COMPLIANCE INFO_2023
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
ATHERTON
>
1222
>
2300 - Underground Storage Tank Program
>
PR0547926
>
COMPLIANCE INFO_2023
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/10/2023 12:07:28 PM
Creation date
9/14/2023 10:14:36 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2023
RECORD_ID
PR0547926
PE
2351
FACILITY_ID
FA0027325
FACILITY_NAME
CHEVRON #385102
STREET_NUMBER
1222
Direction
W
STREET_NAME
ATHERTON
STREET_TYPE
DR
City
MANTECA
Zip
95337
APN
22616041
CURRENT_STATUS
01
SITE_LOCATION
1222 W ATHERTON DR
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
97
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Overfill Prevention Equipment Inspection <br /> .114Tanknology OPW 61 and 71 Series Overfill Prevention Device Inspection <br /> Date: 8/7/2023 <br /> Customer Name: Jones covey Group, Inc. <br /> Location#: CHEVRON 99280 <br /> Location Address: 1222 W Atherton ,Manteca ,CA, 95337 <br /> OPW Model Number: 71 SO <br /> REGULAR PREMIUM DIESEL <br /> PART 1)Proper height setting calculation <br /> Maximum Tank Volume per:Tank Chart Agallons 19782.000 15041.000 11904.000 <br /> Max shut off requirement for Flapper is 95% a 95% 0.95 0.95 0.95 0.95 <br /> Multiply Maximum tank volume by 95% c gallons 18792.900 14288.950 11308.800 <br /> Use tank chart to determine height of calculated volume D inches 103.000 104.750 101.125 <br /> Measure top of fill riser threads,or face seal adapter when used,to tank top E inches 43.500 44.750 48.000 <br /> Tank diameter From Chart Finches 118.380 118.380 118.380 <br /> Upper Tube in tank(G) F-D=G G inches 15.380 13.630 17.255 <br /> Subtract 2 inches from upper tube in tank G-2"=H H inches 13.380 11.630 15.255 <br /> Calculated minimum upper tube length(1)H+E=I i inches 56.880 56.380 63.255 <br /> Actual measured upper tube length (Without fill J inches 56.875 56.375 63.250 <br /> adapter)(J) <br /> PART 2)Device certification criteria evaluation <br /> Criteria 1 Yes Yes Yes <br /> Does the overfill prevention device meet the 95%requirement? <br /> Criteria 1 a If the final shutoff volume is installed greater than 95%,is there at <br /> least 250 gallons of ullage above the overfill device activation point NA NA NA <br /> to ensure that none of the tank top fittings are exposed to product, <br /> meeting the criteria established in EPA 280.20iic and per OPW <br /> installation guidelines. <br /> Criteria 2 Is the Actual measured upper tube length 6.5 inches Yes Yes Yes <br /> or more than the fill riser?(J must be 6.5"or more <br /> than E) <br /> Criteria 3 Does the overfill prevention device function as <br /> required?(Inspect the device for damage, Yes Yes Yes <br /> contamination,freedom of movement, <br /> weakening due to wear and corrosion) <br /> PART 3)Device Certification PASS/FAIL <br /> Pass Pass Pass <br /> Technician certifies that the device is operationally <br /> compliant. <br /> Comments: <br /> Signature of Technician: Date: 8/7/2023 <br /> Landon Zamora <br /> WO: NW1-2363644 <br />
The URL can be used to link to this page
Your browser does not support the video tag.