EHD Program Facility Records by Street Name
>
M
>
MARCH
>
1243
>
2300 - Underground Storage Tank Program
>
PR0548639
>
INSTALL_2023
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/18/2024 10:04:08 AM
Creation date
9/14/2023 10:11:36 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2023
RECORD_ID
PR0548639
PE
2351
FACILITY_ID
FA0027823
FACILITY_NAME
ARCO AM/PM
STREET_NUMBER
1243
Direction
W
STREET_NAME
MARCH
STREET_TYPE
LN
City
STOCKTON
Zip
95215
APN
10816016
CURRENT_STATUS
01
SITE_LOCATION
1243 W MARCH LN
P_LOCATION
01
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
100
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
OVERALL TANK SLAB VARIES WITH Concrete Slab Specifications NOTES:UST INSTALLATION CLIENT: <br /> NUMBER AND DIAMETER OF TANKS �� <br /> 2• CALIFORNIA VARIANT: CONCRETE SHALL BE NORMAL WEIGHT WITH A MIX OF 1 2 1/2:3 1/2,WITH A MAXIMUM 7 <br /> TYp, 1. CONCRETE SLAB OVER TANKS WITH A MINIMUM 8"THICK FIBER REINFORCEMENT TO BE USED.REINFORCE CONCRETE SLAB AROUND 1/2 GALLONS OF WATER PER SACK.ADD 3.0 LB MARCO(STRUCTURAL)FIBER PER CU.YD. Oi SLOPE CONCRETE AWAY FROM ALL MANHOLES 1"RISE OVER 12"RUN. <br /> MANHOLES WITH(4)#4 REBAR,60"IN LENGTH FOR THE LARGE MANHOLES AND 30"FOR SMALL MANHOLES PLACE REBAR 6°FROM REINFORCING CONCRETE. <br /> SIDES OF BOX.SEE RECIPE BELOW. <br /> 2. THICKEN CONCRETE SLAB AT DISPENSER SUMPS AND TANK FILL AND TURBINE SUMPS SUCH THAT THE BOTTOM OF CONCRETE IS BELOW O CONCREEINFORCEMENT TO BE USED. PREMIX UNIFORMLY THROUGHOUT <br /> iv O THE TOP OF THE TERMINATION OF THE SECONDARY CONTAINMENT OF THE SUMPS PER AB-2481 REQUIREMENTS. REINFORCING STEEL FOR TANK SUMP CAGES SHALL BE4 REBAR. <br /> 3. CONCRETE DRIVE SLAB AT CANOPY FUELING AREA WITH A MINIMUM 6"THICK FIBER REINFORCED CONCRETE TO BE USED.SEE RECIPE MAINTAIN CONCRETE IN A MOIST CONDITION FOR AT LEAST 7 DAYS AFTER PLACEMENT. REINFORCING BARS TO BE NO LESS THAN 2"AND NO MORE THAN 4" <br /> TURBINE AND ATG BELOW 3 FROM SURFACE. <br /> SUMP(TYP.) 4. CONCRETE FORMLESS ISLAND WITH A 6"HEIGHT ABOVE FINISHED GRADE FIBER REINFORCED CONCRETE TO BE USED. PLACE CONCRETE DIRECTLY FROM TRUCK INTO FORMS. DO NOT PUMP CONCRETE UNLESS SPECIAL REINFORCE CONCRETE SLAB AROUND MANHOLES WITH(4)g4 REBAR 60" <br /> SEE RECIPE BELOW. INSPECTION,IN ACCORDANCE WITH CHAPTER 3 OF THE IBC,IS PROVIDED. 4> IN LENGTH FOR LARGE MANHOLES 30"FOR SMALL MANHOLES. PLACE <br /> SUBMIT MIX DESIGNS,WITH STRENGTH AND SHRINKAGE TEST RESULTS,TO OWNER'S ENGINEER AT REBAR 6'FROM SIDES OF BOX. <br /> CONCRETE MIX RECIPE.PREMIX UNIFORMLY THROUGHOUT CONCRETE. REINFORCEMENT BARS TO BE NO LESS THAN 2" LEAST 7 DAYS BEFORE PLACING CONCRETE. USE PEA GRAVEL CONSISTING OF NATURALLY ROUNDED AGGREGATE,MIN " <br /> o AND NO MORE THAN 4"FROM SURFACE. CONSOLIDATE CONCRETE IN PLACE USING A MECHANICAL VIBRATOR. O )6"&MAX OF 4;"IN SIZE,FREE OF CLAY,SLAG,CINDERS,OR DEBRIS. <br /> 1 3 4 UNLESS OTHERWISE NOTED ON THESE DRAWINGS: ALL SUBSTITUTES MUST BE APPROVED BY MANUFACTURER'S&OWNER'S <br /> r` a. CONCRETE - REGULAR WEIGHT HARD ROCK CONCRETE(150 LBS/CU FT) BEFORE PLACING CONCRETE,SECURE REINFORCING STEEL,ANCHOR BOLTS,DOWELS,AND OTHER FIELD REPRESENTATIVE. <br /> z <br /> b. CEMENT TYPE VII.SULFATE RESISTANT INSERTS IN POSITION TO PREVENT MOVEMENT. TANK PAD MINIMUM 2'-0 I- 6 "OFF OUTSIDE WALLS OF TANKS,AND MUSS <br /> >! CONTROL JOINTS TO c. AGGREGATES - ASTM C33,(MAXIMUM SIZE 3/4 INCHES) MATERIALS AND WORKMANSHIP SHALL CONFORM TO A.C.I.-318(SPECIFICATIONS OF THE DESIGN O COVER THE FOOTPRINT OF THE TANKS.REQUIRED TO PROVIDE FOR <br /> BE'TOOLED"WITH d. 28 DAY CONCRETE STRENGTH(f'c): AND PLACEMENT OF CONCRETE). PROPERINTTANK HOLD DOWN,AND TO PREVENT ACCIDENTAL DRILLING <br /> 3/8°RADIUS 4,000 PSI - SLAB (DESIGN BASED ON 2,000 PSI NO SPECIAL INSPECTION REQUIRED) MANHOLE CROWNS: CUT CORNER WHERE MEETING ASPHALT PAVING ONLY. SQUARE <br /> w e. SLUMP - 3"+ 1° -4"MAXIMUM AT POINT OF PLACEMENT ALL MANHOLE OPENINGS ON THE TANK SLAB SHALL BE INSTALLED WITH A 1-1/2"CROWN(1"RISE O CORNERS WHERE MEETING CONCRETE. ARCO m <br /> I. SHRINKAGE - 0.05%MAXIMUM r� <br /> ¢ g. ENTRAINED AIR RANGE-2X TO 4R OVER 12"RUN)OF CONCRETE TO PREVENT WATER INTRUSION INTO THE MANHOLE.THE OWNER'S <br /> S ENGINEER,THE BP PROJECT MANAGER WILL BE REQUIRED TO SIGN OFF ON THIS ITEM ON THE SEE SITE SPECIFIC PLANS FOR ACTUAL TANK SIZES,PLACEMENT,AND <br /> z 42"DIA.FILL& TANK INSTALLATION CHECKLIST. OB ORIENTATION. FINAL SITE SPECIFIC TANK LAYOUTS SHALL BE APPROVED �WW COAST PROpUCIS,LLL` <br /> p VAPOR VAPOR BY THE LOCAL DISTRIBUTION TERMINAL MANAGER OR HIS AGENT. FINAL <br /> 0 RECOVERY SUMP PRODUCT IDENTIFICATION MARKINGS: LOCATION SIGN-OFF SHALL BE DOCUMENTED. NO. DATE DESCRIPTION <br /> WITH STAGE II& CONTRACTOR TO INSTALL PRODUCT IDENTIFICATION TAGS AT ALL MANHOLE OPENING PER SITE <br /> m I VENT(TYP.) SPECIFIC DETAIL DRAWINGS. 1 <br /> z SAWED C060L JOINTS <br /> w ALL MANHOLE ACCESS COVERS <br /> TO BELOW GRADE SHALL BE TANK SLAB SHALL BE THICKENED 8"MIN. FIBER REINFORCED <br /> AT TANK SUMP EXTEND TO WHERE <br /> LIQUID TIGHT AND LOCKABLE TO MONITORING END AT THE SUMP SPECIFICATIONSTB 60VE. O <br /> (TMP') CONCRETE SLAB DESIGN <br /> SEE <br /> In A.C.PAVING 18" 18" 18" 18" <br /> y NOTES: THICKENED (NP.ALL) (TYPJ (NP. (TYP• ALL) (NP.) ) 4,000 P.S.I. 41 28 DAYS <br /> OPENINGS IN SLAB TO HAVE 1-1/2" CONCRETE EDGE PAVINGAl <br /> CROWN <br /> TANK PAD SHALL EXTEND A MINIMUM N.; (; <br /> 2'-0"BEYOND OUTSIDE WALLS OF { v� <br /> p TANKS,AND MM COVER THE ENTIRE w w <br /> FOOTPRINT OF THE TANKS.IN ORDER z - <br /> TO PROVIDE FOR PROPER TANK HOLDT.-T • <br /> MIN.TO <br /> DRLLINGND TO INTO TANK. ACCIDENTAL 3"PEA-GRAVEL PREVENT GLO DLTRANSF R <br /> CHAMFER SLAB CORNERS WHERE MIN.TO PREVENT TO TANK TOPOS <br /> LOAD TRANSFER <br /> MEETING ASPHALT PAVING ONLY. TO TANK TOP #4 AROUND ALL <br /> SQUARE CORNERS WHERE MEETING PENETRATIONS3 4 <br /> �+ O CONCRETE. Q <br /> NOTE: NOTE: SEAL: <br /> q L ALL MANHOLES ON THE TANK SLAB SHALL BE INSTALLED WITH A 1-1/2" CONTRACTOR IS REQUIRED TO THICKEN CONCRETE SLAB AT TANK FILL AND TURBINE <br /> _ CROWN OF CONCRETE TO PREVENT WATER INTRUSION INTO THE MANHOLE. SUMPS SUCH THAT THE BOTTOM OF CONCRETE IS BELOW THE TOP OF THE TERMINATION <br /> 1'-0"CHAMFER 2 8"MIN.FIBER REINFORCED THE OWNER'S ENGINEER WILL BE REQUIRED TO SIGN OFF ON THIS REM OF THE SECONDARY CONTAINMENT OF THE SUMPS PER AB-2481 REQUIREMENTS. NOTE <br /> (TYP.) O CONCRETE SLAB.SEE ON THE TANK INSTALLATION CHECKLIST BEFORE CONTRACTOR WILL BE THAT THE THICKNESS MAY VARY BETWEEN THE FILL AND TURBINE SUMPS AND IS ALSO <br /> 7 DEPENDENT UPON EXISTING SITE CONDITIONS. CONTRACTOR WILL BE REQUIRED TO <br /> SPECIFICATIONS AT RIGHT. PAID. CONTRACTOR WILL BE REQUIRED UI REINSTALL ENTIRE DRIVE SLAB REINSTALL ENTIRE DRIVE SLAB AT OWN EXPENSE IF THIS DESIGN REQUIREMENT IS NOT <br /> CONCRETE SLAB DESIGN AT OWN EXPENSE IF THIS DESIGN REQUIREMENT IS NOT MET. <br /> 4,000 P.S.I.®28 DAYS MET AS DETERMINED BY THE GOVERNING JURISDICTION. '1'F' <br /> 36475 <br /> TYPICAL TANK SLAB REINFORCING SLAB SECTION AT TANKS # P.6-30-2 <br /> IVII- <br /> NOT TO SCALE CF CPU <br /> 1/2"EXPANSION JOINT <br /> CONCRETE IDE AND EDGES OF ISLAND TO JOINT SEALANT INSTALLATION IN PAVEMENT SHALL COMPLY <br /> ISLAND HAVE SMOOTH TOWELED FINISH. ELECTRICAL CONDUIT WITH ASTM C 920 TYPE M,GRADE P, CLASS 25 1/4" RADIUS TOOL EDGE <br /> DESIGN WITH TOP TO HAVE MEDIUM BROOM PETROLEUM RESISTANT SEALANT. USE"SEALTIGHT GARDOX" <br /> 4,000 P.S.I. FINISH POUR CONCRETE WITHIN THE OR EQUAL. 1/2"DEEP INSTALL"SNAP CAP"OR w <br /> ELECTRICAL OFFSET OPENING CAULK WITH "VULKEM 116"OR EQUAL, REMOVE AFTER <br /> STEEL FRAME BETWEEN OTHER SUITABLE HYDROCARBON CONCRETE HAS CUREED AND w <br /> EQ. EQ. DISPENSER SUMP, SEAL WHERE RESISTANT CAULK a v FILL JOINT WITH SEALANT ¢ <br /> � 6 CONCRETE OR CONDUIT MEET z e 'e e' 1/2"EXPANSION JOINT V z m 2 <br /> STEEL. SEAL THE DOWNSIDE OF DISPENSER g e• Z <br /> d ,^OaSIDE'"B" O ° THE SLOPE AND THE CONDUIT a g•• MATERIAL SHALL COMPLY WITH —z m <br /> •d AREA WITH 'YULKEM 116" a¢ ASTM D7751. JOINT FILLER (�O m <br /> DISPENSER >w d CAST IN PLACE m Z_ <br /> BASE MOUNT a a• •o ¢<rL <br /> ••dDISPENSER ISLAND .e o. ° w LL-,O O <br /> A 'p LI_I ¢yLL <br /> 82 <br /> eed• a z0 <br /> a •� d NEW FIBER REINFORCED NEW FIBER REINFORCED a Z 8 i z m <br /> "' OPENING FOR UDC .'' t r .1 SLOPE CONCRETE 44 ' CONCRETE CONCRETE z Z¢z z n <br /> e 1 2"EXPANSION JOINT z <br /> UDC FRAME / PER SPECIFICATIONS PER SPECIFICATIONS z <br /> A. OF SUMP n 1/4"RADIUS TOOL EDGE LLJ z N? <br /> I EXPANSKDN CONSTRUCTION JONf AT NEW PAVEMENT(TYPICAL). 0 i O <br /> s I qE <br /> TALL"SNAP CAP"OR <br /> JOINT SEALANT INSTALLATION IN PAVEMENT SHALL COMPLY AL, REMOVE AFTER NOT TO SCALE w n <br /> • 4 'd _ WITH ASTM C 920 TYPE M. GRACE P, CLASS 25 a CRETE HAS CUREED AND Q CD O <br /> d'a PETROLEUM RESISTANT SEALANT. USE"SEALTIGHT GARDOX" JOINT WITH SEALANT z a <br /> ' e• A+•• JOINT SEALANT INSTALLATION IN PAVEMENT SHALL COMPLY 1/2'JOINT 2 <br /> • OR EQUAL 1/2"DEEP WITH ASTM C 920 TYPE M, GRADE P, CLASS 25 z <br /> .d /2"IXPANSION JOINT PETROLEUM RESISTANT SEALANT. USE'SEALTIGHT GARDOX" 1/4"RDIUS TOOL EDGESIDE"A' v - ATERIAL SHALL COMPLY <br /> ITH ASTM D1751.JOINT OR EQUAL. 1/2"DEEP DEVELOPMENT INFORMATION: <br /> LLER CAST IN PLACE INSTALL"SNAP CAP"OR <br /> NEW PAVEMENT IXISTING PAVEMENT EQUAL, REMOVE AFTER <br /> CONCRETE HAS CUREED AND <br /> 5-0" A W \� FILL JOINT WITH SEALANT <br /> FORMLESS CONCRETE ISLAND PLAN VIEW EXPANSION CONSTRUCTION JOINT AT OWENSER ISLAND(TYPICAL). EINFOR REINFORCED CONCRETE �a g' e: 1/Y EXPANSION JOINT <br /> MATERIAL SHALL COMPLY WITH <br /> NOT TO SCALE DRIVE SLAB. SEE ¢ d ASTM D7751.JOINT FILLER <br /> SCALE: 1"=1'-0" SPECIFICATIONS ABOVE. a a• 'd CAST IN PLACE <br /> e ° DRILL EXISTING CONCRETE SITE ADDRESS <br /> 1/2"EXPANSION JOINT FOR DOWEL PLACEMENT ADDM <br /> 1/4"RADIUS TOOL EDGE 3/4"DIA.X 18'L.GREASED OR 26WESTMMCHLAIE <br /> COATED STEEL DOWEL® 18"O.C. TROCKIM CA OU <br /> INSTALL"SNAP CAP"OR EQUAL, <br /> 1"TOOLED RADIUS (TYP.) 1"TOOLED RADIUS(TYP. REMOVE AFTER CONCRETE HAS <br /> ftRA- CUREED AND FILL JOINT WITH EXPANSKON JOINT AT NEW AND EXISTING PAVEMENT(TYPICAL) <br /> OPENING FOR CAST IN UDC MINIMUM HEIGHT NOT TO EXCEED SEALANT NOT TO SCALE DESIGNED BY: <br /> CENTERED IN ISLAND 6"UNLESS APPROVED BY OWNER 1/2"EXPANSION JOINT MATERIAL <br /> SHALL COMPLY WITH ASTM D1751. JOINT SEALANT INSTALLATION IN PAVEMENT SHALL COMPLY CHECKED BY. <br /> JOINT FILLER CAST IN PLACE WITH ASTM C 920 TYPE M, GRADE P,CLASS 25 DRAYM BY: ER <br /> A. _ _ PETROLEUM RESISTANT SEALANT. USE "SEALTIGHT GARDOX" SAWED JOINT 1/4"X 2"DEPTH <br /> .e d ',• a' _ OR EQUAL 2"DEEP WITH FLARED EDGE EASIER 04)14)2021 <br /> DATE: PROJECT NO. <br /> e d. 7161 <br /> I °I d a. DRAWING TITLE: <br /> ' '.d e d aTANK SLAB CONCRETE SPECIFICATIONS <br /> e.a4 a AND IDENTIFICATION MARKING DETAILS <br /> 5'-0" D- ,a d e � SHEET NO: <br /> 6'MIN. FIBER REINFORCED c. o d <br /> CONCRETE DRIVE SLAB. SEE <br /> SPECIFICATIONS ABOVE. .a <br /> FORMLE98 CONCRETE BLAND 5-0' SECTION FOFiAALE88 CONCRETE U9LAND 3'-0" SECTION <br /> M.5.3.26 <br /> SCALE: 1"=1'-0" SCALE: 1"=1'-0" <br /> CONTROL JOINT(AWED) O NOTE: INDICATES ITEMS FOUND ON <br /> NOT TO SCALE XX MATERIALS LIST SHEET M.5.3.01 & M.5.3.02 <br />