My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_2023
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
J
>
JACKSON
>
2226
>
2300 - Underground Storage Tank Program
>
PR0548528
>
INSTALL_2023
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/4/2024 2:43:27 PM
Creation date
8/24/2023 12:57:59 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2023
RECORD_ID
PR0548528
PE
2351
FACILITY_ID
FA0000370
FACILITY_NAME
ORLANDOS ESCALON
STREET_NUMBER
2226
STREET_NAME
JACKSON
STREET_TYPE
AVE
City
ESCALON
Zip
95320
APN
22727016
CURRENT_STATUS
01
SITE_LOCATION
2226 JACKSON AVE
P_LOCATION
06
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\lsauers1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
260
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
6. Page FS1.1 General Tank & Line Notes #2 list the 87 tank as 15,000 but the application page 3 of <br />8 list 20,000 gallon tank. Resubmit with clarification. 20k IS CORRECT, CHANGED NOTE <br />a. FS1.1 & FS1.2 Map of underground tanks need clarification. Which fuel tank will be the <br />end tank? It does not match page FS3.0 MODERN WELDING DOES NOT HAVE AN END <br />TANK CHART, THEY SAID IT WAS THE SAME AT THE 10K, THEY USE A 20K TANK AND <br />INSERT A BAFFEL BETWEEN THEM. <br />b. “Fuel Key Notes #2” Please clarify which VeederRoot will be used. <br />7. Page FS3.0 list the 87 unleaded tank as 15,000 gal, page 3 od 8 list the 87 unleaded tank as <br />20,000 gal. Resubmit with clarification. TANK IS 20k SEE PAGE, 3 SEE FS3.0 <br />8. FS2.0 does not list vent sump or equipment. <br />9. What is the longest pipe length? SEE ZONES ON FS.70 COMBINED LENGTH OF EACH ZONE IS <br />GIVEN. <br />10. What is the Ground Water Level? UNKNOWN, CALCS ARE FOR FULL WATER COVERAGE WE <br />EXPECT OVER 30’ BELOW GRADE <br />11. Where are your test ports on both ends (communication)? Vacuum Zones? ADDED TO FS7.0 <br />DETAILS <br />12. Is there any chase piping? Yes added to FS7.0 <br />13. There were two versions of the FS1.1 and FS1.2 sent to me. Clarify the version map that will be <br />used. See revised attached sheets <br />14. Page FS4.0 Section #5 & #2 list the Concrete Slab as 6 inches but the bouncy calculation list top <br />slab thickness as 8.00 inches. Please clarify. Revised to 8”. See detail 11/FS4.1 <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.