GENERAL DEMOLITION NOTESBAFEDCDEMOLITION WORK SHALL BE EXECUTED IN CONFORMANCE WITH THE LOCAL BUILDING CODE AND LANDLORD'S STANDARD PROCEDURES.FIELD VERIFY ALL EXISTING CONDITIONS AND NOTIFY ARCHITECT OF ANY DISCREPANCIES IN WRITING PRIOR TO ONSET OF DEMOLITION.EXERCISE EXTREME CAUTION IN DEMOLITION, COST OF REPAIR TO ANY ADJACENT CONDITIONS DAMAGED AS A RESULT OF THIS DEMOLITIONSHALL BE THE RESPONSIBILITY OF THE CONTRACTOR.ALL MATERIAL TO BE DISPOSED OF IS TO BE DONE BY THE CONTRACTOR OFF THE PROJECT SITE IN ACCORDANCE WITH L.L. REQUIREMENTS &LOCAL RESTRICTIONS UNLESS OTHERWISE NOTED HEREIN.ALL AREAS SHALL BE KEPT IN A BROOM CLEAN CONDITION AT ALL TIMES.IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE ALL EXISTING UTILITIES WHETHER SHOWN HEREIN OR NOT, AND TOPROTECT THEM FROM DAMAGE. THE CONTRACTOR SHALL BEAR ALL THE EXPENSES OF REPAIR OR REPLACEMENT OF UTILITIES OR OTHERPROPERTY DAMAGE BY OPERATIONS IN CONNECTION WITH EXECUTION OF THE WORK . INACTIVE OR ABANDONED UTILITIES SHALL BE CAPPEDIN ACCORDANCE WITH LOCAL RESTRICTIONS, REMOVE INACTIVE SERVICES (PLUMBING, ELECTRICAL, MECHANICAL, ETC.) AS REQUIRED TOMAINTAIN OPERATION.HGJIPROTECT ALL STRUCTURAL MEMBERS FROM DAMAGE, AND BRACE ALL EXISTING STRUCTURES AS NEEDED DURING THE DEMOLITION.MAINTAIN COMPLETE SECURITY OF THE JOB SITE WHILE JOB IS IN PROGRESS AND UNTIL JOB IS COMPLETE.DO NOT CUT ON EXISTING STRUCTURAL WORK IN A MANNER RESULTING IN A REDUCTION OF LOAD CARRYING CAPACITY OR LOAD/DEFLECTIONRATIO. NOTIFY LANDLORD REP. OF ALL STRUCTURAL PROPOSED CUTS PRIOR TO EXECUTION TO OBTAIN APPROVAL.IN ALL AREAS WHERE DEMOLITION CAUSES UNEVENNESS IN THE FLOOR SLAB, PERFORM THE NECESSARY WORK REQUIRED TO PROVIDE ASMOOTH SLAB PREPARED TO RECEIVE NEW FINISHES.ANY EXISTING TO REMAIN FIRE ASSEMBLIES DAMAGED DURING DEMOLITION SHALL BE REPAIRED TO MEET ORIGINAL FIRE PROTECTIONREQUIREMENT.LIT WILL BE THE GENERAL CONTRACTORS RESPONSIBILITY TO COORDINATE WITH LANDLORD ON-SITE OPERATIONS DIRECTOR AND TENANTBELOW, BEFORE BELOW SLAB WORK IS TO BE DONE.KMIT WILL BE THE GENERAL CONTRACTORS RESPONSIBILITY TO COORDINATE ANY WORK ON THE FIRE SUPRESSION, FIRE ALARM, OR SAFETY SYSTEM WITH OWNER AND WALMART. SPRINKLER, STRUCTURAL, FIRES ALARM, AND FIRE SUPPRESSION DRAWINGS BY OTHERSDEMOLITION NOTES1GENERAL CONTRACTOR SHALL REMOVE EXISTING NONBEARING PARTITION WALLS AS INDICATED. DISCONNECT AND REMOVE ALL EXISTINGELECTRIC, CAP OFF PLUMBING (IF ANY) WITHIN REMAINING WALLS OR ABOVE CEILING, AS REQUIRED. PATCH AND REPAIR REMAINING WALL,CEILING, AND FLOOR SURFACES TO ACCEPT FINISHES AS INDICATED.1A2GENERAL CONTRACTOR SHALL REMOVE PORTION OF EXISTING INTERIOR LOW WALL. THE REMAINING OF THE EXISTING LOW WALL SHALLREMAIN, SEE FLOOR PLANGENERAL CONTRACTOR SHALL REMOVE EXISTING TILE FLOOR FINISHES IN DINING ROOM AND RESTROOMS, CLEAN AND REPAIR EXISTINGCONC. SLAB TO RECEIVE NEW FINISHES PER FLOOR FINISHES PLAN.GENERAL CONTRACTOR SHALL VERIFY CONDITION OF EXISTING QUARRY TILE FLOORING IN KITCHEN AND PREP AREA TO BE REUSED, INSTALLNEW QUARRY TILE AS REQUIRED, SEE FLOOR FINISH PLAN.3GENERAL CONTRACTOR SHALL REMOVE EXISTING CEILING LIGHT FIXTURES AND FANS IN DINING ROOM, SEE REFLECTED CEILING PLAN FORNEW CEILING AND LIGHTING CONFIGURATION.GENERAL CONTRACTOR SHALL VERIFY CONDITION OF EXISTING SUSPENDED CEILING TILE/ LIGHT FIXTURES IN KITCHEN AREA. REPLACE ASREQUIRED.4EXISTING A/C UNIT TO REMAIN, REUSE EXISTING DUCTWORK , SEE SHEET M1.0 FOR MODIFICATION TO EXISTING HVAC SYSTEM.EXISTING SERVICE DOOR TO REMAIN.EXISTING STOREFRONT GLASS WINDOWS AND DOORS TO REMAIN.REMOVE EXISTING STOREFRONT METAL AWNING FRAME.EXISTING ELECTRICAL POWER SUPPLY TO REMAIN, SEE ELECTRICAL DRAWING.EXISTING RESTROOM DOORS TO REMAIN, SEE DOOR SCHEDULE FOR FINISHES.9REMOVE EXISTING DINING ROOM FIXTURES, SALES COUNTER , MILWORK AND METAL POLES.EXISTING MOP SINK TO REMAIN, RESTORE TO LIKE NEW CONDITION. SEE PLUMBING DRAWING.121314151616REMOVE HAND SINK PLUMBING PIPING AND FURRED WALL.VERIFY CONDITION OF ALL WALL FINISHES FRP IN KITCHEN , COORDINATE WITH OWNER FOR REPLACING FRP WITH NEW.COORDINATE WITH OWNER AND REMOVE EXISTING HOOD, DUCT WORK AND ROOF FANS.REMOVE DINING ROOM TILE FINISHES. INSTALL NEW FINISHES PER INTERIOR ELEVATIONS.REMOVE PREP AREA TILE FINISHES. INSTALL NEW FINISHES PER INTERIOR ELEVATIONS.EXISTING WALL BRICK FINISH TO REMAIN, RESTORE BRICK TO LIKE NEW CONDITION.COORDINATE WITH OWNER AND REMOVE EXISTING CO2 TANK.REMOVE PORTION OF EXISTING SOFFIT, SEE REFLECTED CEILING PLAN FOR NEW SOFFIT CONFIGURATION.EXISTING FLOOR RECESSED GREASE INTERCEPTOR TO REMAIN, VERIFY CONDITION AND CODE COMPLIANCE. RESTORE TO LIKE NEWCONDITION.EXISTING WATER HEATER TO BE REMOVED, INSTALL NEW GAS WATER HEATER PER PLUMBING PLANS.17181920111086A653A2A(PLAN NOTES -REFERENCE ONLY AS NOTED ON PLANS)1GC TO MAINTAIN EXISTING ELEC. PANELSEXISTING QUARRY TILE TO REMAIN, GC TO PATCH, REPAIR, CLEAN, AND BRING TO A LIKE-NEW FINISHEXISTING DINING TILE IN LOBBY AREA TO REMAIN, GC TO REPLACE DAMAGED TILES, CLEAN, AND BRING TO A LIKE-NEW CONDITIONLINE OF FLOOR TRANSITION TO BE PATCHED AND MATCH EXISTING FOR NEW COUNTEREXISTING HAND SINK TO REMAINEXISTING 3-COMP SINK TO REMAINEXISTING MOP SINK TO REMAINEXISTING DOOR TO BE REMOVED11LINE OF EXISTING HEADER ABOVELINE OF EXISTING HEADER ABOVEEXISTING FLY LIGHT TO REMAIN1. TENANT PROPOSES BELOW SLAB PLUMBING WORK. TENANTSHALL REPLACE ANY BASE MATERIAL AND COMPACT TOMATCH EXISTING. MATCH FLOOR SLAB THICKNESS AND FINISHWITH 4,000 PSI CONCRETE. REF STRUCT. --TENANT SHALLFIRST DO TEST DEMOLITION OF SLAB OF NO MORE THAN 5SFTO CONFIRM THAT THE EXISTING SLAB CONDITION IS NOT ASTRUCTURAL SLAB. IF THE EXISTING SLAB CONDITION IS ASTRUCTURAL SLAB TENANT SHALL IMMEDIATELY STOPUNDERSLAB WORK AND PROVIDE SLABPENETRATION/REMEDIATION DRAWINGS TO WALMART BY ALICENSENED STRUCTURAL ENGINEER, LICENSED IN THE STATEIN WHICH THE TENANT WORK IS TAKING PLACE.2. NO ROOF STRUCTURAL MEMBERS SHALL BE REMOVED ORDAMAGED DURING THE TENANT SPACE DEMOLITION.WALMART DEMOLITION NOTESEXISTING LIGHT TO BE RELOCATED "E2", TYP.CEILING AND GRID TO BE REMOVEDEXISTING LIGHT TO BE DEMOLISHED "D1", TYP.CEILING AND GRID TO BE REMOVED FOR NEW HOODEXISTING SUPPLY REGISTER, TYP.EXISTING RETURN REGISTER, TYP.EXISTING SOFFIT TO BE REMOVEDEXISTING 2'X4' FLUORESCENT LIGHT, TYP.E2E2E2E2D1CEILING AND GRID TO BE REMOVEDEXISTING SOFFIT TO BE REMOVEDEXIST ACT 13' - 11"EXIST ACT 9' - 7 3/4"B.O. SOFFIT 9' - 3"EXIST VCT 10' - 0"EXIST VCT 10' - 0"B.O. HEADER 8' - 1"EXIST ACT 13' - 11"17' - 0"10' - 11"SPRINKLERS IN REMOVED CEILING TO BE COORDINATED BY GC.It is the responsibility of the ConstructionManager/General Contractor and allSub-Contractors to verify all dimensions andaccept conditions of prior work by relatedtrades before proceeding with any work.DateDrawn ByScaleSeal:Project TitleProject AddressProject NumberDrawing Title and NumberMAIN OFFICE:1 HUNTINGTON QUADRANGLESUITE 2C03MELVILLE, NY 11747P: 631.226-7700 F: 631.226.7175Issued:Check ByOwner:AS SHOWNSTAFFCM© Copyright 2018: RGBK, INC.CharleysRobert Cheung2043 Limewood Drive,San Jose, CA 95132Stockton, CAWM15543223 E Hammer Ln,Stockton, CA 95212WM1554DEMOLITION PLANSA0.407-22-2021SCALE: 1/4" = 1'-0"3Demolition PlanSCALE: 1/4" = 1'-0"5Demolition Ceiling PlanRev.No.DescriptionDateIssued for Permit08-23-2021
|