Laserfiche WebLink
LIGHTING FIXTURE SCHEDULETYPEASYMBOLDESCRIPTIONCAGED PENDANTMANUFAC.NUVOLIGHTINGCATALOGNUVO-60-5401LAMPINCANDESCENTA19MTG.PENDANTVOLT120REMARKSMOUNT AT 6'-4" A.F.F.LAMPS/FIXT.1BOCKBC1C2D18"Ø DECORATIVE PENDANTLIGHTINGFLOOD PENDANT LIGHTRED DOT /HUBBELLFLOOD PENDANT LIGHTDIRECTIONALRECESSED DOWN LIGHTJUNOIC22LED G4 14LM 4000K90CRI 120 ZT24 WWH TRIME2X4 FLAT PANEL TROFFERMAXLITEMLFP24EP4050S500EG /141503P187-CS18DLMED5-E26PENDANT120MOUNT AT 6'-4" A.F.F.BALLASTSELECTRONICBALLAST/FIXT.WATTTOTAL40113PAR30/LED/40'/3000K/120SATCOS9431LED20.3 WATT LEDELECTRONIC5PENDANT120PROVIDE JB @ STRUCTURE AND SUSPENDFIXTURE WITH 1/2" RIGID CONDUIT. CONFIRMMOUNTING HEIGHT WITH OWNER.RECESSED12010%-100% DIMMINGLED (40W) 5000LUMENGEXEM/EXGEXTERIOR LED ROPE LIGHTELECTRIC ZONEOR EQUALEXIT LIGHTATLITEEZ5050IP68-HV120V-60WLE1.21 W / FT.DWHITEPNLRUFURNISHEDW/UNITLED EXIT/EMERG COMBO LIGHTVAOPTO LED ORLITHONIAPN # VO-EMX-R1LHQM S W 1 R 120SELF POWERED LEDFURNISHEDW/ UNITRECESSED120PROVIDE ALL REQ'D. HARDWARE0-10V DIMMING10%-100% DIMMINGRECESSED120PROVIDE ALL REQ'D. HARDWARE165 FEET REEL LENGTHUNIVERSALUNIVERSAL12090 MINUTE BATT. BACKUP POWER12090 MIN. NICKEL CADMIUMBATT BACK UP POWERN/AN/AIMPACT RESISTANT THERMOPLASTICHOUSING HOUSING WITH SELF -CONTAINEDPOWER PACKN/AN/A1ELECTRONIC131120.31ELECTRONIC1401.21/FT55.4E12X4 FLAT PANEL TROFFERE22X4 FLAT PANEL TROFFERLED (40W) 5000LUMENLED (40W) 5000LUMENRECESSED1201ELECTRONIC140RECESSED1201ELECTRONIC140EXIST.EXIST.--EXISTING TO REMAINEXISTING TO BE RELOCATEDREFLECTED CEILING PLAN CONSTRUCTION NOTES200201202203GENERAL CONTRACTOR SHALL PROVIDE AND INSTALL 5/8" TYP. "X" GYP. BD. CEILING/SOFFITS AND PAINT PER REFLECTED CLG. PLAN, SECTIONS, AND ELEVATIONS.EXISTING SUSPENDED CEILING TO REMAIN. AS REQUIRED, GENERAL CONTRACTOR SHALL PROVIDE AND INSTALL 2'X4' LAY-IN CEILING SYSTEM AS INDICATED ONREFLECTED CEILING PLAN. THE ENTIRE PERIMETER MUST BE SILICONE CAULKED WHERE GRID MEETS WALL.COORDINATE WITH OWNER AND SIGN VENDOR FOR NEW STOREFRONT SIGN INSTALL, ALL SIGNAGE TO BE APPROVED UNDER SEPARATE SUBMISSION BY SIGNMANUFACTURER.MECHANICAL DIFFUSERS SEE M-1 FOR EXTENT OF MECHANICAL WORK.ATTACH TO STRUCTURE ABOVE3-5/8" MTL BRACING @ 16" o.c.3-5/8" 20 GA MTL FRAMING @ 16" O.C.SECURE TO STRUCTURE ABOVE3-5/8" MTL BRACING @ 16" o.c.3-5/8" MTL BRACING @ 16" o.c.EXISTING INTERIOR WALL2'-4"1 LAYER 58" GYPBD ON 3-5/8"MTL. STUDS @ 16" O.C.Scale: 3/4" = 1'-0"ATTACH TO STRUCTURE ABOVE1 LAYER 5NEW 2'X4' TILE CEILING1 LAYER 58" GYPBDON 3-5/8" MTL.STUDS @ 16" O.C.MENU BD. BY SIGNAGE VENDOR.7'-0" A.F.F.BOTT. OF MENU BD.Scale: 3/4" = 1'-0"2X FRT WOOD BLOCKING AS REQUIRED2X FRT WOOD BLOCKING AS REQUIRED10'-0" A.F.F.SUSPEND CEILINGINDUSTRIAL PIPE MOUNTING HARDWARE.8" GYPBD ON 3-5/8"MTL. STUDS @ 16" O.C.(4) 55" MONITORS,PROVIDE POWEREXHAUST HOOD CANOPY -REFER TO HOOD DRAWINGSGC TO MAINTAIN ROOF WARRANTY AND TYPE DUE TO INSTALLATION OF NEW EXHAUST FAN. REINFORCE JOISTS AS REQUIRED FOR NEW OPENINGEXISTING VINYL CLAD GYP TILE CEILINGTO BE MAINTAINED, GC TO COORDINATE NEW WALLS, TYP.EXISTING WALK-IN CEILING AND LIGHTING TO REMAINCOORDINATE PENDANT LIGHTS OVER TABLES, TYP.EXISTING CEILING TO BE MAINTAINED, GC TO COORDINATE NEW WALLS, TYP.WALMART ENTRANCEREFERENCE LIGHTING PLAN FOR EMERGENCY LIGHTING AND EXIT SIGNSGC TO VISIT THE SITE TO CONDUCT INVESTIGATION FO REUSING DUCT PERFORATIONS FOR NEW KITCHEN EQUIPMENT -REPORT ANY DESCREPANCY TO THE DESIGN PROFESSIONAL OF RECORD(202)LIGHT FIXTURES TO BE RELOCATED 'E2', TYP.(1) 55" MONITOR,PROVIDE POWERAND DATAEXIT SIGN -SEE LIGHTING PLANSEXIT SIGN -SEE LIGHTING PLANSE2E2E2E2E1E1E1E1E1E1E1E1E1E1E1E1E1E1E1E1E1E1E1E1E1E1E1E1E1E1E1E13' - 6"3' - 6"2' - 0"1' - 6"DDDE5E5E5E5E7B.O. SOFFIT 9' - 3"EXIST VCT 10' - 0"B.O. HEADER @ 6' - 8"EXIST ACT 13' - 11"EXIST VCT 10' - 0"B.O. HEADER 8' - 1"EXIST ACT 13' - 11"AAAAAAAAAA8' - 6"TYP.3' - 0"9' - 0"TYP.2' - 0"20' - 3"6' - 6"6' - 6"6' - 6"8' - 0"3' - 8"2A1.217' - 0"9' - 0"7' - 10"3' - 2"ACT 13' - 11"It is the responsibility of the ConstructionManager/General Contractor and allSub-Contractors to verify all dimensions andaccept conditions of prior work by relatedtrades before proceeding with any work.DateDrawn ByScaleSeal:Project TitleProject AddressProject NumberDrawing Title and NumberMAIN OFFICE:1 HUNTINGTON QUADRANGLESUITE 2C03MELVILLE, NY 11747P: 631.226-7700 F: 631.226.7175Issued:Check ByOwner:AS SHOWNSTAFFCM© Copyright 2018: RGBK, INC.CharleysRobert Cheung2043 Limewood Drive,San Jose, CA 95132Stockton, CAWM15543223 E Hammer Ln,Stockton, CA 95212WM1554REFLECTED CEILINGPLANS AND NOTESA1.207-22-20211GYP. BD. SOFFIT SECTION2MENU BOARD SOFFIT DETAILSCALE: 1/4" = 1'-0"3Reflected Ceiling PlanRev.No.DescriptionDateIssued for Permit08-23-2021