Laserfiche WebLink
Environmental Health Department <br />Time In: <br />10:00 am <br /> 9:30 am <br />Time Out: <br />Program Element: 3611 - PUBLIC POOL/SPA - PRIMARY <br />Telephone: Owner/Operator: RIVERGATE COMMONS HOA <br />Inspection Type: ROUTINE INSPECTION - Operating Permit <br />Address: 1142 RIVERGATE DR, LODI 95240 <br />Date: 08/08/2023Name of Facility: RIVERGATE COMMONS HOA <br />Swimming Pool Official Inspection Report <br />VIOLATIONS AND CORRECTIVE ACTIONS <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public health <br />and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br /> #10 Disinfectant Residual MAJOR <br />OBSERVATIONS: Free residual chlorine level was 1.0 ppm. Maintain free residual chlorine levels between 2.0ppm and <br />10.0 ppm. Corrected on site. Pool service raised free residual chlorine to 2.0 ppm. <br />CALCODE DESCRIPTION: Public pools, when open or in use, shall be disinfected continuously by approved chemicals and shall maintain <br />the following concentrations: 1.0 ppm to 10.0 ppm free chlorine without cyanuric acid, 2.0 ppm to 10.0 ppm free chlorine with cyanuric acid <br />or 2.0 ppm bromine. Spas, wading pools, and spray grounds shall maintain the following concentrations: 3.0 ppm to 10.0 ppm free <br />chlorine or 4.0 ppm bromine. (CCR 65529) <br /> #24 VGB Suction Covers MAJOR <br />OBSERVATIONS: Main drain suction cover is damaged. Replace/repair suction cover today. Email spec sheet for suction <br />cover replacement to fgarciaruiz@sjgov.org <br />CALCODE DESCRIPTION: All suction outlets shall be equipped with suction covers that meet the applicable ANSI/APSP-16 performance <br />standards. (CBC 3137B) <br /> #3 Safety Signs <br />OBSERVATIONS: "Keep gate closed lacking on both entry gates". Pool service provided sign on main gate. Install "Keep <br />Gate Closed" sign today. <br />CALCODE DESCRIPTION: Pool operator shall keep safety signs well maintained. (CCR 65535) Safety signs shall have clearly legible <br />letters or numbers not less than 4 inches high, unless otherwise specified. Safety signs shall be affixed to a wall, pole, gate, or similar <br />permanent structure in a location visible to all pool users, unless otherwise specified. (CBC 3120B) <br /> #9 Ladders and Handrails <br />OBSERVATIONS: Hand rails on shallow end of pool are loose. Repair/replace hand rails today. <br />CALCODE DESCRIPTION: A means of entry and exit shall be provided at both the shallow and deep end of the pool. Ladders and <br />handrails shall be corrosion resistant and shall be rigidly installed. At least one handrail shall extend from the deck to not less than a point <br />above the top of the lowest step. Handrails shall be installed between 28 to 36 inches above the steps and deck. (CBC 3111B) Pool <br />operator shall keep ladders and handrails well maintained. (CCR 65535) <br />Page 1 of 2EHD 36-01 Rev. 09/16/2020 Swimming Pool OIR <br />FA0000247 PR0360118 SC001 08/08/2023 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD