LEAK (MIN PERIODIC: 0% L 4:SENSOR OUT ALARM <br /> 0 L 7:SENSOR OUT ALARM <br /> L 5:87 STP L i :SHORT ALARM <br /> LEAK MIN ANNUAL 0% TRI—STATE (SINGLE FLOAT) L 2:SHORT ALARM <br /> 0 CATEGORY : DISPENSER PAN L 3:SHORT ALARM <br /> L 4:SHORT ALARM <br /> L ?:SHORT ALARM <br /> PERIODIC TEST TYPE <br /> STANDARD i L 6:87 ANNULAR <br /> TRI—STATE (SINGLE FLOAT) <br /> ANNUAL TEST FAIL CATEGORY : DISPENSER PAN <br /> ALARM DISABLED <br /> PERIODIC TEST FAIL f <br /> ALARM DISABLED L 7:91 STP <br /> TRI—STATE (SINGLE FLOAT) <br /> GROSS TEST FAIL CATEGORY : DISPENSER PAN <br /> ALARM DISABLED <br /> SMARTSENSOR SETUP <br /> ANN TEST AVERAGING: OFF — — — — — — — — — — — — <br /> PER TEST AVERAGING: OFF L 8:91 ANNULAR <br /> TRI—STATE (SINGLE FLOAT) s 2:PRESSURE SENSOR <br /> TANK TEST NOTIFY: OFF CATEGORY : DISPENSER PAN CATEGORY VAPOR PRESSURE <br /> TNK TST SIPHON BREAK OFF s 7:CANNISTER <br /> CATEGORY VAPOR VALVE <br /> DELIVERY DELAY 5 N1 I tV <br /> PUMP THRESHOLD 10.00% s 8:ATM PRESSURE <br /> CATEGORY ATM P SENSOR <br />