Site ID/Name: 385102 CHEVRON 99280 NW1-236374808/28/2023 <br /> Address: 1222 W Atherton, Manteca, CA 95337 <br /> ARRgndbc BB <br /> 71 SO Overfill Vahre in Tank Shut off Level Worksheet <br /> Imoartant: This is meant to be supplemental worksheet and not a substitute to following the Installation <br /> manual instructions. All length measurements are In Inlches. Please contact the Authority Harting Jurisdic- <br /> tion(AIHU)and review local,state,and national codes to determine the regulatory requirements governing <br /> shut-off capacity in your reg Ion,as well as take into account other considerations such as extreme tank tilt. <br /> Tank ID: DIESEL(Biodiesel) <br /> Take the following measurements with the valve in- <br /> stalled in the tank: <br /> Distance from tha 7150 inlet tube flange to the cast <br /> lug In the 7150 body(see figures),upper tube length. <br /> Note; the Upper Tube Length must be at least 16"to <br /> include the protective bend in the tube. <br /> (D)= 63.125 <br /> Distance from the 71 SO inlet tube flange to the top and <br /> bottom of louver tube,valve length. (D) <br /> (V)= Upper <br /> (U)= Tube <br /> Distance from the 71 SO inlet tube flange to the bottom <br /> of the tank. Note:If a tank bottom protector Is present it <br /> may be necessaryto add this thickness to dimension <br /> (OPW 6111 &61TP models add 0.69 (4Y}Value <br /> (g)= 170_ _ tngth, <br /> bottom of <br /> From the tank calibration chart provided by tank manu- _ cut <br /> facturer fired the dipstick number(Y)which corresponds <br /> to the 100%vol ume. (B) <br /> (y')= 11904 To Tank <br /> (1') <br /> 1. To doWnnine shut-off percentage: Tank <br /> Subtract Upper tube length(D)from distance to tank (U)Valve Chart <br /> bottom(B) Length, 100%Vol- <br /> _(B)_(D)-20= 104.875 top of cut urne DEp- <br /> stick <br /> Using the tank calibration chart provided by the tank <br /> manufacturer determine the tank capacity at the cal- <br /> culated(X)dimension and the 1O n volume(Y}tank <br /> capacity. <br /> (X)tank capacity In gallons= 11237 <br /> {ll')tank capacity In gallons= 11904 <br /> SO%=(K)capacity/(Y)capacity x100= 94.3 <br /> f4ote: The overfillvalve must he Installed per AHJ require- <br /> ments and all applicable local,Aae,and national codes. if <br /> the overfill valve is set above the allowable shut-off percent- <br /> age the overfill valve must be removed and rep Iamd. for <br /> reference 40 CFR.part 280 Subpart B Section 290.20 overfill <br /> valves should be set to a maximum of 95%. <br /> 20 <br />